Example: bankruptcy

Bulletin 500 Line Open Type Modular Kits and Components ...

Bulletin 500 Line Open Type ModularKits and ComponentsSelection GuideBulletin 500, 500F, 509 NEMA AC Contactors and Starters2 Product OverviewNEMA AC Contactor and Starter Modular Kits and ComponentsBulletin500500F509 FeaturesTop-wired contactorFeed-through wired contactorNon-reversing starterNEMA Rating [A] Power (1 Hp) ( Hp) 3-Phase3 Power (1-1 Hp) ( Hp) 3-Phase4 Power (1-1 Hp) 3-Phase5 Power ( Hp) Motor Voltage ( Hp) (1 Hp)Standards NEMA/EEMAC ICS2 (Industrial Controlsand Systems) UL 508 CSA , No.

Certifications CSA Certified (LR1234) UL Listed (File No. E3125, Guide No. NLDX) Catalog Number Explanation For flexibility, devices may be ordered in a convenient modular kit or as individual components. Modular Kit Example Cat. No. 500 – B – O – D – 930 – 17 abcde A modular kit includes: Base contactor Selectable coil voltage

Tags:

  Certifications

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Bulletin 500 Line Open Type Modular Kits and Components ...

1 Bulletin 500 Line Open Type ModularKits and ComponentsSelection GuideBulletin 500, 500F, 509 NEMA AC Contactors and Starters2 Product OverviewNEMA AC Contactor and Starter Modular Kits and ComponentsBulletin500500F509 FeaturesTop-wired contactorFeed-through wired contactorNon-reversing starterNEMA Rating [A] Power (1 Hp) ( Hp) 3-Phase3 Power (1-1 Hp) ( Hp) 3-Phase4 Power (1-1 Hp) 3-Phase5 Power ( Hp) Motor Voltage ( Hp) (1 Hp)Standards NEMA/EEMAC ICS2 (Industrial Controlsand Systems) UL 508 CSA , No.

2 14 ABS 4 USCG 46 CFR IEEE 45 NEMA/EEMAC ICS2 (Industrial Controlsand Systems) UL 508 CSA , No. 14 ABS 4 USCG 46 CFR IEEE 45 NEMA/EEMAC ICS 2(Industrial Controls and Systems) UL 508 CSA , No. 14 ABS 4 USCG 46 CFR UL Listed (File No. E3125; Guide ) (File No. E10314; Guide No. NPKR) CSA Certified (LR1234) CE Marked (Per EN 60947) American Bureau of Shipping (ABS) UL Listed (File No. E3125; Guide ) (File No. E10314; Guide No. NPKR) CSA Certified (LR1234) CE Marked (Per EN 60947) American Bureau of Shipping (ABS) UL Listed (File No.)

3 E3125; Guide ) CSA Certified (File LR 1234) CE Marked (per EN 60947-4-1) American Bureau of Shipping (ABS) Hazardous Location: UL Listed (File ), CSA Certified (File No. LR 11924)Product SelectionPage 3 Page 7 Page 11 NEMA sizes for open-type Bulletin 500 top-wired contractors, Bulletin 500F feed-through contactors, and Bulletin 509 full-voltage starters, are provided as Modular kits for faster delivery. Other sizes and enclosed-type devices are also available. Publication 500-SG008A-EN-PBulletin 500 NEMA AC Contactors3!

4 500-SG008A-EN-PCat. No. Explanation All power connections are at the top of the contactor for wiringconvenience Contactor can be field wired for single- or three-phase applicationsNEMA sizes Available as Components or a Modular kit for faster delivery Product selection can be done via two options: Ordering a complete kit Ordering individual Components Top-wired contactor includes a 120V AC coil, (1) auxiliarycontact, top-wiring kit, and load-side terminal shield, as standardNEMA sizes 00, Available as factory assembledTable of ContentsModular Kits.

5 4 Components .. 5 Factory Assembled .. 15 Full Load Currentsof AC Motors .. 20 Standards ComplianceNEMA/EEMAC ICS 2UL 508 CSA 4 AmericanBureau of ShippingUCSG 46 CFR 45EN/IEC 60947-4-1CE MarkedCertifications CSA Certified (LR1234) UL Listed (File No. E3125,Guide No. NLDX)Catalog Number ExplanationFor flexibility, devices may be ordered in a convenient Modular kit or as individual Kit Example Cat. B O D 930 17abcdeA Modular kit includes: Base contactor Selectable coil voltage Top-wiring kit Selectable number of poles Load-side terminal shield Selectable optionsaNEMA SizeCodeDescriptionA0B1C2D3E4bNEMA Enclosure TypeCodeTypeONo enclosurecNominal Coil VoltageCodeVoltageFrequencyA220V240V50 Hz60 HzB440V480V50 Hz60 HzC550V600V50 Hz60 HzD110V120V50 Hz60 HzF277V60 HzI415V50 HzJ24V50/60 HzN380V50 HzVL24V DC DC dNumber of PolesCodeVoltage Description930 Three Power Poles and (1) AuxiliaryContact940 Four Power Poles and (1)

