Bosch Group24i RSFWALL MOUNTED COMBINATION Boiler FOR CENTRAL HEATINGAND MAINS FED DOMESTIC HOT WATERINSTALLATION ANDSERVICING INSTRUCTIONSGC 47 311 47 311 38 Boiler OUTPUTTo Domestic Hot Water Modulated ControlMinimum kW (25,600 Btu/h)Maximum kW (80,000 Btu/h)To Central Heating Modulated Control\Auto Range RatedMinimum kW (25,600 Btu/h)Maximum kW (80,000 Btu/h)THESE INSTRUCTIONS APPLY IN THE UK ONLYTHESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE GAS METERThis appliance must be installed by a competent person in accordancewith the Gas Safety (Installation and Use) Regulations Gas Safety (Installation and Use) Regulations, October 1994all gas appliances must be installed by a competent person inaccordance with the above regulations.

bosch group 24i rsf wall mounted combination boiler for central heating and mains fed domestic hot water installation and servicing instructions gc numbers

Tags:

  Group, Boiler, Bosch, Bosch group 24i rsf

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Bosch Group 24i RSF - Orpington Boiler Company

1 Bosch Group24i RSFWALL MOUNTED COMBINATION Boiler FOR CENTRAL HEATINGAND MAINS FED DOMESTIC HOT WATERINSTALLATION ANDSERVICING INSTRUCTIONSGC 47 311 47 311 38 Boiler OUTPUTTo Domestic Hot Water Modulated ControlMinimum kW (25,600 Btu/h)Maximum kW (80,000 Btu/h)To Central Heating Modulated Control\Auto Range RatedMinimum kW (25,600 Btu/h)Maximum kW (80,000 Btu/h)THESE INSTRUCTIONS APPLY IN THE UK ONLYTHESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE GAS METERThis appliance must be installed by a competent person in accordancewith the Gas Safety (Installation and Use) Regulations Gas Safety (Installation and Use) Regulations, October 1994all gas appliances must be installed by a competent person inaccordance with the above regulations.

2 Failure to installappliances correctly could lead to The manufacturers notes must not be taken, in any way, asoverriding statutory The compliance with a British Standard does not, of itself,confer immunity from legal obligations. In particular theinstallation of this appliance must be in accordance with therelevant requirements of the following;Gas Safety (Installation and Use) Regulations 1994 as IEE Wiring Regulations BS Building Standards (Scotland)(Consolidation).Bylaws of the local Water Company . Health and Safety Document No. 635 (Electricity at WorkRegulations).

3 The British Gas Material and Installation Specification for centralheating and hot waterIt should be in accordance with the relevant recommendations ofthe following British :1987 Specification for installation of gas fired hot waterboilers of rated input not exceeding 60 :1990 Central Heating for Domestic :1990 Installation of gas hot water supplies for :1:1990 Flues and Ventilation for gas appliances of ratedinput not exceeding 60 kW: :2:1989 Flues and Ventilation for gas appliances of ratedinput not exceeding 60kW: Air :1988 Installation of low pressure gas pipeworkinstallations up to 28mm (R1).

4 BS7593:1993 Central Heating system cleansing and :PART 1 Domestic Butane and Propane gas burninginstallations in permanent To ensure that the installation will perform to the higheststandards, the system and components should conform to anyother relevant British Standards in addition to those mentionedin the The appliance complies with the Essential Requirements ofthe Gas Appliance Directive and other Directives This appliance contains no asbestos is no potential hazard due to the appliance beingelectrically are no substances used that are a potential hazard inrelation to the COSHH Regulations The advice and instructions given in this document covers, asfar as possible, the foreseeable situations which may arise.

5 ContactWorcester Heat Systems Technical Helpline for advice on This appliance is not suitable for external The appliance controls are set to provide a maximum outputof kW for the domestic hot water and central heating The control circuit provides direct burner ignition. A pilot isnot PRINCIPAL APPLIANCE Fig. low thermal capacity Gas to Water heat exchangerincorporating an integral Hot Water heat exchanger to providedomestic hot modulating controls in the central heating and domestichot water modes of expansion vessel, pressure gauge and pressure relief fixed by-pass for the central heating Temperature safety cut-out water flow standard telescopic horizontal flue assembly giving fluelengths from 127mm to extra extension flue kits to provide for flue lengths up optional vertical flue kit to provide for flue lengths up to3000mm including vertical flue facia mounted mechanical General Information1.

