Bulletin 931 Signal ConditionersTechnical DataBulletin 931 Signal Publication 931-TD001D-EN-PTable of Contents/Product Line OverviewIntroduction to Signal Conditioners ..4 Catalog Number Explanation ..6 Product Overview ..7 Product Selection ..11 Accessories ..37 Dimensions ..38 Glossary ..41 Product Line OverviewBulletin931-H931-S931-UTypeHigh- Density Signal ConditionersStandard Signal ConditionersUniversal Signal ConditionersFeatures Cost-effective analog Signal conditioning ina high-density (6 mm wide) housing Provide solutions for a wide variety ofanalog signals Available in compact sizes ranging mm to mm wide. Programmable allowing the devices tobe used on a wide variety of analogsignals Two models are available, one housing mm wide, the other is 45 mm wideProduct Selection by Function TypeCurrent/VoltagePage 11 Page 14 Page 35 RTDPage 21 Page 23 Page 35 ThermocouplePage 24 Page 26 Page 35 Line-Monitoring Page 27 Bridge Page 32 Frequency Page 33 Page 35 HARTPage 34 isit for more information on our Signal Conditioners .

Conditioner. For example, where a liquid volume indicator is needed for filling a bulk storage tank, but the measurement is level (level to volume conversion depends on the shape of the tank). The remaining I/O available in an existing system does not provide for the input type of the sensor required.

Tags:

  Bulk

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Bulletin 931 Signal Conditioners Technical Data

1 Bulletin 931 Signal ConditionersTechnical DataBulletin 931 Signal Publication 931-TD001D-EN-PTable of Contents/Product Line OverviewIntroduction to Signal Conditioners ..4 Catalog Number Explanation ..6 Product Overview ..7 Product Selection ..11 Accessories ..37 Dimensions ..38 Glossary ..41 Product Line OverviewBulletin931-H931-S931-UTypeHigh- Density Signal ConditionersStandard Signal ConditionersUniversal Signal ConditionersFeatures Cost-effective analog Signal conditioning ina high-density (6 mm wide) housing Provide solutions for a wide variety ofanalog signals Available in compact sizes ranging mm to mm wide. Programmable allowing the devices tobe used on a wide variety of analogsignals Two models are available, one housing mm wide, the other is 45 mm wideProduct Selection by Function TypeCurrent/VoltagePage 11 Page 14 Page 35 RTDPage 21 Page 23 Page 35 ThermocouplePage 24 Page 26 Page 35 Line-Monitoring Page 27 Bridge Page 32 Frequency Page 33 Page 35 HARTPage 34 isit for more information on our Signal Conditioners .

2 Bulletin 931 Signal Conditioners4 Visit our website: 931-TD001D-EN-PIntroductionAnalog Signal Conditioner FunctionalityAnalog Signal Conditioners are designed for use with Rockwell Automation I/Osystems to provide reduced installation and maintenance costs in processapplications. The products are available with two way isolation (between inputand output) or three way isolation (between input, output and power). Isolation of analog measurement and control signals with 2 way isolation(between input and output) or 3 way isolation (between input, output and power). Conversion of analog signals from voltage to current. ( to mA,etc.) Amplification, linearization, and transmission of low level sensor signals ( , mVsignals from thermocouples, etc.). Transmission of analog signals over long distances Provides local display using a splitter or remote status indications and alarms viarelay contact closures based on the analog ApplicationsAnalog Signal Conditioners are used wherever temperature, pressure, level, flow, weight, speed, etc.

3 Is measured and controlled as part of acontinuous or batch production process. Analog Signal Conditioners help to prevent these measurements from being degraded on their wayfrom the field to the control room by providing protection from external influences or problems that result from the installation methods industries include power plants, steel production, water and wastewater plants, oil and gas production, and chemical ArchitectureScalable .. Multi-disciplined .. Information EnabledThe Rockwell Automation Integrated Architecture system improves your productivity and reduces total cost of ownership by providingunparalleled functionality, flexibility and scalability. Using sophisticated control, networking, visualization and information technologies, theIntegrated Architecture addresses a full range of control and information needs for discrete, motion, process and batch control, drive control,and safety Signal ProcessingAnalog signals involve the measurement of constantly changing physical operating characteristics which come in many different forms, themost common of which are temperature and pressure.

4 These signals are often found in processes that involve harsh industrial environments orare exposed to the elements. Such environmental conditions can significantly affect the quality of the transmitted Signal and are also constantlychanging themselves. Additionally, such industrial processes often require that these signals are able to be accurately transmitted over these and a variety of other reasons, analog Signal conditioning is often required between the measuring instrumentation and thecontrol system. Analog Signal conditioning is a long established practice in many process industries such as oil and gas processing,pharmaceutical and chemicals industries and standardized electrical signals are normally used. Currents of mA or mA and voltagesof V DC are the most often specified by controls engineers. Bulletin 931 Signal Publication 931-TD001D-EN-PIntroductionProblem solvers for process the wide variety of analog I/O available with today s modern industrial and process controlsystems, some may question why Analog Signal Conditioners are used.

