Safety ControlRelays TheSafe SolutionBulletin 700s -CFBulletin 700s -PBulletin 700s -CFBulletin 700s -PRockwell Automation introduces a new category of relaysdesigned to meet the latest and emerging worldwide safetystandards. These safety control relays offer special features to enable you to design safe control circuits with current ratings up to 20 700s Safety Control Relays provide mechanically-linked contacts on all poles. Mechanically-linked contacts are required infeedback circuits for modern safety applications, such as e-stops,safety gates, light curtains, and master control ContactsThis feature allows detection of a welded contact contacts are linked together; they are notindependent.

Bulletin 700S-CF Safety Control Relays 6 Specifications, Continued Control Circuit For 9V DC, code ZR, use operating voltage 0.65… 1.3 x U s. For 24V DC, code ZJ or DJ, use operating voltage 0.7… 1.25 x Us. General 8 kV for main poles, 6 kV for front aux. contacts. 40 degree max. for 700S-CF350 with DC coil.

Tags:

  Automation, Circuit, Rockwell automation, Rockwell, 700s

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Bulletin 700S-CF Bulletin 700S-P - Rockwell Automation

1 Safety ControlRelays TheSafe SolutionBulletin 700s -CFBulletin 700s -PBulletin 700s -CFBulletin 700s -PRockwell Automation introduces a new category of relaysdesigned to meet the latest and emerging worldwide safetystandards. These safety control relays offer special features to enable you to design safe control circuits with current ratings up to 20 700s Safety Control Relays provide mechanically-linked contacts on all poles. Mechanically-linked contacts are required infeedback circuits for modern safety applications, such as e-stops,safety gates, light curtains, and master control ContactsThis feature allows detection of a welded contact contacts are linked together; they are notindependent.

2 If a contact welds, all contacts remainopen. If a contact welds, all contacts remain ContactsThis design provides better protection against contact weldingthan a single break design. It offers greater DC load breakingcapability and better isolation. This feature also providesseparation of and circuits. Double-break contacts openthe circuits in two places, creating two air gaps and reducing theprobability of welded contacts by more that 50% compared to a single-break IdentificationThe red faceplate allows easy identification of safety devices.

3 This face place displays the IEC 60947-5-1 mechanically-linked anti-tamper feature ensures the long-term integrity of yoursafety system. All contact blocks are permanently fixed to ensurethat the safety function is not jeopardized. Manual operation andfield modifications are ProfileSafety Control RelaysDesigned To Meet Worldwide Safety Standards700S-CF (8 pole) 700S-P (4 12 pole)IEC mechanically-linked symbolDouble-break contactsreduce the probability of awelded 700s -CFSafety Control Relays0 Bulletin 700S-CF Positively guided/mechanically linked contacts Mechanically-linked contacts symbol prominently displayed on front Red face plate 8 poles, all permanently attached Ideal for use in safety circuits AC and DC operating coils SUVA third-party certificationTABLE OF CONTENTSD escriptionPageDescriptionPageProduct Selection.

4 4 Dimensions .. 7 Specifications ..5 DescriptionBulletin 700S-CF Safety Control Relays provide mechanically linked, positively guided contacts, which are required in feedback circuits for modern safety applications. The positively guided auxiliary contacts will not change state if a contact welds. Use with safety relays to expand output order must include: Cat. No. of the relays required, complete with coil suffix. Cat. No. of adder decks, timers and accessories required. If required, the part number of replacement to StandardsApprovalsIEC 947-5-1CE CertifiedEN 50011, EN 50005, EN 50022 CSA Certified UL 508UL Listed, File E14840, Guide NKCRVDE 0660 SUVA Third Party CertifiedCSA Part 14 Bulletin 700s -CFSafety Control Relays4 Product SelectionType S-CF Safety Control Relays 8-Pole AC and DC Coil Voltages AC Coil Voltage Suffix Code DC Coil Voltage Suffix Code When ordering DJ coil with built-in surge suppression, remove Z from the Cat.

