UK T 020 7241 8787 | F 020 7241 8700 | | T +44 20 7241 8740 | F +44 20 7241 8700 | Click here for more information: | BS 5467 Copper SWA PVC BASEC CableAPPLICATIONM ulti- core PVC cable with steel wire armour (SWA). Power and auxiliary fixed wiring cables for use in power networks, underground, outdoor and indoor applications and for use in cable Rating Uo/U Rating Fixed: -25 C to +90 CMinimum Bending Radius to 16mm2 - Fixed: 6 x overall diameter 25mm2 and above - Fixed: 8 x overall diameterCONSTRUCTIONC onductor Class 2 stranded Copper conductorInsulation XLPE (Cross-Linked Polyethylene)Bedding PVC (Polyvinyl Chloride)Armour SWA (Steel Wire Armour)Sheath PVC (Polyvinyl Chloride) core Identification 2 core : Brown Blue 3 core : Brown Black Grey 3 core (optional) : Green/Yellow Blue Brown4 core : Brown Black Blue Grey 4 core (optional) : Green/Yellow Brown Black Grey5 core : Green/Yellow Brown Blue Black Grey 7 core and above.

NOMINAL CROSS SECTIONAL AREA mm2 NOMINAL THICKNESS OF INSULATION mm NOMINAL DIAMETER mm NOMINAL WEIGHT kg/km BW / CW GLAND WRAPAROUND CLEATS ... 240 37 37 34 30 34 30 0.0754 300 61 61 34 30 34 30 0.0601 400 61 61 53 53 53 53 0.047 The above table is in accordance with EN 60228 4 of 6 ...

Tags:

  Multi, Core, Copper, Conductor, Nominal, 4576, 30 0, Bs 5467 copper conductor multi core swa

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of BS 5467 Copper Conductor Multi Core SWA PVC BASEC …

1 UK T 020 7241 8787 | F 020 7241 8700 | | T +44 20 7241 8740 | F +44 20 7241 8700 | Click here for more information: | BS 5467 Copper SWA PVC BASEC CableAPPLICATIONM ulti- core PVC cable with steel wire armour (SWA). Power and auxiliary fixed wiring cables for use in power networks, underground, outdoor and indoor applications and for use in cable Rating Uo/U Rating Fixed: -25 C to +90 CMinimum Bending Radius to 16mm2 - Fixed: 6 x overall diameter 25mm2 and above - Fixed: 8 x overall diameterCONSTRUCTIONC onductor Class 2 stranded Copper conductorInsulation XLPE (Cross-Linked Polyethylene)Bedding PVC (Polyvinyl Chloride)Armour SWA (Steel Wire Armour)Sheath PVC (Polyvinyl Chloride) core Identification 2 core : Brown Blue 3 core : Brown Black Grey 3 core (optional) : Green/Yellow Blue Brown4 core : Brown Black Blue Grey 4 core (optional) : Green/Yellow Brown Black Grey5 core : Green/Yellow Brown Blue Black Grey 7 core and above.

2 White cores with Black numbersSheath Colour Black CABLE THIRD-PARTY ACCREDITATIONSSTANDARDSBS 5467, IEC/EN 60502-1, IEC/EN 60228 Flame Retardant according to IEC/EN 60332-1-2 Eland Product Group:BS 5467 Copper Conductor Multi CoreSWA PVC BASEC CableA9 Stechnicalspecification | 1 of 6 Cables are tested and accredited by BASEC , The British Approvals Service for CablesISO/IEC 17025 LABORATORY TESTED This product is subject to the Quality Assurance protocols of The Cable Lab , an ISO/IEC 17025 accredited cable testing laboratory. Testing includes vertical flame, Conductor resistance, tensile & elongation, and dimensional consistency, verified to published standards and approved product Testing Laboratory8578 REGULATORY COMPLIANCEThis cable is compliant with European Regulation EN 50575, the Construction Products cable meets the requirements of the Low Voltage Directive 2014/35/EU and the RoHS Directive 2011/65/EU.

3 RoHS compliance has been tested and confirmed by The Cable Lab as meeting the requirements of the BSI RoHS Trusted TrustedKITEMARK KM 634267UK T 020 7241 8787 | F 020 7241 8700 | | T +44 20 7241 8740 | F +44 20 7241 8700 | PART OFCORESNOMINAL CROSSSECTIONAL AREAmm2 nominal THICKNESS OF INSULATIONmmNOMINAL DIAMETERmmNOMINALWEIGHTkg/kmBW / CWGLANDWRAPAROUNDCLE ATSU nder ArmourOverallA9S WA .. 515 . 949920CC7A9 SWA 31864820CC8A9 SWA .. 9 . C .13 3 .1330032C C14A9S WA 212 0212 7. 93 6 . 812.. 216 ..119.. 025C C WA312 0312 . 0 6 0 075S-A9S WA4 .. 318 .776420CC8A 9 S WA . 9 S WA .1216 032C C of 6 | technicalspecification Click here for more information: | BS 5467 Copper SWA PVC BASEC CableUK T 020 7241 8787 | F 020 7241 8700 | | T +44 20 7241 8740 | F +44 20 7241 8700 | PART OFCORESNOMINAL CROSSSECTIONAL AREAmm2 NOMINALTHICKNESS OF INSULATIONmmNOMINAL DIAMETERmmNOMINAL WEIGHTkg/kmBW / CWGLANDWRAPAROUND CLE ATSU nder ArmourOverallA 9 S WA 412 0412 0 651.