5 Here are a few examples ofwhy an Analog Signal Conditioner might be desirable or required in an installation. Local Alarm/IndicationMany analog signals are passed to local indicators and alarms, which then need to be isolated fromeach other. Long Distance TransmissionInstead of running expensive cable to the control system ( , thermocouples for temperature), AnalogSignal Conditioners can isolate and convert to a high level Signal that is easier to transmit ( , ). Non-Isolated Analog I/O If the existing control system does not provide isolated analog inputs, a separate Analog SignalConditioner will often be used to provide Signal isolation when required , if the control systemneeds to be protected from electrical noise pulses on its analog inputs. Isolation of the Power SourceWhere the control system cannot provide power for the sesnor / transmitter, it is often convenient toprovide isolation of the power source using an Analog Signal Conditioner.

6 Local Display and LinearizationWhen a dedicated local display is required, the analog Signal can be split using an Analog SignalConditioner. For example, where a liquid volume indicator is needed for filling a bulk storage tank, butthe measurement is level (level to volume conversion depends on the shape of the tank). The remaining I/O available in an existing system does not provide for the input type of thesensor required. Example: The remaining I/O in the control system requires a analog inputs and the sensorsprovide less common signals , , , , , mA, A (AC), 931 Signal Conditioners Product RangeRockwell Automation offers a wide range of products to condition analog signalsaccording to industry standards. The Bulletin 931 Analog Signal Conditioners alsoprovide the necessary isolation of the field measurement device from the controlleras well as from any external power supplies.

7 Such isolation prevents interferencethat can occur due to ground loops or common mode noise. The wide range ofAllen-Bradley Bulletin 931 Analog Signal Conditioners completely covers thefunctions involved in analog Signal conversion, isolation, and monitoring. Theproduct range addresses nearly all applications in industrial measuring technologyand safeguards the elementary functions between field signals and control products are easily mounted on 35 mm DIN rail and come in standardelectronic housings with widths of 6, , , , or 45 Signal ConditionersBulletin 931 Signal Conditioners 6 Visit our website: 931-TD001D-EN-PIntroductionAnalog Signal ProcessingAnalog signals involve the measurement of constantly changing physical operating characteristics which come in many different forms, themost common of which are temperature and pressure. These signals are often found in processes that involve harsh industrial environmentsor are exposed to the elements.

8 Such environmental conditions can significantly affect the quality of the transmitted Signal and are alsoconstantly changing themselves. Additionally, such industrial processes often require that these signals are able to be accurately transmittedover long IsolationAnalog Signal Conditioners with 2-way isolation separate the inputand output signals from each other electrically and decouple themeasuring circuits. Potential differences caused by long line lengthsand common reference points are eliminated. The electricalseparation also protects against irreparable damage caused by overvoltages as well as inductive and capacitive interference. U/IVcThree-Way IsolationU/IAnalog Signal Conditioners with three-way isolation separate thesupply voltage from the input and output circuits as well andenables the analog circuit to operate with just one operatingvoltage.

9 I IPassive IsolationAnalog Signal Conditioners with passive isolation offer an additionaladvantage in that they do not require an additional voltage power supply to the analog Signal conditioner can be providedeither by the input or output circuit. This current loop feed ischaracterized by very low power Measurement PT100PT100A number of analog Signal Conditioners are available for temperaturemeasurements. For example, PT100 signals in 2-, 3- and 4-wiresystems are converted into standard mA, mA and signals. U/IVcTemperature Measurement ThermocouplesAnalog Signal Conditioners for connecting conventionalthermocouples are fitted with cold trap compensation as devices amplify and linearize the voltage Signal provided bythe thermocouple. This guarantees accurate analog signalconditioning while eliminating sources of interference or error. U/I fVcFrequency ConversionAnalog Signal Conditioners are available to convert frequencies intostandard analog signals.

10 Downstream controls can therefore directlyprocess pulse strings for measuring rpm or speed. U/ISchalt I AC/DCVcCurrent MonitoringAnalog Signal Conditioners are available for current monitoring forcurrents up to 60A AC or DC. These devices cause a switchedoutput to be triggered by currents above or below the set value andmay also provide analog outputs for continuous monitoring of theload U AC/DCVcVoltage MonitoringAnalog Signal Conditioners are available for voltage monitoring ofboth AC and DC voltages. Voltage fluctuations due to switchingprocesses or overload conditions can be detected for voltagesabove or below the user-defined switching threshold. Bulletin 931 Signal Conditioners7 Visit our website: 931-TD001D-EN-PCatalog Number ExplanationCatalog Number Explanation931S A1A1N-IPNabcd-efaCodeDescriptionHHigh-de nsity SStandardUUniversalbInput TypeCodeDescriptionCurrentA10(4).