CUH-14.. COMMERCIAL HYDRONIC PRODUCTS. A Mestek COMPANY. Cabinet Unit Heaters FOR STEAM AND HOT WATER. Cabinet UNIT Heaters . selection AND "ROUGH IN" MADE EASY - ONLY THE LENGTHS VARY. The pedestal base for floor models is the The Sterling Cabinet Unit Heater is the height of most mop boards. industry's most recent design. Years of manufacturing and engineering experi- Field repainting to match the decor is ence combined with a concern for ap- possible and factory applied decorator pearance have resulted in a crisply styled colors are available as an option.

The wide selection of floor, wall and ceiling . ... neutral eggshell baked powder finish. Back and side panels are 18-gauge. The pedestal base for floor models is the height of most mop boards. Field repainting to match the decor is possible and factory applied decorator ... standard 1/4 turn/philips head fastener and is avail-able with ...

Tags:

  Selection, Fastener, Powder

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Cabinet Unit Heaters - Mestek

1 CUH-14.. COMMERCIAL HYDRONIC PRODUCTS. A Mestek COMPANY. Cabinet Unit Heaters FOR STEAM AND HOT WATER. Cabinet UNIT Heaters . selection AND "ROUGH IN" MADE EASY - ONLY THE LENGTHS VARY. The pedestal base for floor models is the The Sterling Cabinet Unit Heater is the height of most mop boards. industry's most recent design. Years of manufacturing and engineering experi- Field repainting to match the decor is ence combined with a concern for ap- possible and factory applied decorator pearance have resulted in a crisply styled colors are available as an option.

2 Unit that will blend with almost any room decor and provide reliability, durability, Recessed models are provided with a field individual control and quiet operation. installed wall seal that allows for full or partial recessing depending on the model. As unit size increases, only the length The wall seal kit is also available as an changes. The depth and height remain option for full or partial recessing of most constant, thus allowing the designer to other models. have uniformity of appearance when units of various sizes are installed in adjacent The solid state speed control provides areas.

3 Infinite variations from high to low speed, giving the occupant finger tip control over The wide selection of floor, wall and ceiling fan speed and room temperature. units with a variety of air flow arrangements allows for exactly matching design require- All Sterling commercial hydronic products ments. are made from recycled materials. Material recycled contents can be obtained from The standard 16-gauge front panel is your local Sterling representative. rugged enough to withstand harsh treat- ment. Exposed cabinetry is provided with a neutral eggshell baked powder finish.

4 Back All units are CSA. and side panels are 18-gauge. certified. 2. 10 MODELS - 28 ARRANGEMENTS - 8 CFM SIZES. F FI. FLOOR TYPE FLOOR TYPE, INVERTED FLOW. FS FSI. FLOOR TYPE SLOPE TOP FLOOR TYPE SLOPE TOP, INVERTED FLOW. W RW. & &. WI RWI. WALL TYPE and INVERTED FLOW RECESSED WALL and INVERTED FLOW. C RC. CEILING MOUNTED RECESSED CEILING MOUNTED. See page 6 for arrangements. 3. Cabinet UNIT HEATER STANDARD FEATURES. - Adjustable wall seal to suit recessing requirements. - Copper Aluminum coil for steam or hot water. - Support bracket to wall.

5 - Whisper quiet blowers. - Cabinet finish neutral eggshell baked powder . - Leveling legs optional. - Motors - Permanent split capacitor. - 16-Gauge steel front panel with - Permanent washable filter, - Outside air knockout insulation, standard. aluminum fiber media. provided standard on F and FS models. - Speed Control / Access doors - Standard on all floor and wall models. - Steam Coil (Standard) - Brazed copper tube and header with aluminum fin. Factory tested to 250 PSI. - Access Area typical both ends. - Optional High Capacity 2 row coil.

6 4. Cabinet UNIT Heaters . RATINGS AND SPECIFICATIONS. WALL SEAL - The optional wall seal kit with gasket is FRONT PANEL - 16-gauge front panel is standard with designed to allow for easy installation and per- 1/2" - 1-1/2 lb. density, neoprene one side insulation manent protection for the wall board, plaster or in front of the coil. Full panel insulation is available sheet rock surrounding the unit on recessed models. as an option. Tamper resistant fasteners are also available. COILS - STANDARD ONE ROW - The durable mechanically MOTOR/BLOWER SHELF - Support shelf adds support bonded copper/aluminum coil presents the best to units strength and structural integrity.

7 A support of today's hydronic technology. Providing 12 fins per gusset is supplied with 600 CFM units and up. inch with 1/2" nominal diameter tubes, the ultimate in BTU capacity is provided without sacrificing noise, FINISH - Standard finish is an aesthetically pleasing vibration or amp draw. All element assemblies are neutral eggshell baked powder , which is suitable for submersion tested at factory at 250 PSI and are field repainting if necessary. Optional colors avail- rated at a working pressure of 300 PSI All units are able as shown on color chart.

8 Designed so that field modifications can be made to reverse the coil position if required. LEVELING LEG - Optional leveling legs are available. HIGH CAPACITY COIL - This is a hot water coil Four (4) legs per unit allow adjustment for pitch and designed to provide increased capacity when yaw when unit is mounted on uneven floors. the required load exceeds that of the standard coil for a given size. Its construction is similar to the SPEED CONTROL / ACCESS DOOR - The solid state standard coil; however, fins are double depth and speed control allows infinite speed selection for there are two rows of tubes.

9 Element assemblies comfort control. Located under the finger touch are submersion tested at 250 PSI and are rated at a access door, the speed control is out of view yet working pressure of 300 PSI easily accessible. The access door requires just the pressure of a finger to open and swings 120 to a BLOWER FAN ASSEMBLY - The blower fan assembly stay open position. The access door comes with a provides one of the industry's best CFM output per standard 1/4 turn/philips head fastener and is avail- unit size. The sizes range from 200 CFM up to the able with optional tamper resistant fastener .

10 Speed 1400 CFM unit at 115 volts. This is the widest range control switch is not mounted on C or RC units. of sizes in the industry. The Low Noise blower assembly is made with galvanized steel, providing long life ACCESS AREA - A spacious rough-in area is provided and durability. between the unit ends and the internal Cabinet at both ends. The removable front panel allows full MOTORS - Standard motors are (PSC) permanent access to the piping and valve area (left-hand split capacitor. This provides the ultimate in motor standard) and to the wiring, switch area.