4 4878050-A 9 S WA 418 .. 716 . 871020CC7A9 SWA50605 . 52087625CC8A 9 S WA 525CC10A 9 S WA C 7. 250 SCC16A9S ..619 .188120CC8A 9 S . 9 S WA12 0 . 9 S . 9 S WA19 025C C 11A9S WA 032C C C14A9S C14technicalspecification | 3 of 6 Clic k here for more information: | BS 5467 Copper SWA PVC BASEC CableA9 SWA5 5 . T 020 7241 8787 | F 020 7241 8700 | | T +44 20 7241 8740 | F +44 20 7241 8700 | 2 Stranded Conductors for Single core and Multi - core CablesNOMINAL CROSS SECTIONAL AREAmm2 MINIMUM NO. OF WIRES IN CONDUCTORMAXIMUM RESISTANCE OF Conductor AT 20 Cohms/kmCircularCircular CompactedShapedAnnealed Copper ConductorCuAlCuAlCuAlPlain .19312 03737181518150 .15 31503737181518150 . above table is in accordance with EN 602284 of 6 | technicalspecification Click here for more information: | BS 5467 Copper SWA PVC BASEC CableUK T 020 7241 8787 | F 020 7241 8700 | | T +44 20 7241 8740 | F +44 20 7241 8700 | Click here for more information.

5 | BS 5467 Copper SWA PVC BASEC CableELECTRICAL CHARACTERISTICS XLPE/PVC/SWA/PVCC urrent Carrying CapacityNOMINAL CROSSSECTIONAL AREAmm2 REFERENCE METHOD C(CLIPPED DIRECT)AmpsREFERENCE METHOD E(IN FREE AIR OR ON A PERFORATED CABLE TRAY, HORIZONTAL OR VERTICAL)AmpsREFERENCE METHOD D(DIRECT IN GROUND OR IN DUCTING INGROUND, IN OR AROUND BUILDINGS)Amps1 Two core CableSingle-Phase AC or DC1 Three or 1 Four core CableThree-PhaseAC1 Two core CableSingle-PhaseAC or DC1 Three or 1 Four core CableThree-PhaseAC1 Two core CableSingle-PhaseAC or DC1 Three or1 Four core 6124152131116963518015418816213911550219 1872281971641357027923829125120316795338 28935430423919712 03923354103532712231504 513864724063062511855154 4153946334328124060752063654639532430069 8599732628446365400787673847728-570 Air ambient temperature: 30 C Ground ambient temperature: 20 C Conductor operating temperature: 90 CNotes1.

6 Where a Conductor operates at a temperature exceeding 70 C it must be ascertained that the equipment connected to the Conductor is suitable for the Conductor operating temperature (see Regulation of the 17th Edition of IEE Wiring Regulations).2. Where cables in this table are connected to equipment or accessories designed to operate at a temperature not exceeding 70 C, the current ratings given in the equivalent table for 70 C thermoplastic insulated cables (Table 4D4A) must be used (see also Regulation of the 17th Edition of IEE Wiring Regulations).The above table is in accordance with Table 4E4A of the 18th Edition of IEE Wiring Regulations BS7671 and IEC 60364-5-52technicalspecification | 5 of 6UK T 020 7241 8787 | F 020 7241 8700 | | T +44 20 7241 8740 | F +44 20 7241 8700 | DROPNOMINAL CROSSSECTIONAL AREAmm2 TWO core CABLE DCTWO core CABLE SINGLE-PHASE ACmV/A/mTHREE OR FOUR core CABLE THREE-PHASE ACmV/ 97.

7 16 . 00 ..15 .13 .15 .13 .13 ..1750 ..1550 ..12 00 .18 54000 .120 ..19 00 .1150 .12 00 .16 5 Conductor operating temperature: 90 Cr = Resistive Component x = Reactive Component z = Impedance ValueThe above table is in accordance with Table 4E4B of the 18th Edition of IEE Wiring Regulations BS7671 and IEC 60364-5-52 For cables havi ng conductors of 16mm2 or less cross sectional area their inductances can be ignored and (mV/A/m)r values only are tabulated. For cables having conductors greater than 16mm2, cross sectional area the impedance values are given as (mV/A/m)z, together with the resistive component (mV/A/m)r and the reactive component (mV/A/m) above paragraph is extracted from Appendix 4 of the 18th Edition of IEE Wiring Regulations BS7671 The information contained within this datasheet is for guidance only and is subject to change without notice or liability.

8 All the information is provided in good faith and is believed to be correct at the time of publication. When selecting cable accessories, please note that actual cable dimensions may vary due to manufacturing of 6 | technicalspecification Click here for more information: | BS 5467 Copper SWA PVC BASEC Cabl


Related search queries