BULLETIN DP-1100-06 Series 500 “dia-PUMP” - ES2 Inc.

Series 500 dia-PUMP BULLETIN DP-1100-06 Series 500 dia-PUMP Innovative design, quality workmanship, long-term PUMP CO., Oil By-passTMstroke adjustment allowsbetter valve performance than variable linkagedesigns. The valve checks have extra time toseat even in heavy liquids since they are idleduring the by-pass portion of the suction and discharge It WorksHollow piston reciprocates within a rod fits into the piston. Note the frontof the piston, or nose , has a reduced liquid seal forms at where the full diameter of the piston contacts the the piston moves forward, oil by-passes overthe reduced nose, through port to the center ofthe piston and back to the gearbox. As the pistoncontinues forward, port is blocked by the tip ofthe metering rod stopping the by-pass. Oil is now pushed through port to the Series 500 dia-PUMP The only pumps with EZE-CLEANTMV alvesHydraulically balanced Teflon diaphragm eliminates diaphragmstress associated with mechani-cally flexed Cartridges can be removedfor cleaning withoutdisturbing the piping to the whilerunning through100% of range bymicrometer relief valve protects pump and spring providesback pressure when

Series 500 “dia-PUMPBULLETIN DP-1100-06 Innovative design, quality workmanship, long-term reliability. YEAR WARRANTY 3 CHEMICAL PUMP CO., INC.

Tags:

  Series, Pumps, Bulletin, 1010, Bulletin dp 1100 06 series 500 dia pump, Series 500 dia pump, Bulletin dp 1100 06

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of BULLETIN DP-1100-06 Series 500 “dia-PUMP” - ES2 Inc.

1 Series 500 dia-PUMP BULLETIN DP-1100-06 Series 500 dia-PUMP Innovative design, quality workmanship, long-term PUMP CO., Oil By-passTMstroke adjustment allowsbetter valve performance than variable linkagedesigns. The valve checks have extra time toseat even in heavy liquids since they are idleduring the by-pass portion of the suction and discharge It WorksHollow piston reciprocates within a rod fits into the piston. Note the frontof the piston, or nose , has a reduced liquid seal forms at where the full diameter of the piston contacts the the piston moves forward, oil by-passes overthe reduced nose, through port to the center ofthe piston and back to the gearbox. As the pistoncontinues forward, port is blocked by the tip ofthe metering rod stopping the by-pass. Oil is now pushed through port to the Series 500 dia-PUMP The only pumps with EZE-CLEANTMV alvesHydraulically balanced Teflon diaphragm eliminates diaphragmstress associated with mechani-cally flexed Cartridges can be removedfor cleaning withoutdisturbing the piping to the whilerunning through100% of range bymicrometer relief valve protects pump and spring providesback pressure when pumpingagainst low Refill mechanismoperates once per trainoperates in oil forextended the micrometer dial moves the metering rod and changes the pump capacity.

2 When the metering rod is moved in, the tip of the metering rod closes port sooner in the stroke allowing for less by-pass and more pumping , when the metering rod is moved out, the tip of the metering rodcloses port later in the stroke allowing more by-pass and less motion of the piston pushes and pulls the hydraulic fluid through port ,into and out of the diaphragm chamber. The action of the fluid pushes andpulls the diaphragm which, in turn, pushes and pulls chemical through port .The action of the check valves controls the direction of the liquid. 3 50/60 Hz, 110/220 V Explosion-proof (be certain to order propermotor for hazardous locations) Unit follows 4-20 mA or 1-5V signal Adjustable ratio signal to stroke 1:2 or 2:1 Direct (forward) or indirect (reverse)response to changing signal Manual override in event of instrumentsignal or power loss, a unique featureNote.

