Example: tourism industry

Building Management Systems (BMS) - bms …

Building Management Systems (BMS)Our BMS solutionHardwareWe provide a complete HVAC and lighting solution for commercial, institutional and industrial multiple product lines utilizing LonWorks and BACnet communications protocols allows us to maintain an objectiveperspective when designing and implementing solutions for our clients. In addition, this depth of representation allows us toimplement transition plans which bring clients forward out of proprietary Systems into open Systems while protecting theirexisting our Building Management software provides the operator with optimum communication between automation andmanagement SCADA system -level software is developed from considerable experience in the automation sector to bring benefits to allusers, from system integrators to end-users, by minimising investment in familiarisation and training.

Building Management Systems (BMS) Our BMS solution Hardware We provide a complete HVAC and lighting solution for commercial, institutional and industrial buildings.

Tags:

  System, Management, Building, Building management systems

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Building Management Systems (BMS) - bms …

1 Building Management Systems (BMS)Our BMS solutionHardwareWe provide a complete HVAC and lighting solution for commercial, institutional and industrial multiple product lines utilizing LonWorks and BACnet communications protocols allows us to maintain an objectiveperspective when designing and implementing solutions for our clients. In addition, this depth of representation allows us toimplement transition plans which bring clients forward out of proprietary Systems into open Systems while protecting theirexisting our Building Management software provides the operator with optimum communication between automation andmanagement SCADA system -level software is developed from considerable experience in the automation sector to bring benefits to allusers, from system integrators to end-users, by minimising investment in familiarisation and training.

2 It can easily be integratedinto any Windows application and brings to you real-time viewing and control over your Building 's first LON device for optimisation of air distribution in Variable Air Volume (VAV) AHUsystemsUnique chiller plant control solution (CPCS) that guarantees best performance and energy savingFull range of pre-programmed controllers that simplifiy installation, commissioning, reducesimplementation time and ensures proper and energy efficient operationautomatically avoids activating faulty equipment, relying on serviceable equipment to meet calculated cooling for all chiller plants piped in common header pipe configuration, even when of quantity of chillers, cooling towersand water pumps are not equal in number (.)

3 In plants with extra standby pumps and or cooling towers)FEATURES automatically calculates cooling demand from supply/returntemperature and the flow rate of chilled water to decidethe number of chillers to switch on or next available chiller, pump and cooling towerto turn on or off in sequence to maintain equal runninghours and even wear & tear of each piece of bypass valve to maintain differential pressureacross supply and return headers. system also workswith de-coupling Systems without bypass single point failures by having distributedintelligence- each piece of equipment is assigned oneDDC- ensuring reliable chiller plant offer a series of open, pre-programmed controllers for virtually every application:Highlight 1.

4 Pre-programmed ControllersSimplifies installation, commissioning and future expansion, dramatically reduces implementation timeensures proper operation, effectively reduces engineering and maintenance cost, saves time and money for SystemIntegrators, provides reliability and peace of mind to Building owners and ensures energy efficient control strategiesFan Coil UnitVariable Air Volume (VAV) Terminal BoxesAir Handling UnitsChillers, Boilers & PumpsVentilation FansLighting Direct Digital ControllersGeneral Purpose Direct Digital ControllersMotor Direct Digital ControllersHighlight 2: Universal Chiller Plant Control SolutionAn application specific LonWorks DDC based system for capacity and lead/lag control of a group of chillers and necessaryperipheral equipment.

5 The system is pieced together using specific interactive modules, one for each type of equipmentthat makes up a chiller plant, and together with duty coordinating modules and a capacity commander module, is able tosequence all related equipment for the proper functioning of the BMS solution - Feature HighlightsWith the HVAC and lighting controlsintegrated using our LonWorks devices,the University Campus startedoperations in the last quarter of eight chillers in two chiller plantsgenerating a total capacity 5550 tons,after fine tuning, an energy savings ofapproximately 20% was achieved infirst quarter of 2006 even with theincreasing student addition, using a variable pressureregulator for the Air Handling Unitsoperation, a saving of almost 50% onpower energy was achieved usingvariable static pressure regulator insteadon standart constant pressure diagram shows comparison of AHU duct pressurewhen using constant static pressure control method(purple) and UVP-LD (blue).

6 The initial spike shows how the UVP-LD allowed forhigher static pressure to improve cooling/heatingresponse, allowing the space temperature to reachdesired set-points sooner than a constant static pressuresystem is able to achieve. After that, the duct pressuremaintained was considerably lower than when controlledwith constant pressure method - resulting in huge energysavings without compromising on space temperatureReal installation testing has revealed that saving ofalmost 50% on power energy was achieved using variablestatic pressure regulator instead on standart constantpressure AdvantagesAHU fan runs at lower average speeds resulting in moreenergy savingsIndividual VAV boxes receive 'just enough' cooling airflow resulting in more effective cooling in individual roomsCooling demand is met more quickly and efficientlyRequires no modification of existing hardware

7 Beyondinstallation of the deviceSmall dimensions - easy panel mount energy savings at low installation costOur BMS solution - Feature HighlightsThe world's first Lon devicedesigned to optimise airdistribution in Variable Air Volume(VAV) AHU Systems and has beenproven to greatly reduce energyusage. This is achieved bycontinually adjusting static airpressure set-points of an AHU asopposed to conventional VAV AHUsystems which rely on a fixedstatic air pressure 3: Variable Pressure RegulatorCase study - University CampusBuilding Management Systems is a Green Building Systems provider, offeringrenewable energy solutions and Building automation Systems for governmental,commercial, industrial, residential buildings and Home infrastructure product portfolio and expertise help our customers and communities inimproving their business efficiency, reducing their operating costs, optimizingtheir energy usage, and ultimately increasing their are taking the lead in transforming the way communities and buildings aredesigned, built and operated, towards creating Green Building communities.

8 Maintaining sustainable built-environment, protecting the ecosystem, and reducingthe CO2 emission in our


Related search queries