5 No. Example: Cat. No. 700s -CF440Z C becomes Cat. No. DiagramsContacts700S-CFAC CoilsDC CoilsMainContactsAuxiliary ContactsCat. No. Cat. No. C700S-CF620Z C53700S-CF530 C700S-CF530Z C44700S-CF440 C700S-CF440Z C35700S-CF350 C700S-CF350Z CVoltage122432364248100100-1101101201272 00200-220208208-240220-23050 HzRKVWXYKP DPSKG F60 HzQJ V X KP D KGHL 50/60 Hz KJ KYKP KD KG Voltage230230-240240277347380380-4004004 00-41544048050055060050 Hz VAT N GB MC 60 Hz ATIE NB C50/60 HzKF KA KN KB Voltage912243648606472801101151252202302 50 StandardRQJWYZBGEDPSAFTWith diode suppressor DJ

6 3334K15453626174738483545362617473848354 536261747384833334K154536261727184833334 K154536261727182813334K15 Bulletin 700s -CFSafety Control RelaysSpecificationsGeneral For sixteen or more strands, end ferrule is required. Defined in IEC 947-5-1 annex L. Mechanically-linked is a relationship between contacts of opposite types ( , and ). If the accessory is a pneumatic timer or latch, there is no mechanically-linked guidance; the accessory contacts are independent. Cat. No. 700s -CFmain poles front auxiliary contactsContact Ratings NEMAA600, P600A600, Q600UL General Purpose Current20A!

7 0 AMinimum Contact Rating17 mA20 24V20 mAContact Ratings IEC AC-15 (solenoids, contactors) at rated voltageIEC 947, EN 6094724V15 A6 A48V15 A6 A120V14 A6 A240V10 A5 A400/415V5 A3 A480 A690V1 AAC-12 (Control of AC resistive loads)IEC 947, EN 6094740 CIth20 A10 A230V10 kW400V17 kW690V30 kW60 CIth20 A6 A230V8 kW400V14 kW690V24 kWDC-12(Control of DC resistive loads)IEC 947EN 6094724V12 A12 A48V9 A9 ADC-13 IEC 947, EN 60947, Solenoids and contactors24V5 A5 A48V2 A2 AAvg-Mechanical Life (ops)[Mil]1515 Average-Electrical Life(ops)AC-15 (240V, 3 A)

8 [Mil] Cross-SectionsTerminal TypeTerminal Size per IEC 947-12 x A42 x A4 Solid/Stranded 1 or 2 Conductor Conductor[mm2][mm2] Wire Size per UL/CSA[AWG] Torque[ ] Torque[N m] Location of welded contactsState of Contacts if contact weldsMain Front side side OpenOpenFront OpenOpenLeft side OpenOpenRight side OpenOpen Mechanically -linked Contacts Bulletin 700s -CFSafety Control Relays6 Specifications, ContinuedControl circuit For 9V DC, code ZR, use operating voltage x Us.

9 For 24V DC, code ZJ or DJ, use operating voltage x 8 kV for main poles, 6 kV for front aux. contacts. 40 degree max. for 700s -CF350 with DC coil. Operation in 70 C ambient is permitted with current reduction of 15% below rated valuesCat. No. 700s -CFOperating VoltageAC 50/60 HzPickup[x Us] [x Us] Pickup[x Us] [x Us] Consumption at nominal voltageAC 50/60 HzInrush [VA/W]70/50 Seal [VA/W]8 warm coil[W] cold coil[W] TimesAC 50/60 HzPickup Time[ms] Time[ms] Time[ms] Time[ms] integrated suppression[ms] diode suppression[ms] No.

10 700s -CFRated Insulation Voltage UiIEC690 VUL; CSA600 VDielectric Withstand Voltage2500 VRated Impulse Strength Uimp8 kV Rated Voltage UeAC115, 230, 400, 500, 690 VDC24, 48, 110, 220, 440 VShort- circuit Protection IEC 947-5 Fuse-Type GG20 ARated Frequency50/60 Hz, DCAmbient TemperatureStorage +80 C ( F)Operation at nominal current +60 C ( F) Corrosion Resistancehumid-alternating climate, cyclic, per IEC 68-2-30 andDIN 50 016, 56 cyclesAltitude2000 m above mean sea level, per IEC 947-4 Type of ProtectionIP2X in connected stateFinger Protectionsafe from touch by fingers and back of hand per VDE 0106, Part 1007 Bulletin 700s -CFSafety Control RelaysDimensionsAC Safety Control RelaysDC Safety Control Relays All Cat.