3 Can be added on only one head of duplex Control OptionsPNEUMATICSTROKE CONTROLThe flow rate of any Neptune dia-PUMP can be controlled by an instrument air signal when using the pneumatic stroke control to change stroke CONTROLThe flow rate of any Neptune dia-PUMP can be controlled auto-matically by a process instrument usinga variable speed drive to change pumpstroke 56C frame motor flangeadapter allows convenient mounting of any AC or DC variable speed motorcontrol : Select pump with stroking speed sufficiently high that, at minimum speed, pump operates at 15spm HYPOCHLORITEGAS BLEEDS pecial head designed with an automatic air release valve to vent gas accumulation from chemicals that off gas such as sodium hypochlorite. Refer to AR models found in BULLETIN DP-500E. Explosion-proof (be certain to order proper motor for hazardous locations) Unit follows 3-15 psi signal as standard; other signal ranges are available Direct (forward) or indirect (reverse) response to changing signal Local stroke position indicator on controllerNote: Can be mounted on both heads of duplex CONTROLThe flow rate of any Neptune dia-PUMP can be controlled automatically by a process instrument, or manually from a remote location, using the Electric Stroke Control to change stroke Neptune Electric Stroke Control is a one-piece, self-contained Electric Positioner mounted on the pump.

4 (See BULLETIN ESC for complete details and ordering information.)4 Neptune Series 500-A dia-PUMP Series 500-A dia-PUMP DimensionsExcept Kynar Models (Code N8)*Dimensions are approximate. Specifications subject to change without notice.*See BULLETIN DP-500E for Kynar (N8).Features Standard Motor TEFC:1/3HP-1ph-115 VAC-60c-Totally Enclosed Fan-Cooled withbuilt-in automatic thermal overload Ten turn micrometer dial calibrated in 1% increments. Bright color contrasted dial protected from corrosion byclear PVC covering. Stroke mechanism moves only when adjustment is made,eliminating wear. Piston is powered through complete stroke length at allcapacity adjustments eliminating stress, wear and shockof lost motion MODEL515-E-N8 STANDARD MOTOR (METAL HEAD)FLANGE MOUNT MOTOR (METAL HEAD)PVC HEAD (N5)5 Series 500-A dia-PUMP SELECTION CHARTS tandard Motor: 1/3HP-1ph-115 VAC-60c-TEFC SIMPLEX ONLYCAPACITYMATERIALSMAXIMUMPISTONSTROKE SSHIPPINGMODELAT 100 PSIOFPRESSUREDIAMETERPERWEIGHTNUMBERGPHL PHCONSTRUCTIONPSIKG/CM2(INCHES) **Kynar**15011515-A-N1 Cast *PVC*40028515-E-N8**Kynar**15011520-A-N1 Cast **Kynar**15011522-A-N1 Cast *PVC*40028522-E-N8**Kynar**15011525-A-N1 Cast *PVC*40028525-E-N8**Kynar**15011530-A-N1 Cast **Kynar**15011532-A-N1 Cast **Kynar**15011535-A-N1 Cast **Kynar**15011 See page 10 for motor options available.

5 *For sodium hypochlorite service, refer to BULLETIN DP-500E.** Kynar models do not include Eze-CleanTMvalves.** See BULLETIN DP-500E for Higher Capacitiessee page Higher Capacities and Pressuresrequest BULLETIN Ultra-Low Capacity High Pressure Modelsrequest BULLETIN Viscous Chemicals and Slurriesrequest BULLETIN TP or Economy Modelsrequest BULLETIN Series 500 dia-PUMP Series 500 dia-PUMP Dimensions**Dimensions are approximate. Specifications subject to change without METAL HEADWITH PVC HEADF eaturesSeries 500 has the same features as Series 500-A (see page 4) exceptthese models can be duplexed. Any duplex combination can be created using any models on pages 7 and 8, as long as both have the same stroking speed.(Add 15 lbs. to shipping weight.)MODEL 515-S-N3-TE1with low profile flange adapterMODEL535-D-N5 MODEL525-S-N3 STANDARD MOTORFLANGE MOUNT MOTORDUPLEXSTANDARD MOTORFLANGE MOUNT MOTORDUPLEX7 Series 500 dia-PUMP SELECTION CHARTS tandard Motor: 1/3HP-1ph-115 VAC-60c-TEFC DUPLEX AVAILABLE Change the letter S in the model number to the letter D to define a duplex pump with bothheads the same.

