C05. S02. P02 – P30 ShaftWall - british-gypsum.com

C05. S02. P02 P30 ShaftWall Including C05. S01. P02 Specialist partitions introduction This section includes updated information, added since it was first published in December 2015. Last updated 28/11/2018!C05 IntroductionSpecialist partitionsSpecialist partitionsThis section details specialist lightweight systems where high-security, curved, fire or blast resistant partitions are requiredC05. S01. P02 0115 945 6123 partitionsSpecialist partitionsThis section contains our solutions that have performances above and beyond the usual project requirements. Examples are enhanced security, aesthetic appeal and explosion protection. The systems included in this section are:Specific performanceSystemDescriptionPageShaftWal lLightweight, fire resistant structure to protect vertical or horizontal elements in confined spaces, where access is limited to one side wall capable of providing up to 240 minutes fire curveSpecifically designed to provide curved walls and linings with a high degree of design flexibility.

0115 945 6123 bgtechnical.enquiries@bpb.com C05. S02. P04 C05 britsrhh Specialist partitions 1 2 3 4 Detail Partition thickness mm Lining boards to non-shaft side1 Max.

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of C05. S02. P02 – P30 ShaftWall - british-gypsum.com

1 C05. S02. P02 P30 ShaftWall Including C05. S01. P02 Specialist partitions introduction This section includes updated information, added since it was first published in December 2015. Last updated 28/11/2018!C05 IntroductionSpecialist partitionsSpecialist partitionsThis section details specialist lightweight systems where high-security, curved, fire or blast resistant partitions are requiredC05. S01. P02 0115 945 6123 partitionsSpecialist partitionsThis section contains our solutions that have performances above and beyond the usual project requirements. Examples are enhanced security, aesthetic appeal and explosion protection. The systems included in this section are:Specific performanceSystemDescriptionPageShaftWal lLightweight, fire resistant structure to protect vertical or horizontal elements in confined spaces, where access is limited to one side wall capable of providing up to 240 minutes fire curveSpecifically designed to provide curved walls and linings with a high degree of design flexibility.

2 Ideal for creating imaginative spaces with great aesthetic secureLightweight security wall, offering high resistance to determined performance blast refuge system offering resistance to explosive and riser encasement system and linings within confined spacesAll our systems are covered by SpecSure when using genuine British Gypsum and Saint-Gobain Isover productsC05 ShaftWallSpecialist partitionsC05. S02. P02 0115 945 6123 partitionsSystem can be skim finished with Thistle PureFinish. Refer to C02. S01. P49 ShaftWallShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an early stage of the construction without the need for scaffolding.

3 The system can also be built horizontally to provide a fire rated membrane. Key benefits Horizontal membranes are built entirely from below A ShaftWall variant with non-combustible Glasroc F firecase board linings is available High level commonality with GypWall partition components, particularly 70mm stud solutions Higher certainty of installed acoustic performance due to laboratory tests incorporating deflection heads Can be used where access is limited to one side at the head, M & E cages already installed in corridorsmins30120 RwdB3852 You may also be interested assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and easy filtering by performance criteria.

4 It provides system specific downloads including: BIM (Revit) objects CAD details (.dwg) NBS Clauses System and product data sheets Refer to to C01. S01. P07C05. S02. P03 partitions1234 DetailPartition thickness mmLining boards to non-shaft side1 Max. partition height2mmStud sizemmSound insulation RwdB3 Duty rating5 Approx. weight kg/m System referenceBoard typeLining thickness mmNo insulationSealed structure plus 25mm insulation4No insulationWith insulation60 minutes fire resistance (60 minutes integrity / 60 minutes insulation both directions seperately)187 Gyproc FireLine2 x FireLine2 x FireLine2 x FireLine2 x minutes fire resistance (90 minutes integrity / 90 minutes insulation both directions seperately)

5 192 Gyproc FireLine2 x 154500604245 Severe43A306003A3060231102 Gyproc FireLine2 x 154500704245 Severe43A306003A3060231124 Gyproc FireLine2 x 156000924446 Severe44A306006A3060252178 Gyproc FireLine2 x 1560001464850 Severe46A306009A306028120 minutes fire resistance (120 minutes integrity / 120 minutes insulation both directions seperately)3107 Gyproc FireLine3 x 154500604345 Severe55A306030A3060353117 Gyproc FireLine3 x 154500704345 Severe55A306030A3060353139 Gyproc FireLine3 x 156000924546 Severe56A306031A3060364193 Gyproc FireLine3 x 1560001464950 Severe58A306032A306033 For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and easy filtering by performance criteria.

