Transcription of Branemark External Hex Par - Implant Direct
1 Part 1. Branemark External Hex Branemark Branemark NobelSpeedy Groovy Branemark MK III & MK IV and compatible implants listed below The Branemark Implant was developed in the early 1950's by Professor Par-Ingvar Branemark . Professor Branemark was the first to discover the osseointegration aspect of titanium during his research of bone healing in animals. Currently, Branemark implants, sold by Nobel Biocare of Zurich, Switzerland, are available in three separate platforms : Original Branemark , Branemark MK III & MK IV and NobelSpeedy Groovy Implants: Part 1: External Hex Connection n Branemark diameter - Narrow Platform (NP) n Branemark & diameter - Regular Platform (RP) Branemark n Branemark & diameter - Wide Platform (WP) *New implants have been added to the Nobel Biocare / Branemark line.
2 The new External hex implants are available in the same 3 platforms (NP, RP & WP) as the original Branemark and are restoratively compatible. When ordering components always specify whether Implant has External hex or internal connection as the new Implant names from Nobel Biocare have sim- ilar names for both connections. Many other Implant companies make implants that are restoratively compatible with the Branemark Regular Platform External hex Implant . These companies include: OIC, 3i, Implamed, Zimmer, Interpore, Innova and Steri-Oss. These implants can use the same restorative compo- nents, as the Implant platform, hex and internal threads are identical.
3 The most widely used concept for bridge or single tooth replacement is the UCLA system. It is 3i Osseotite economical and has the widest range of application possibilities. For overdenture applications, the ORS (O-Ring System), the DDB ( Direct Dalla Bona), the adjustable gold rider with bar, and the Hader or Hader-EDS system are most frequently used. Components made by Attachments International are available for: Implants (*see paragraph above) Restoratively Compatible To n Branemark NP External hex - Platform Implamed NP. n Branemark RP & External hex - Platform 3i Minimplant & Standard Osseotite Branemark Mk lll Groovy Implamed RP.
4 NobelSpeedy Groovy IMZ Hex Head & Branemark Mk lll Innova Entegra & Steri-Oss Hex-Loc Branemark Mk lV Steri-Oss Hex-Loc & Swede-Vent Restore RD & Sustain RD. Taper-Lock n Branemark WP & External hex - Platform Implamed WP. Platform Platform Platform Thread Thread Thread 2mm IMZ Hex Head Hex Hex Hex Hex Hex Hex Height Height Height .7mm .7mm Branemark NP Branemark RP Branemark WP. Implant Diameter Implant Diameter / Implant Diameter / Taper-Lock Branemark , NobelReplace, NobelSpeedy are federally registered trademarks of Nobel Biocare, Zurich, Switerland Copyright 2007 Attachments International, Inc., San Mateo, CA. 201. All product names referenced herein are trademarks of their respective companies.
5 Terminology of Components Page Header Sample Guide Branemark Direct Implant Analog Components listed on page Nobel Biocare Compatible Components To The Implant UCLA Abutments Compatible Implant Name Restoration Connection Restorative Components: For ease in selecting components, the Branemark Section is divided by Restoration Connection: Direct To The Implant or . Indirect To An Intermediate Component (Tissue Extensions/Abutments). Overdenture Attachments, Bar Systems, Indirect Individual Parts and Tools are found following in the Indirect Section. Direct The Direct Restorative Components are the elements used to fabricate a restoration that To The Implant will be connected directly to the Implant (s).
6 Indirect The Indirect / Intermediate Restorative Components fit to an intermediate tissue extension Components (abutment) which in turn is connected to the Implant (s). Implant Body: The Implant body is surgically placed into the bone. One surgical method tradi- tionally involved a two-stage surgery, leaving the Implant unloaded in the bone to allow for osseointegration, followed by tissue surgery to uncover the Implant before the restorative components are added. Another method, called Immediate Loading, is a one-stage surgery where the abutment and restoration are attached to the Implant at the time of Implant placement. Intermediate Connector / Tissue Extension: The TE (Tissue Extension) also referred to as an abutment, is the intermediate connector between the Implant and the restoration, it may extend above the tissue.
7 In some instances, a TE extension is subgingival, to provide a more esthetic restoration. Abutment Systems for Branemark Part 1 include: UMA, Multi-Use, Standard Abutment (SA) and HexCone (Estheticone). Abutment Systems for Select Part 2 include: PME. Abutment Systems for Steri-Oss Part 3 include: For Original Steri-Oss Non-Hex Implant : UMA. For Steri-Oss Hex-Loc SD Implant : none For Steri-Oss Replace External Hex Implant : none Implant Standardization: The UMA tissue extension was developed to standardize the components and instruments for many different Implant allowing for an economical inventory and for simplicity of restorative procedures.
8 Its tapered/hexagon fitting surface is iden- tical, regardless of the size or type of Implant employed, while its screw-in base is Implant specific. UMA. Implant Compatibility: Refer to the introduction page of Branemark , Select or Steri-Oss for Implant compatibility information. Branemark , NobelReplace, NobelSpeedy and Steri-Oss are federally registered trademarks of Nobel Biocare, Zurich, Switerland. Copyright 2007 Attachments International, Inc., San Mateo, CA. All product names referenced herein are trademarks of their respective companies. 202. Branemark . Branemark Direct To The Implant Healing Caps Impression Copings Nobel Biocare Compatible Components Implant HEALING CAPS.
9 A titanium healing cap is available requiring the .050" hex healing phase. For customize healing caps, use the driver for insertion. The cap fits directly to the Implant and is Temporary Abutments. used to maintain access through the tissue during the tissue Part 1: External Hex Connection RP WP NP Implant Diameter = Platform NP RP Implant Diameter & = Platform RP NP RP WP. WP Implant Diameter & = Platform WP Description Dimensions Order # Order # Order #. Implant Healing Caps Implant Healing Cap, .050" hex H= = N/A 44-002110 N/A. Implant Healing Cap, .050" hex H= = N/A 44-002120 44-502120-WP. Implant Healing Cap, .050" hex H= = N/A 44-002140 44-502140-WP.
10 Implant Healing Cap, .050" hex H= = N/A 44-002160 44-502160-WP. TOOLS..050" Hex Driver N/A 11-000007 11-000007. IMPRESSION COPINGS To Fit Implant Impression copings are used to take an impression of the stainless steel. The UCLA Hex type impression copings Implant body or the tissue extension, such as the UMA or transfer the hex orientation, the non-hex (bridge) type trans- standard abutment. The Impression copings which fit the fers the Implant position and thread timing only. Implant bodies are made of titanium-others are made of Non Hex Hex Hex Hex NP Implant Diameter = Platform NP RP Implant Diameter & = Platform RP WP Implant Diameter & = Platform WP NP RP WP.