Example: bachelor of science

Cable-in / cable-out miniature circuit breakers and ...

Cable-in / cable-out miniature circuit breakers and supplementary protec torsProduct Guide1 eaton CORPORATION Cable-in / cable-out circuit breakers and protectorsCable-in / cable-out miniature circuit breakers and supplementary protectorsEaton offers a complete line of circuit breakers with its WMZT and QC product lines engineered for branch circuit protection and its WMZS product line designed for supplementary protection. Optimum product quality, tested reliability and safety standards for the best protection of personnel, installations and 489 Cable-in / cable-out Branch QC circuit BreakersProduct Overview .. 2 QC circuit breakers .. 2 QCD circuit breakers .. 3 QCR circuit breakers .

EATON CORPORATION Cable-in / cable-out circuit breakers and protectors 1 Cable-in / cable-out miniature circuit breakers and supplementary protectors Eaton offers a complete line of circuit breakers with its WMZT and QC …

Tags:

  Supplementary, Eaton, Breaker, Circuit, Miniature, Protectors, Circuit breakers, Miniature circuit breakers, Miniature circuit breakers and supplementary protectors eaton

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Cable-in / cable-out miniature circuit breakers and ...

1 Cable-in / cable-out miniature circuit breakers and supplementary protec torsProduct Guide1 eaton CORPORATION Cable-in / cable-out circuit breakers and protectorsCable-in / cable-out miniature circuit breakers and supplementary protectorsEaton offers a complete line of circuit breakers with its WMZT and QC product lines engineered for branch circuit protection and its WMZS product line designed for supplementary protection. Optimum product quality, tested reliability and safety standards for the best protection of personnel, installations and 489 Cable-in / cable-out Branch QC circuit BreakersProduct Overview .. 2 QC circuit breakers .. 2 QCD circuit breakers .. 3 QCR circuit breakers .

2 4 QCF circuit breakers .. 5 QCGF circuit breakers .. 6 Accessories .. 7UL 489 Cable-in / cable-out Branch WMZ circuit BreakersProduct Overview .. 9 Product Selection .. 10 WMZT UL 489 circuit breakers 10 kAIC .. 11 WMZH UL 489 circuit breakers 14 kAIC .. 12 Accessories .. 13 Technical Data .. 14UL 1077 Cable-in / cable-out supplementary ProtectorsProduct Overview .. 20 Product Selection .. 21 WMZS B Curve (3 5X In Current Rating .. 22 WMZS C Curve (5 10X In Current Rating) .. 23 WMZS D Curve (10 20X In Current Rating) .. 24 Accessories .. 25 Technical Data .. 26 Accessories .. 29 Technical Data .. 312UL 489 Cable-in / cable-out Branch circuit BreakerQC circuit BreakersPRODUCT OVERVIEWEATON CORPORATION Cable-in / cable-out circuit breakers and protectorsType QC miniature circuit breakers Cable-in / cable-out Type QCFor Cable-in / cable-out Panel-Mount Applications Single-, two-, three- and four-pole options Built and listed to ULT 489 All products UL and CSAT listed All products 10 100A are HACR ratedType QC miniature circuit breakers Cable-in / cable-out Type QC Catalog Numbering System QC 3 020 H breaker TypeQC = QC breakerNumber of Poles1 = Single-pole2 = Two-pole3 = Three-pole4 = Four-poleConstructionH = 240V (two-, three- and four-pole only))

3 Ampere Rating010 = 10A015 = 15A020 = 20A025 = 25A030 = 30A035 = 35A040 = 40A045 = 45A050 = 50A055 = 55A060 = 60A070 = 70A080 = 80A090 = 90A100 = 100 AQUICKLAGT Type QC 10,000 Ampere Interrupting Capacity Thermal-Magnetic BreakersContinuous Ampere Rating at 40 CSingle-Pole120/240 VacCatalog NumberTwo-Pole120/240 VacCatalog NumberThree-Pole240 VacCatalog Number101520QC1010QC1015 QC1020 QC2010QC2015QC2020 QC3015 HQC3020H3040QC1030QC1040QC2030QC2040QC30 30 HQC3040H5060QC1050 QC2050QC2060QC3050 HQC3060H70100 QC1100QC2070QC2100QC3070 HQC3100H Switching duty rated for 120 Vac fluorescent light applications only. For special low-magnetic breaker , order QC1015L1 or :NFor non-automatic switches, see catalog Volume 4: circuit Protection, CA08100005E, Tab 24.