6 It provides system specific information downloads including BIM (Revit) objects. Go to For improved durability and impact resistance, the outer layer of Gyproc FireLine can be replaced with a layer of 15mm Gyproc The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more The acoustic performance figures quoted include ShaftWall partitions with deflection Gyproc CoreBoard and first layer of lining board are bedded onto Gyproc Sealant, as required for pressurised air shafts, in addition to normal Estimated rating from non-shaft side only. The fire resistance and sound insulation performances are for imperforate partitions, but incorporating deflection heads, with all joints taped and filled, or skimmed according to British Gypsum s recommendations.

7 The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover components are used throughout, and the Company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. Gypframe Extra Deep Flange Floor & Ceiling Channel or Gypframe J Channel should be used at the head. For the base Gypframe Folded Edge Standard Floor & Ceiling Channel should be used for heights up to 4200mm, Gypframe Deep Flange Floor & Ceiling Channel should be used for heights between 4200mm and 8000mm, Gypframe Extra Deep Flange Floor & Ceiling Channel should be used for heights in excess of 60, 70 or 92mm I Stud framework with Gyproc CoreBoard between studs, secured by Gypframe Retaining Channel.

8 25mm Isover Acoustic Partition Roll (APR 1200) in cavity (optional). Lining boards to non-shaft side, see table. Studs at 600mm 60, 70 or 92mm I Stud framework with Gyproc CoreBoard between studs, secured by Gypframe Retaining Channel. 25mm Isover Acoustic Partition Roll (APR 1200) in cavity (optional). Lining boards to non-shaft side, see table. Studs at 600mm 146 TI 90 Tabbed I Stud framework with Gyproc CoreBoard between studs, secured by Gypframe Retaining Channel. 25mm Isover Acoustic Partition Roll (APR 1200) in cavity (optional). Lining boards to non-shaft side, see table. Studs at 600mm 146 TI 90 Tabbed I Stud framework with Gyproc CoreBoard between studs, secured by Gypframe Retaining Channel. 25mm Isover Acoustic Partition Roll (APR 1200) in cavity (optional).

9 Lining boards to non-shaft side, see table. Studs at 600mm performanceVertical elementsTable 1a Solutions to satisfy the requirements of BS EN 1364-1 For details of when to specify fire resistance using EN Refer to C02. S01. P05C05. S02. P04 0115 945 6123 partitions1234 DetailPartition thickness mmLining boards to non-shaft side1 Max. partition height2mmStud sizemmSound insulation RwdB3 Duty rating5 Approx. weight kg/m System referenceBoard typeLining thickness mmNo insulationSealed structure plus 25mm insulationNo insulationWith insulation60 minutes fire resistance (when exposed from corridor side fire insulation performance is reduced to 30 minutes)6177 Gyproc FireLine1 x 154200603942 Heavy30A306001A306010187 Gyproc FireLine1 x 154200703942 Heavy30A306001A3060101109 Gyproc FireLine1 x 156000924043 Heavy31A306004A3060112163 Gyproc FireLine1 x 1577001464346 Heavy33A306007A30601390 minutes fire resistance (when exposed from corridor side fire insulation performance is reduced to 60 minutes)

10 6387 Gyproc FireLine2 x FireLine2 x FireLine2 x FireLine2 x minutes fire resistance (when exposed from corridor side fire insulation performance is reduced to 90 minutes)6392 Gyproc FireLine2 x 154500604245 Severe43A306003A3060233102 Gyproc FireLine2 x 154500704245 Severe43A306003A3060233124 Gyproc FireLine2 x 156700924446 Severe44A306006A3060254178 Gyproc FireLine2 x 1579001464850 Severe46A306009A306028 For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to For improved durability and impact resistance, the outer layer of Gyproc FireLine can be replaced with a layer of 15mm Gyproc Based on limiting deflection of L/240 at 200 The acoustic performance figures quoted include ShaftWall partitions with deflection Gyproc CoreBoard and first layer of lining board are bedded onto Gyproc Sealant, as required for pressurised air shafts, in addition to normal Estimated rating from non-shaft side When exposed to fire from the corridor side, the temperature of exposed metal exceeds the requirements of BS 476: Part 22.