6 AuxiliaryContact950 Five Power Poles and (1) AuxiliaryContacteOptionsCodeDescription1 7 Surge Suppressor for 120 or 240V ACCoil90(1) Auxiliary Contact 91(1) Auxiliary Contact Bulletin 500 Open Type Top-Wired Contactor Up to (6) combinations of auxiliary contacts canbe selected. Example: Code 90011 indicates (2) and (2) 500 NEMA AC Contactors4! 500-SG008A-EN-P Product Selection - Modular Kit Coil Voltage Code[V]241101201252082202402502773804154 40480550600AC, 50 HzJD A NIB C AC, 60 HzJ D H A F B CDC VL VG VG DC voltage code is only available on NEMA size When ordering a DC voltage code, add "DC" to the catalog number.

7 Example: ContactorIncludes a 120V AC coil and (1) auxiliary contactor as Selection of NEMA sizes by Modular KitsOptions for Modular KitOptionsCodeDescription17 Surge Suppressor for 120 or 240V AC Coil90(1) Auxiliary Contact 91(1) Auxiliary Contact Up to (6) combinations of auxiliary contacts can be selected. Example: Code 90011 indicates (2) and (2) : The base contactor includes a 120V AC coil as standard. For all other voltages, a second coil will be included in the Modular kit forfield swap cat. no.

8 As listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 500-AO 940becomes Cat. No. 500-AOD940. Example: Cat. No. 500-COD930-17-90includes a NEMA size 2, 3-pole, contactor with a 120V AC coil, surge suppressor, and (1) [A]Max. Horsepower RatingFull Load Current Must Not Exceed Continuous Ampere Rating 1-Phase Motor Voltage3-Phase Motor Voltage600V AC Maximum 60 Hz115V230V200V230V50 Power Poles4 Power Poles5 Power 018 1 2335 5500-AO 930500-AO 940500-AO 950127 23 10 10500-BO 930500-BO 940500-BO 950245 3 1015 25 25500-CO 930500-CO 940500-CO 930500-DO 940500-DO 9504135 405075100500-EO 930500-EO 940500-EO 9505270 75100150200 6540 150200300400 7810 300600600 81215 450900900 92250 80016001600 See

9 Page 7 for NEMA sizes 00, 500 NEMA AC Contactors5! 500-SG008A-EN-PProduct Selection - ComponentsBase ContactorCoilAuxiliary ContactContactorSurge SuppressorPower PoleTop Wire KitLoad -Side Terminal ShieldBase ContactorNEMA SizeContinuous Ampere Rating[A]Cat. Contact ContactorsDescriptionNEMA SizeCat. and SuppressorDescriptionNEMA SizeCat. AC Varistor599-KA04 Power Pole AddersDescriptionNEMA SizeCat. Wiring KitNEMA SizeCat. Shield KitNEMA SizeCat. ,4599-TS34 Product Selection of NEMA sizes by ComponentsCoilsDescriptionNEMA 50/60 HzCB013CC013CD013CE013110V 50 Hz,120V 60 HzCB236CC236CD236CE236208V 60 HzCB249CC249CD249CE249220V 50 Hz,240V 60 HzCB254CC254CD254CE254277V 60 HzCB260CC260CD260CE260380V 50 HzCB354CC354CD354CE354415V 50 HzCB357CC357CD357CE357440V 50 Hz,480V 60 HzCB273CC273CD273CE273550V 50 Hz,600V 60 HzCB278CC278CD278CE27824V DC599-B24DC599-C24DC599-D24DC Note:The base contactor includes a 120V AC coil as standard.

10 Forall other voltages, select an alternate component coil for 500 NEMA AC Contactors Coil Voltage Code[V]241101201252082202402502773804154 40480550600AC, 50 HzJD A NIB C AC, 60 HzJ D H A F B CDCVL VG VG Product Selection of NEMA sizes 00, , as Factory AssembledProduct Selection - Factory AssembledThe cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 500-AO 940becomes Cat. No. 500-AOD940. NEMASizeContinuousAmpereRating [A]Max. Horsepower RatingFull Load Current Must Not Exceed Continuous Ampere Rating 1-Phase Motor Voltage3-Phase Motor Voltage600V AC Maximum 60 Hz115V230V200V230V50 Power Poles4 Power Poles5 Power 018 1 2335 5 127 23 10 10 245 3 1015 25 25 4135 405075100 5270 75100150200500-FOD930500-FOD940 6540 150200300400500-GOD930 7810 300600600500-HOD930 81215 450900900500-JOD930 92250 80016001600500-KOD930 See page 5 for NEMA sizes !


Related search queries