Example: air traffic controller

BS 6724 Copper Conductor Multi Core SWA LSZH BASEC …

Click here for more information: | BS 6724 Copper SWA LSZH BASEC Cable BS 6724 Copper Conductor Multi Core SWA LSZH BASEC Cable Eland Product Group: A9L. APPLICATION CABLE THIRD-PARTY ACCREDITATIONS. Multi -core LSZH cable with steel wire armour (SWA). Power and auxiliary fixed wiring cables for use in power networks, underground, outdoor and indoor applications and for use in Cables are tested and accredited by BASEC , cable ducting. For installation where fire, smoke emission and The British Approvals Service for Cables toxic fumes create a potential threat to life and equipment. CHARACTERISTICS STANDARDS.

BS EN 50267-2-1, BS EN/IEC 60502-1, BS EN/IEC 61034-2 Flame Retardant according to BS EN/IEC 60332-1-2, BS EN/ ... tensile & elongation, and dimensional consistency, verified to published standards and approved product drawings. ISO/IEC 17025 Accredited TestingClass Laboratory ... confirmed by The Cable Lab® as meeting the requirements of the ...

Tags:

  Requirements, Dimensional, Bs en

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of BS 6724 Copper Conductor Multi Core SWA LSZH BASEC …

1 Click here for more information: | BS 6724 Copper SWA LSZH BASEC Cable BS 6724 Copper Conductor Multi Core SWA LSZH BASEC Cable Eland Product Group: A9L. APPLICATION CABLE THIRD-PARTY ACCREDITATIONS. Multi -core LSZH cable with steel wire armour (SWA). Power and auxiliary fixed wiring cables for use in power networks, underground, outdoor and indoor applications and for use in Cables are tested and accredited by BASEC , cable ducting. For installation where fire, smoke emission and The British Approvals Service for Cables toxic fumes create a potential threat to life and equipment. CHARACTERISTICS STANDARDS.

2 Voltage Rating Uo/U BS 6724, bs en /IEC 60228, bs en /IEC 60754-1/2, bs en 50267-2-1, bs en /IEC 60502-1, bs en /IEC 61034-2. Temperature Rating Flame Retardant according to bs en /IEC 60332-1-2, bs en /. IEC 60332-3-24 Cat C. Fixed intallation: -20 C to +90 C. Minimum Bending Radius ISO/IEC 17025 LABORATORY TESTED. to 16mm2 - Fixed: 6 x overall diameter 25mm2 and above - Fixed: 8 x overall diameter This product is subject to the Quality Assurance protocols of The Cable Lab , an ISO/IEC 17025 accredited cable testing laboratory. Testing includes vertical flame, Conductor resistance, tensile & elongation, and dimensional consistency, verified to published standards and approved product drawings.

3 CONSTRUCTION. ISO/IEC. 17025. Conductor Accredited Testing Class 2 stranded Copper Conductor Laboratory 8578. Insulation XLPE (Cross-Linked Polyethylene). REGULATORY COMPLIANCE. Bedding This cable is compliant with European Regulation EN 50575, the Construction LSZH (Low Smoke Zero Halogen) Products Regulation. Armour SWA (Steel Wire Armour). Sheath This cable meets the requirements of the Low Voltage Directive 2014/35/EU. LSZH (Low Smoke Zero Halogen). and the RoHS Directive 2011/65/EU. RoHS compliance has been tested and confirmed by The Cable Lab as meeting the requirements of the BSI RoHS.

4 Core Identification Trusted KitemarkTM. 2 core: Brown Blue 3 core: Brown Black Grey RoHS Trusted 3 core (optional) : Green/Yellow Blue Brown KITEMARK . 4 core: Brown Black Blue Grey KM 634267. 4 core (optional) : Green/Yellow Brown Black Grey 5 core: Green/Yellow Brown Blue Black Grey 7 core and above: White cores with Black numbers Sheath Colour Black UK T 020 7241 8787 | F 020 7241 8700 | | International T +44 20 7241 8740 | F +44 20 7241 8700 | technicalspecification | 1 of 5. Click here for more information: | BS 6724 Copper SWA LSZH BASEC Cable DIMENSIONS. ELAND PART NO. NO. OF NOMINAL CROSS NOMINAL NOMINAL DIAMETER NOMINAL BW / CW WRAPAROUND.

5 CORES SECTIONAL AREA THICKNESS mm WEIGHT GLAND CLEATS. mm2 OF INSULATION kg/km mm Under Armour Overall A9 SWA2015 LSZH 2 302 20S CC5. A9 SWA2025 LSZH 2 346 20S CC6. A9 SWA2040 LSZH 2 4 410 20S CC6. A9 SWA2060 LSZH 2 6 499 20 CC7. A9 SWA210 LSZH 2 10 18 648 20 CC8. A9 SWA216 LSZH 2 16 978 20 CC9. A9 SWA225 LSZH 2 25 1290 25 CC9. A9 SWA235 LSZH 2 35 1500 32 CC10. A9 SWA250 LSZH 2 50 1 19 1890 32 CC12. A9 SWA270 LSZH 2 70 22 29 2450 32 CC12. A9 SWA295 LSZH 2 95 3300 32 CC14. A9 SWA2120 LSZH 2 120 4020 40 CC16. A9 SWA2150 LSZH 2 150 4750 40 CC18. A9 SWA3015 LSZH 3 330 20S CC5. A9 SWA3025 LSZH 3 390 20S CC6.

