BLX PositionersDependable Products Responsive Service BLX V100 SeriesMaintenance friendlyThe BLX pilot valve assembly can becleaned by removing one screw andcan only be installed one way the correct gauge block is standard I/P test point facilitates positionerloop testingFlexibilityOne housing forpneumatic orelectropneumaticThe I/P can be installedor removed at any timeMultiple mountingcapabilityStandard indicator allowsfor air to open or air toclose operationFlat or raisedindicator availableF05 standard housingwith CalibrationWith the non-interactivespan and zero adjustment,and the external zeroadjustment, calibration issimple and time of experience have helped Introducing the BLX V100P and V100E new line of pneumatic and electropneumatic Positioners incorporates oversixty years of design, manufacturing, and marketing experience, creating one ofthe most durable, reliable instruments on the cams, rangesprings, various NEMA ratings, and feedbackcapability are componentsof the BLX aluminum,Polyester coatedhousing Stainless steelretained fasteners Double lockedstainless camQuality metalinternal parts develop this complete positioner .

Maintenance friendly The BLX pilot valve assembly can be cleaned by removing one screw and can only be installed one way— the correct way. The gauge block is standard

Tags:

  Positioner, Blx positioners

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of BLX Positioners - flowsysinc.com

1 BLX PositionersDependable Products Responsive Service BLX V100 SeriesMaintenance friendlyThe BLX pilot valve assembly can becleaned by removing one screw andcan only be installed one way the correct gauge block is standard I/P test point facilitates positionerloop testingFlexibilityOne housing forpneumatic orelectropneumaticThe I/P can be installedor removed at any timeMultiple mountingcapabilityStandard indicator allowsfor air to open or air toclose operationFlat or raisedindicator availableF05 standard housingwith CalibrationWith the non-interactivespan and zero adjustment,and the external zeroadjustment, calibration issimple and time of experience have helped Introducing the BLX V100P and V100E new line of pneumatic and electropneumatic Positioners incorporates oversixty years of design, manufacturing, and marketing experience, creating one ofthe most durable, reliable instruments on the cams, rangesprings, various NEMA ratings, and feedbackcapability are componentsof the BLX aluminum,Polyester coatedhousing Stainless steelretained fasteners Double lockedstainless camQuality metalinternal parts develop this complete positioner .

2 Dependable design supported with excellent electricalcompartment, fittedwith an o-ring, ispressure sealed bythe cover Technical SpecificationsV100PV100 EInput range:3-15 PSI (20-100kPa)4-20 mA (R1<25ohms)Supply pressure:<145 PSI (<1 MPa) PSI ( )Linearity error:< < :< < :< < Gain:@87 PSI (600kPa)750 Pout / Pinacc. to ISA Pout / %PinAir Capacity:SCFM(SLPM)@29 PSI (200kPa) (270)@87 PSI (600kPa) (800)@145 PSI (1 MPa) (1350)Bleed Rate:SCFM(SLPM)SCFM(SLPM)@29 PSI (200kPa) (5) ( )@87 PSI (600kPa) (15) ( )@145 PSI (1 MPa) (25) ( )Temp range:-40 to 185 Fahrenheit-40 to +85 CelsiusAir connectors:1/4" NPTG auges:1/8" NPT(optional G threads)Cable entry:1/2" NPT (optional or PG )Ingress & corrosion protection:NEMA 4X and IP66 Coating:Powder lbs ( ) lbs ( )Weight with lbs ( ) lbs ( )Options:Feedback Spring for 6-30 PSI (40-200kPa) input camsPilot Valves:Type W1 for better stability and lower bleed.

3 Pressure gain @ 87 PSI = 300 Bleeds 33% less but has 10% less air capacity than standard valve W3 Type W2 for faster response and better accuracy. Pressure gain @ 87 PSI > 1000 Has same air capacity but bleeds 33% more than standard valve specifications are based on Type W3 as the standard pilot CodesPositioner TypeDrive Front CoverIndicator CamV100P-PneumaticD1-Namur90-90 degreeA-arrowC1-Standard-90 E-Electropneumatic D2- 1/2" square60-60 degreeB-raisedC2-45 & 90 EX-Explosion Proof (others available)45-45 degreeC3-60 & 30 FF-Fail Freeze30-30 degreeC4-120 & 60 Example: V100E-D1-90-B-C1 Electropneumatic positioner , with namur drive, 90 cover, raised indicator, and standard 90 >0<3 1/2" [89mm]6 11/32" [161mm]4 11/32" [110mm]5/16" [8mm]7/16" [11mm]6 5/8" [168mm]1/8" [4mm]1 9/16" [40mm]7 1/2" [191mm]6 7/16" [163mm]C-C+SIPI1 13/32" [ ]2 3/4" [70mm]9/16" [14mm]1 5/8" [ ]2 11/16" [ ]3 15/16" [100mm]1 3/16" [ ]17/32" [ ]3/4" [19mm]7 1/2" [191mm]3 3/16" [ ]3 1/2" [89mm]3 3/4" [95mm]2 5/16" [59mm]1 7/8" [ ]1 13/32" [ ]VALVE ACCESSORIES & CONTROLS, LLC12585 Old Highway 280 East Suite 101 Chelsea, AL 35043 TEL: 205-678-0507 FAX: Distributed by:Marketed by VAC(Valve Accessories &Controls, LLC.)

4 , theBLX positioner linewill be supported bya knowledgeable andprofessional service isa keycomponent tothe BLX/VAC pack-age. Local invento-ries and technical assistanceare just a phone call BLX product packagewill include a diverse mix ofpositioners, rack and pinionactuators, and feedbackswitches for positionermounting and/or standalone use, as well as an I/Ptransducer. Quality designand manufacturing will becoupled with very competitivepricing and excellent service,providing all process indus-tries a complete package .12/01-4m