6 Any duplex combination can be created using any models on pages 7 and 8, as long as both have the same stroking 100 PSIOF1 4OR 1 3 MOTOR1 2HP MOTOR*DIAMETERPERWEIGHTNUMBERGPHLPHCONST RUCTIONPSIKG/CM2 PSIKG/CM2(INCHES)MINUTESTYLELBS.**500-S- N1 Cast Iron100070N /AN /AN /AN /A515-S-N1 Cast Iron110077N /AN /AN /AN /A520-S-N1 Cast /AN /A530-S-N1 Cast /AN /A535-S-N1 Cast /AN /A537-S-N1 Cast /AN /A547-S-N1 Cast Iron2001435025547-S-N3 316SS2001435025547-S-N4 PVC2001430021 Models 547 furnished with integral 1/2HP-1ph-115 VAC-TEFC motor as standard.*Neptune recommends that 1 2HP high pressure models be used only in flooded suction applications.** Standard motor only. For flange mounted motor, add 20 Higher Capacitiessee page Higher Capacities and Pressuresrequest BULLETIN Ultra-Low Capacity High Pressure Modelsrequest BULLETIN Viscous Chemicals and Slurriesrequest BULLETIN TP or Economy Modelsrequest BULLETIN 560 dia-PUMP Dimensions**Dimensions are approximate.

7 Specifications subject to change without Series 560 dia-PUMP Series 560 dia-PUMP SELECTION CHARTS tandard Motor: 1/2HP-1ph-115 VAC-60c-TEFC DUPLEX AVAILABLE Change the letter S in the model number to the letter D to define a duplex pump with bothheads the same. Any duplex combination can be created using any models on pages 7 and 8, as long as both have the same stroking 100 3HP*1 2HP*3 4HP*1 HP* CONSTRUCTION (INCHES) MINUTEPSIKG/CM2 PSIKG/CM2 PSIKG/CM2 PSIKG/CM2 STYLE*LBS.* , , ,2567-S-N8 Kynar2 For optional motors rated 1 2HP and larger, add FA flange adapter option, plus 56C end mount motor of choice.*Standard motor only. For flange mounted motor, add 20 Models 150 psi Maximum; 125 F and Kynar models do not include Higher Capacities and Pressuresrequest BULLETIN Motor Options Availablesee page 560 has the same features as Series 500-A (see page 4) except these models can be duplexed.

8 Any duplex combination can be created using any models on pages 7 and 8,as long as both have the same stroking speed.(Add 30 lbs. to shipping weight.)STANDARD MOTOR (METAL HEAD)FLANGE MOUNT MOTOR (METAL HEAD)PVC & KYNARHEADDISCHARGE11 2" NPTSUCTION11 2" NPT51 4"[133]21 4"[57]35 8"[92]9 PLANNING YOUR INSTALLATIONN eptune offers a double diaphragm leakdetection option for applications wherecontamination of the process fluid by the pumphydraulic fluid cannot be tolerated or wherediaphragm failure must be sensed Neptune double diaphragm design usestwo dry coupled diaphragms. The areabetween the diaphragms is pumping action is transmitted fromone diaphragm to the other without the use of any intermediate diaphragm condition is monitored by apressure switch which can be wired to shut offthe pump and/or sound a remote alarm.

9 Thisdesign eliminates conductivity probes whichcould fail to detect the presence of oil or low conductivity liquids in the event of adiaphragm double diaphragm option DD is availableon all Neptune Series 500, Series 500-A orSeries 560 dia- pumps .Contact the factory for full specifications andapplications WithLeak DetectionMODEL 522-A-N3-DDDo not oversize the pump. A metering pump should besized so the maximum expected flow rate is 80% to 85%of the pump capacity. The minimum capacity should neverbe planned less than 10% of the pump nameplate outdoor applications the pump motor should besheltered from direct sunlight to prevent overheating. The pump will operate in freezing temperature providedit runs continuously and provided the liquid beingpumped will not dust, which can ignite, as well as fumes or vaporswhen determining if a hazardous environment use a suction strainer 40 60 mesh to preventforeign matter from clogging the check suction and discharge isolation valves formaintenance.

10 Select large port, quick opening Column A suction draw down column is the most accurate and convenient method to measurepump Valve The internal relief valve furnished withthese pumps is to protect the pump. Provide an externalrelief valve to protect the system pressure valves are required when the system doesnot provide sufficient back pressure. Do not depend on aspring-loaded check valve when feeding from bulk tanksto a low-pressure application where the discharge isbelow the dampener is used when long discharge runs(between the pump and injection point) need dampeningto reduce water-hammer or pressure spikes caused byacceleration in the discharge Piping Keep the piping as short as possible,minimizing bends, elbows and other restrictions. Thesafest rule of thumb is to use piping one size largerthan the pump suction connection.