6 A9 SWA3040 LSZH 3 4 10 464 20S CC7. A9 SWA3060 LSZH 3 6 568 20 CC7. A9 SWA310 LSZH 3 10 866 20 CC8. A9 SWA316 LSZH 3 16 1152 25 CC9. A9 SWA325 LSZH 3 25 1800 25 CC11. A9 SWA335 LSZH 3 35 2230 32 CC12. A9 SWA350 LSZH 3 50 1 2490 32 CC12. A9 SWA370 LSZH 3 70 3290 32 CC14. A9 SWA395 LSZH 3 95 37 4440 40 CC16. A9 SWA3120 LSZH 3 120 32 5470 40 CC16. A9 SWA3150 LSZH 3 150 6930 50S CC18. A9 SWA4015 LSZH 4 365 20S CC6. A9 SWA4025 LSZH 4 15 438 20S CC6. A9 SWA4040 LSZH 4 4 11 532 20 CC7. A9 SWA4060 LSZH 4 6 764 20 CC8. A9 SWA410 LSZH 4 10 1013 25 CC9. A9 SWA416 LSZH 4 16 17 1360 25 CC10. A9 SWA425 LSZH 4 25 21 2160 32 CC11.

7 A9 SWA435 LSZH 4 35 2690 32 CC12. A9 SWA450 LSZH 4 50 1 25 32 3130 32 CC14. A9 SWA470 LSZH 4 70 4500 40 CC16. A9 SWA495 LSZH 4 95 5600 50S CC18. A9 SWA4120 LSZH 4 120 7400 50 CC20. A9 SWA4150 LSZH 4 150 8780 50 - A9 SWA4185 LSZH 4 185 10630 63S - A9 SWA4240 LSZH 4 240 63 13390 63 - A9 SWA4300 LSZH 4 300 14998 75S - A9 SWA5015 LSZH 5 410 20S CC6. A9 SWA5025 LSZH 5 470 20S CC7. A9 SWA5040 LSZH 5 4 13 710 20 CC7. A9 SWA5060 LSZH 5 6 20 876 25 CC8. UK T 020 7241 8787 | F 020 7241 8700 | | 2 of 5 | technicalspecification International T +44 20 7241 8740 | F +44 20 7241 8700 | Click here for more information: | BS 6724 Copper SWA LSZH BASEC Cable ELAND PART NO.

8 NO. OF NOMINAL CROSS NOMINAL NOMINAL DIAMETER NOMINAL BW / CW WRAPAROUND. CORES SECTIONAL AREA THICKNESS mm WEIGHT GLAND CLEATS. mm2 OF INSULATION kg/km mm Under Armour Overall A9 SWA510 LSZH 5 10 1165 25 CC10. A9 SWA516 LSZH 5 16 20 1742 32 CC11. A9 SWA525 LSZH 5 25 2323 32 CC14. A9 SWA535 LSZH 5 35 2932 40 CC14. A9 SWA550 LSZH 5 50 1 4192 50S CC16. A9 SWA570 LSZH 5 70 5500 50S CC18. A9 SWA595 LSZH 5 95 7145 50S CC20. A9 SWA7015 LSZH 7 470 20S CC6. A9 SWA7025 LSZH 7 600 20 CC7. A9 SWA1215 LSZH 12 780 20 CC8. A9 SWA1225 LSZH 12 1000 25 CC9. A9 SWA1915 LSZH 19 1000 25 CC9. A9 SWA1925 LSZH 19 1540 25 CC11.

9 A9 SWA2715 LSZH 27 20 1500 32 CC11. A9 SWA2725 LSZH 27 24 1950 32 CC14. A9 SWA3715 LSZH 37 29 1800 32 CC12. A9 SWA3725 LSZH 37 2350 40 CC14. CONDUCTORS. Class 2 Stranded Conductors for Single Core and Multi -Core Cables NOMINAL CROSS MINIMUM NO. OF WIRES IN Conductor MAXIMUM RESISTANCE OF Conductor AT 20 C. SECTIONAL AREA ohms/km mm2. Circular Circular Compacted Shaped Annealed Copper Conductor Cu Al Cu Al Cu Al Plain Wires 7 - 6 - - - 7 - 6 - - - 4 7 - 6 - - - 6 7 - 6 - - - 10 7 7 6 6 - - 16 7 7 6 6 - - 25 7 7 6 6 6 6 35 7 7 6 6 6 6 50 19 19 6 6 6 6 70 19 19 12 12 12 12 95 19 19 15 15 15 15 120 37 37 18 15 18 15 150 37 37 18 15 18 15 185 37 37 30 30 30 30 240 37 37 34 30 34 30 The above table is in accordance with bs en 60228 (previously BS 6360).

10 UK T 020 7241 8787 | F 020 7241 8700 | | International T +44 20 7241 8740 | F +44 20 7241 8700 | technicalspecification | 3 of 5. Click here for more information: | BS 6724 Coppe SWA LSZH BASEC Cable ELECTRICAL CHARACTERISTICS XLPE/LSZH/SWA/LSZH. Current Carrying Capacity NOMINAL CROSS REFERENCE METHOD C REFERENCE METHOD E REFERENCE METHOD D. SECTIONAL AREA (CLIPPED DIRECT) (IN FREE AIR OR ON A PERFORATED CABLE TRAY, (DIRECT IN GROUND OR IN DUCTING, IN GROUND, mm2 Amps HORIZONTAL OR VERTICAL) IN OR AROUND BUILDINGS). Amps Amps 1 Two Core Cable 1 Three or 1 Two Core Cable 1 Three or 1 Two Core Cable 1 Three or Single-Phase 1 Four Core Cable Single-Phase 1 Four Core Cable Single-Phase 1 Four Core Cable AC or DC Three-Phase AC or DC Three-Phase AC or DC Three-Phase AC AC AC.