Example: tourism industry

BS88 Cross reference poster - Cooper Bussmann

Bussmann series bs88 fuse links Cross referenceIMPORTANT NOTICE: The comparative catalogue numbers shown on this guide are derived from the latest available published information from the manufacturers shown. Competitors products may differ from Bussmann series products, therefore it is recommended that each application is checked for electrical and mechanical characteristics before substitution are made. Eaton s Bussmann business is not responsible for mis-applications of our products. Proper overcurrent protection is applications dependant, consult our latest catalogues and applications literature or contact our local sales engineer or Eaton s Bussmann business application engineering department on +44 (0) 1509 882 your local Eaton offi ceEaton - Bussmann Melton Road, Burton-on-the-WoldsLE12 5TH United KingdomTel: +44 (0)1509 882 600 Email: number: CC132002EN British standard Bussmann series standard catalogue numbers 240 to 550 V Lawson SSNSESMDLSTNITTIATISTCPTISTFPTBTBCTCTFTK F/TMFTKMTMTTMTTTLTTLMTLU MEMSSSN2SP-LSSA2SB3SB4SD5 SOSD6SE3/SE4SF3/SF4SF5SF6SF7SG7SH8SH9SY9 SY10SH10- MersenBNS42V/ BSS55 VBES42V/BES55 VBNIT42V/BNIT55 VBTIA42 VBTIS42 VBTCP42 VBTFP42 VBTBC42 VBTC42 VBTF42 VBTKF42V/BTMF69 VBTKM42 VBTKM42 VBTTM42 VBTLM42V General industrial fuses bs88 size referenceE1F1F2A1A2A3A4B1B2B3/B4C1C2C3D1 IEC utilisation classgGgGgGgGgGgGgGgGgGgGgGgGgGgG

Bussmann series BS88 fuse links cross reference IMPORTANT NOTICE: The comparative catalogue numbers shown on this guide are derived from the latest available published information from the manufacturers shown.

Tags:

  Cross, Reference, Poster, Cross reference, Bs88 cross reference poster, Bs88

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of BS88 Cross reference poster - Cooper Bussmann

1 Bussmann series bs88 fuse links Cross referenceIMPORTANT NOTICE: The comparative catalogue numbers shown on this guide are derived from the latest available published information from the manufacturers shown. Competitors products may differ from Bussmann series products, therefore it is recommended that each application is checked for electrical and mechanical characteristics before substitution are made. Eaton s Bussmann business is not responsible for mis-applications of our products. Proper overcurrent protection is applications dependant, consult our latest catalogues and applications literature or contact our local sales engineer or Eaton s Bussmann business application engineering department on +44 (0) 1509 882 your local Eaton offi ceEaton - Bussmann Melton Road, Burton-on-the-WoldsLE12 5TH United KingdomTel: +44 (0)1509 882 600 Email: number: CC132002EN British standard Bussmann series standard catalogue numbers 240 to 550 V Lawson SSNSESMDLSTNITTIATISTCPTISTFPTBTBCTCTFTK F/TMFTKMTMTTMTTTLTTLMTLU MEMSSSN2SP-LSSA2SB3SB4SD5 SOSD6SE3/SE4SF3/SF4SF5SF6SF7SG7SH8SH9SY9 SY10SH10- MersenBNS42V/ BSS55 VBES42V/BES55 VBNIT42V/BNIT55 VBTIA42 VBTIS42 VBTCP42 VBTFP42 VBTBC42 VBTC42 VBTF42 VBTKF42V/BTMF69 VBTKM42 VBTKM42 VBTTM42 VBTLM42V General industrial fuses bs88 size referenceE1F1F2A1A2A3A4B1B2B3/B4C1C2C3D1 IEC utilisation classgGgGgGgGgGgGgGgGgGgGgGgGgGgGgGgGgGg GgGgGgGgGgG Rated voltage (V )240550550415240550550500500500415500/55 0500/550500415415415415690550550550550 Rated current (Amps)

2 2222222403280125228012525012535545045071 0710710 4444444504010016044101603151604005005008 0080080066666666350200662003552006306301 0001000101010101010106310104002501250125 0161616161616168016163152020202020202010 0 20** 20**25252525252525 25** 25**32323232323232 32** 32**40 40** 40**50 50** 50**63 63** 63** Motor fuses IEC utilisation classgMgMgMgMgMgMgMgMgMgMgMgMgM Rated voltage (V )415415415500500415415415500415415415550 Extended motor range20M2563M8020M2532M4063M80100M125100 M125200M25063M80100M125200M315315M400400 M50020M3263M10020M3232M5063M100100M16010 0M160200M31563M100100M160400M50020M3632M 4032M63100M200100M20032M3632M5032M4032M6 332M5032M63 Dimensions (mm) Overall Fixing centresN/AN/AN/ Maximum Tag configurationSolid BladeSolid BladeSolid BladeFerruleOffsetOffsetOffsetOffsetOffs etOffsetOffsetCentreCentreCentreCentreCe ntreCentreCentreCentreCentreCentreCentre Centre Number of hole fixings00002222222222224444444 Bussmann series Camaster/Safeloc Fuse Holder 32 NNS63 ENSCM32 FCCM32 FCM63 FCM100F Bussmann series Red Spot Fuse HolderSC20SC32SC63RS20 HRS32RS63RS100RS400RS400 Approvals bs88 IEC 60269 ASTA Full load circuit of typical induction motorsMotor ratingRated voltage (V ) Direct on-line startingMotorratingAmpsRecommendedfuse linkAlternative extendedmotor circuit Assisted start (Star/Delta, Auto-Transformer)

3 Motor FLCAmpsRecommendedfuse linkAlternative extendedmotor circuit products shown on this Cross reference chart are a selection of some of the most commonlyused low voltage fuse manufactures one of the most comprehensive range of low voltage fuse links. If you cannot find the fuse link you need please contact Eaton s technical application support for s Bussmann series technical assistance contact numbers:Tel: +44 (0) 1509 882 699 Fax: +44 (0) 1509 882 794 Email: Rated voltage 500 V * For information on our Red Spot fuse range, rated 660/690 V please contact our Technical Department + 44 (0) 1509 882 699or, NOTICE: The comparative catalogue numbers shown on this guide are derived from the latest available published information from the manufacturers shown. Competitors products may differ from Eaton s Bussmann series products, therefore it is recommended that each application is checked for electrical and mechanical characteristics before substitution are made.

4 Eaton is not responsible for mis-applications of our products. Proper overcurrent protection is applications dependant, consult our latest catalogues and applications literature or contact our local sales engineer or Eaton s application engineering department on +44 (0) 1509 882 699.