4 UL 489 Cable-in / cable-out Branch circuit BreakerQC circuit BreakersProduct Overview3UL 489 Cable-in / cable-out Branch circuit BreakerQCD circuit BreakersPRODUCT OVERVIEWEATON CORPORATION Cable-in / cable-out circuit breakers and protectorsType QC miniature circuit breakers Cable-in / cable-out Type QCDFor Cable-in / cable-out DIN Rail Mount HVAC Applications Single-, two- and three-pole options Modular construction DIN mounted (symmetrical rail 35 x 7 .5 DIN/EN 50 022) Flexible power feed connection: wire size, position Same breaker size for entire rating range Field-mountable accessories: finger-shroud proof, quick-connect terminals, jumper unitsType QC miniature circuit breakers Cable-in / cable-out Type QCD Catalog Numbering SystemQCD 3 020 H breaker TypeQCD = QCD breakerNumber of Poles1 = Single-pole2 = Two-pole3 = Three-poleConstructionH = 240V (two- and three-pole only)

5 Ampere Rating010 = 10A015 = 15A020 = 20A025 = 25A030 = 30A035 = 35A040 = 40A045 = 45A050 = 50A055 = 55A060 = 60A070 = 70A080 = 80A090 = 90A100 = 100 AQUICKLAG Type QCD 10,000 Ampere Interrupting Capacity Thermal-Magnetic BreakersContinuous Ampere Rating at 40 CSingle-Pole120/240 VacCatalog NumberTwo-Pole120/240 VacCatalog NumberThree-Pole240 VacCatalog Number10152030 QCD1010 QCD1015 QCD1020 QCD1030 QCD2010 QCD2015 QCD2020 QCD2030 QCD3015 HQCD3020 HQCD3030H4050 QCD1040 QCD1050 QCD2040 QCD2050 QCD3040 HQCD3050H6070100 QCD1060 QCD2060 QCD2070 QCD2100 QCD3060 HQCD3070 HQCD3100 HQCD circuit BreakersProduct Overview4UL 489 Cable-in / cable-out Branch circuit BreakerQCR circuit BreakersPRODUCT OVERVIEWEATON CORPORATION Cable-in / cable-out circuit breakers and protectorsType QC miniature circuit breakers Cable-in / cable-out 1/2-Inch Wide Types QCR.

6 QCFWhen Space is at a Premium QCR: For DIN rail mount Cable-in / cable-out applications QCF: For front-mount through-the-door Cable-in / cable-out applications 1/2-inch (12 .7-mm) wide per pole Three-position handle: ON, Tripped (center), OFF Thermal-magnetic protection Single-, two- and three-pole 10 kAIC at 120/240 Vac, 10 60A 10 kAIC at 240 Vac, 10 30 AType QC miniature circuit breakers Cable-in / cable-out 1/2-Inch Wide Types QCR, QCF Catalog Numbering SystemQCR 1 020 T breaker TypeQCR = QCR breaker (rear mount)QCF = QCF breaker (front mount)Number of Poles1 = Single-pole2 = Two-pole3 = Three-poleConstruction/TerminalsH = 240V (two- and three-pole only)T = Ring or spade terminals (10 30A only)

