1 TECHNICAL DESCRIPTION GloEn-PatrolTM Ballast Water Management System.

2 #1559-3, Songjung-Dong, Gangseo-Gu, Busan, Korea / TEL : +82-51-831-1010 / FAX : +82-51-831-1399 / E-mail : TECHNICAL DESCRIPTION Of GloEn-PatrolTM Ballast Water Management System PROJECT : Yacht Hotel Ship SHIPYARD : Boustead Naval Shipyard SHIPOWNER : Sunborn Internation PUMP CAPACITY : 250m3/hr 1 set Skid Type DATE : Apr.

3 20th, 2011 PANASIA CO., LTD. Tel : +82-51-831-1010 Fax : +82-51-831-1399 E-mail : Web : TECHNICAL DESCRIPTION GloEn-PatrolTM Ballast Water Management System.

4 #1559-3, Songjung-Dong, Gangseo-Gu, Busan, Korea / TEL : +82-51-831-1010 / FAX : +82-51-831-1399 / E-mail : I.

5 SYSTEM GENERAL PANASIA s GloEn-Patrol Ballast Water Management System Type approved by administration in compliance with the Guidelines for approval of Ballast Water Management System(G8) of Res. (53) and by IMO MEPC in accordance with the Procedure for approval of Ballast Water Management System that make use of Active Substance(G9) of Res. (53). GloEn-Patrol BWMS is a combined treatment system taking advantage of Filter and UV units most environmentally friendly and optimally designed for every kind of vessels. Adopting a 100% physical treatment technology, GloEn-Patrol effectively disinfects harmful aquatic organism and pathogen in water without generating any toxic substance during ballasting and de-ballasting.

6 In addition, the Filter unit not only eliminates organisms larger than 50 micrometer but makes sediment in ballast tank minimized. The main purpose of filtration is to maximize the efficacy of disinfection of UV unit by improving transmittance of UV light. Features of GloEn-Patrol BWMS 1. The most environmental friendly system 2. Compact design 3. Automatic back flushing and auto wiping 4. No toxic by-products 5. Very simple operation 6. Easy and economical maintenance 7. No corrosion problem 8. Less inflow of sediment TECHNICAL DESCRIPTION GloEn-PatrolTM Ballast Water Management System.

7 #1559-3, Songjung-Dong, Gangseo-Gu, Busan, Korea / TEL : +82-51-831-1010 / FAX : +82-51-831-1399 / E-mail : II.

8 TECHNICAL SPECIFICATION GloEn-Patrol BALLAST WATER MANAGEMENT SYSTEM Model : GloEn-P250 Supply Voltage : AC 440V, 3 PHASE Air Supply : 7 kg/cm2 Ballast pump capacity : 250m3/hr Treatment Capacity : 250m3/hr Power Consumption : 27 Kw Foot print : m2 PRESSURE LOSS : ~ kg/cm2 The system will be operated for treatment through both the Filter unit and UV unit during ballasting and only through the UV system during de-ballasting. < Ballasting Operation > TECHNICAL DESCRIPTION GloEn-PatrolTM Ballast Water Management System.

9 #1559-3, Songjung-Dong, Gangseo-Gu, Busan, Korea / TEL : +82-51-831-1010 / FAX : +82-51-831-1399 / E-mail : < De-ballasting Operation > Consist of ; 1.

10 FILTER UNIT The water enters through the inlet pipe into the filter area and flows through the cylindrical filter element from inside out. The filtration cake accumulating on the element surface causes pressure differential to develop across the filter element. When this pressure difference reaches a pre-set value, the back-flushing mechanism is operated. The back-flushing begins when the filter element reaches a pre-set value or a pre-determined lapse of time. The back-flushing takes between 10 to 30 seconds. During the back-flushing cycle the filtered water is not interrupted and continues to flow downstream of the filter in the normal manner. Specification ; Model : PF250 Primary Treatment for removing large plankton over 50 Rises UV light transmission Automatic back flushing Filtration grade : 50 micron Flow rate : 250 m3/hr Working pressure for back flushing : 2 bar TECHNICAL DESCRIPTION GloEn-PatrolTM Ballast Water Management System.