Example: confidence

Bulletin 194R/140U External Operating Handles Selection Guide

Selection GuideBulletin 194R/140U External Operating HandlesBulletin 194r /140 UExternal Operating Handles 2 Visit our website: 194r -SG004B-EN-PNotesBulletin 194r /140 UExternal Operating Handles3 Visit our website: 194r -SG004B-EN-PProduct Overview/Product SelectionBulletin 194R/140U Next Generation Disconnect Handles Available in matte black for ON-OFF switching and red/yellow forEmergency OFF requirements One-hand operation to open the door Operating handle environmental ratings:- Type 3R, 3, 12, 4, 4X Handle with or without test mode; Trip indication on Bul 140U handle Padlockable handle for up to three padlocks Defeater mechanism NFPA 79 internal Operating handle with shaft (option) Option for either vertical or 45 mount holesTable of ContentsProduct 5 Product SelectionOperating Handles (Accepts 3 Padlocks)DescriptionShaft TypeFor Use WithColorEnvironmental RatingCat.

Case Circuit Breakers, 140M Motor Protection Circuit Brealers & Motor Circuit Protectors; 100, 125, and 250A devices Black Type 3R, 3, 12, 4, 4X 140U-PB Red/Yellow Type 3R, 3, 12, 4, 4X 140U-PY OSHA Lockout/Tag Out Compliance (LOTO) OSHA CFR36 Section 1910 mandates that disconnects be able to be locked out while in the OFF position during ...

Tags:

  Breaker, Circuit, Circuit breakers, 194r

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Bulletin 194R/140U External Operating Handles Selection Guide

1 Selection GuideBulletin 194R/140U External Operating HandlesBulletin 194r /140 UExternal Operating Handles 2 Visit our website: 194r -SG004B-EN-PNotesBulletin 194r /140 UExternal Operating Handles3 Visit our website: 194r -SG004B-EN-PProduct Overview/Product SelectionBulletin 194R/140U Next Generation Disconnect Handles Available in matte black for ON-OFF switching and red/yellow forEmergency OFF requirements One-hand operation to open the door Operating handle environmental ratings:- Type 3R, 3, 12, 4, 4X Handle with or without test mode; Trip indication on Bul 140U handle Padlockable handle for up to three padlocks Defeater mechanism NFPA 79 internal Operating handle with shaft (option) Option for either vertical or 45 mount holesTable of ContentsProduct 5 Product SelectionOperating Handles (Accepts 3 Padlocks)DescriptionShaft TypeFor Use WithColorEnvironmental RatingCat.

2 Handle,standard194R-S, 194r -Noperating shaftsBul. 194r disconnectswitches up to 60 ABlackType 3R, 3, 12, 4, 4X194R-PBRed/Yellow Type 3R, 3, 12, 4, 4X194R-PYPadlockable handle, testmodeBlackType 3R, 3, 12, 4, 4X194R-PBTRed/YellowType 3R, 3, 12, 4, 4X194R-PYTP adlockable handle,standard, with tripindicationBul. 140U/UE MoldedCase circuit Breakers,140M Motor ProtectionCircuit Brealers & MotorCircuit Protectors; 100,125, and 250A devicesBlackType 3R, 3, 12, 4, 4X140U-PBRed/Yellow Type 3R, 3, 12, 4, 4X140U-PYOSHA Lockout/Tag Out Compliance (LOTO)OSHA CFR36 Section 1910 mandates that disconnects be able to be locked out while in the OFF position during servicing. All Bulletin 194R/140U Handles comply with this important safety requirement.(Please see NFPA Article 430 for disconnect requirements of motor applications)Standards ComplianceIEC/EN 60947-3UL 98UL 489UL 508 CSA, Nos.

3 4, 5, 14 VDE 0660 CertificationsCE MarkedcULus Recognized (File Vol 2) Bulletin 194R/140U Next Generation Disconnect Handles have beenredesigned with a unique form and contemporary styling to improveboth comfort and performance in the field. These Handles are designedto be used with Bulletin 194r fused and non-fused disconnectswitches up to 60 A, Bulletin 140U/UE Molded Case circuit Breakers, Bulletin 140M Motor Protection circuit Breakers, and Bulletin 140 MMotor circuit Protectors. Bulletin 194r /140 UExternal Operating Handles 4 Visit our website: 194r -SG004B-EN-PProduct Selection /SpecificationsOperating ShaftsDescriptionFor Use WithOperating ShaftLengthCat. shaft140U-P*, 194r -P*, and 194r -P*T handles12 in. ( cm) 194r -S121 in. ( cm) 194r -S2 NFPA 79 internal operatinghandle with shaft12 in.

4 ( cm) 194r -N121 in. ( cm) 194r -N2 SpecificationsSpecificationsStandards ComplianceIEC/EN 60947-3; UL 98; UL 489; UL 508; CSA, Nos. 4, 5, 14;VDE 0660 CertificationsCE Marked, cULus Recognized (File No. E3125 Vol 2)Environmental RatingsType 3R, 3, 12, 4, 4 XShaft Diameter6 mm (1/4 in.) squareScrewdriver6 mm (1/4 in.) flathead; T-20 Recommended N m (25 lb in.) Bulletin 140 UTo order the components for a handle kit, select the rated current of the protective device and then one of each of the following:rotary operator, handle, and SizeRotaryOperatorHandleOperating Shaft Cat. in. ( cm) 194r -S121 in. ( cm) 194r -S2 Red/Yellow140U-PY12 in. ( cm) 194r -S121 in. ( cm) 194r -S2H140U-H-RMXB lack140U-PB12 in. ( cm) 194r -S121 in. ( cm) 194r -S2 Red/Yellow140U-PY12 in. ( cm) 194r -S121 in. ( cm) 194r -S2J140U-J-RMXB lack140U-PB12 in.

5 ( cm) 194r -S121 in. ( cm) 194r -S2 Red/Yellow140U-PY12 in. ( cm) 194r -S121 in. ( cm) 194r -S2 If NFPA 79 operator is required, replace Cat. No. 194r -S1 with Cat. No. 194r -N1or Cat. No. 194r -S2 with Cat. No. 194r /140 UExternal Operating Handles5 Visit our website: 194r -SG004B-EN-PApproximate DimensionsApproximate DimensionsDimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing HandlesFront of Cover50( )50( )25( )25( )(2) - ( ) 35( )63( ) ( )25( )(2) - ( ) 35( )ORFrontRight Side80(3 .15) ( )114(4 .49)51( ) ( ) ( )34( ) (1) mm( )Allen-Bradley, Rockwell Software, Rockwell Automation, and LISTEN. THINK. SOLVE are trademarks of Rockwell Automation, not belonging to Rockwell Automation are property of their respective 194r -SG004B-EN-P - April 2012 Supercedes Publication 194r -SG004A-EN-P - February 2012 Copyright 2012 Rockwell Automation, Inc.

6 All rights reserved. Printed in the