7 Ampere Rating010 = 10A015 = 15A020 = 20A025 = 25A030 = 30A035 = 35A040 = 40A045 = 45A 050 = 50A055 = 55A060 = 60 AQUICKLAG Type QCR breaker 10 kAIC Interrupting Ratings Continuous Ampere Rating at 40 CSingle-Pole120/240 VacCatalog NumberTwo-Pole120/240 VacCatalog NumberThree-Pole 240 VacCatalog Number10 QCR1010 QCR1010 TQCR2010 QCR2010T 15 QCR1015 eQCR1015T eQCR2015 QCR2015 TQCR3015 HQCR3015HT20 QCR1020 eQCR1020T eQCR2020 QCR2020 TQCR3020 HQCR3020HT25 QCR1025 QCR2025 QCR3025 HQCR3025HT30 QCR1030 QCR2030 QCR3030 HQCR3030HT35 QCR1035 QCR2035 40 QCR1040 QCR2040 45 QCR1045 QCR2045 50 QCR1050 QCR2050 55 QCR1055 60 f QCR1060 QCR2060 Standard breaker terminals are box type lugs. breakers with T catalog number suffix are suitable for line and load side ring terminal connection (#10-32 plus/minus terminal screw provided).

8 breakers with P catalog number suffix are suitable for terminating two 10 AWG Quick-Connect type terminals per phase on breaker load side. breakers with shunt trip (extra pole required on breaker right-hand side) are available on single-, two- and three-pole. e All 15 and 20A single-pole breakers are SWD (switching duty) rated for fluorescent lighting 60/75 C Cu/Al wire on all ratings except 60A, which requires Cu only circuit BreakersProduct Overview5UL 489 Cable-in / cable-out Branch circuit BreakerQCF circuit BreakersPRODUCT OVERVIEWEATON CORPORATION Cable-in / cable-out circuit breakers and protectorsType QC miniature circuit breakers Cable-in / cable-out 1/2-Inch Wide, Types QCR.

9 QCFQUICKLAG Type QCF breaker 10 kAIC Interrupting Ratings Continuous Ampere Rating at 40 CSingle-Pole120/240 VacCatalog NumberTwo-Pole120/240 VacCatalog NumberThree-Pole 240 VacCatalog Number10 QCF1010 QCF1010 TQCF2010 QCF2010T 15 QCF1015 QCF2015 QCF3015 HQCF3015HT20 QCF1020 QCF2020 QCF3020 HQCF3020HT25 QCF1025 QCF2025 QCF3025 HQCF3025HT30 QCF1030 QCF2030 QCF3030 HQCF3030HT40 QCF1040 QCF2040 50 QCF1050 QCF2050 60 eQCF1060 QCF2060 Standard breaker terminals are box type lugs. breakers with T catalog number suffix are suitable for line and load side ring terminal connection (#10 32 plus/minus terminal screw provided). breakers with shunt trip attachment (extra pole required on breaker right-hand side) are available.

10 All 15 and 20A single-pole breakers are SWD (switching duty) rated for fluorescent lighting 60/75 C Cu/Al wire on all ratings except 60A, which requires Cu only DescriptionCatalog NumberSteel mounting clip mounts QCR breaker if individual mounting is required. Quantity of two required for single- and two-pole, and four required for three-pole padlock device for single-pole QCR or QCF padlock device for multi-pole QCR or QCF bracket assembly for QCR or QCF single- or multi-pole breakers (OFF only).QCRFLOFFP adlock bracket for QCR, lock-off Type C SpacerQCRSPACERQCR and QCF Ring or Spade Lug Terminals (10 30A ratings only)Factory-installed line and load side terminals each equipped with a #10 32 screw suitable for terminating one 10 AWG wire with insulated ring or spade type terminal as T QCF circuit BreakersProduct Overview6UL 489 Cable-in / cable-out Branch circuit BreakerQCGF circuit BreakersPRODUCT OVERVIEWEATON CORPORATION Cable-in / cable-out circuit breakers and protectorsType QC miniature circuit breakers Cable-in / cable-out 1/2-Inch Wide Types QCGF, QCGFEPFor Cable-in / cable-out Panel-Mount Applications QUICKLAG ground fault circuit breakers , Class A GFCI.