6 Installation Regulations21. Installation Requirements .. Page 210. Electrical .. Page 92. General Information .. Page 211. Installing the Appliance .. Page 113. Data Tables .. Page 412. Commissioning the Appliance.. Page 164. Siting the Appliance .. Page 513. Instructions to the User .. Page 185. Siting the Flue.. Page 614. Inspection and Service .. Page 186. Air Supply .. Page 615. Replacement of Parts .. Page 207. Sealed System .. Page 716. Conversion Instructions .. Page 238. Open Vent System .. Page 717. Operational Flow Diagrams.. Page 249. Hot Water Supply .. Page 818. Fault Finding.

7 Page 26.. 19. Component Parts List.. Page 34 ContentsFig. 1. Water flow to waterheatexchangerAutomaticair ventDomesticwater flowswitchPressurerelief valveSafetydischargeDomestichot ELECTRICAL SUPPLYM ains supply: 230V ~, 50 Hz, 180 fuse: 3A., Internal fuses: 2AT HRC(F1), and 1 AF (F2). GAS SUPPLYThe Boiler requires m3/h ( ft3/hr) of natural gas with acalorific value of MJ/m3(1014 Btu/ft3) or m3/h ( ) of propane with a calorific value of MJ/m3(2568 Btu/ft3). The meter governor should deliver a dynamic pressureof 20 mbar (8in ) at the appliance, equivalent to a pressure ofabout mbar at the gas valve on natural gas or mbar( ) at the appliance for gas meter and supply pipes must be capable of supplyingthis quantity of gas in addition to the demand from any otherappliances being served.

8 The table below gives an indication oflimiting gas pipe lengths and the allowance to be made forfittings. Refer to BS6891 for further complete installation, including the gas meter, must betested for soundness and purged. Refer to BS : Each fitting used in the gas line from the meter isequivalent to a length of straight pipe which must be added tothe straight pipe length to give the total : Bend = metres, Tee = metres, 90 Bend = PACKINGThe appliance and flue components are packaged GENERAL INSTALLATIONThe appliance is for connection to a sealed system specified ventilation openings made into a wall orcompartment door must not be the appliance is to be fitted into a compartment then thecompartment must conform to the requirements of BS 6798:1987.

9 Section not place anything on top of the clearances specified for servicing must be FLUEThe appliance has a multi-directional fanned flue standard telescopic flue assembly length is from 127mm flue lengths available are from 350mm to optional vertical flue kit to provide for flue lengths up to3000mm including vertical flue terminal guard, Type K2, GC 393 553, is available from TowerFlue Components, Vale Rise, Tonbridge, TN9 not allow the flue terminal fitted to the outside wall tobecome obstructed or kit for internal fixing of the flue is available CONTROLSThe electronic control system and gas valve modulate the heatinput in response to the domestic hot water temperature andcentral heating setting between minimum and Central Heating Temperature control knob provides for theselection of domestic hot water only (Turned fully anti-clockwise)or central heating and domestic hot water (Turned clockwise).

10 A facia mounted programmer is available as an optional extra. Aremote mounted programmer may be connected to is provision for the connection of a mains voltage roomthermostat and/or a frost electronic controls prevent rapid cycling of the appliance inthe central heating SYSTEM NOTESIMPORTANTC heck that no dirt is left in either the gas or water pipework asthis could cause damage to the appliance. The heating systemshould be flushed and treated in accordance with therecommendations of BS 7593:1992. Thoroughly flush cold watermains supply and purge the gas supply before finally connectingthe water pipe connections throughout a sealed system must becapable of sustaining a pressure of up to 3 valves must conform to the requirements of BS2767 relief valve discharge must be directed away from anyelectrical components or where it would cause a hazard to drain cock to BS 2879 must be fitted to the lowest point of circuit design purposes it is important that due note is takenof the information given in Table 3, section 3 relating to theavailable pump SHOWERS.