Example: tourism industry

Cables and Wires - Kenoll

Cables and Wires2 Copper cable Company LimitedCopper cable Company is the UK subsidiary of TELE-FONIKA Kable , with offices and a warehouse centrally located in , LPCB ApprovalsFor your safety and peace of mind, our Cables have been tested, verified and approved by the independent third party laboratories, including BASEC and LPCB:A major supplier to the UK and Eire of housewiring, low voltage, power and fire resistant Cables for use in domestic, commercial offices, public buildings and utilities. In addition, we provide bespoke flexible rubber cable solutions for critical temporary power, submersible pumps and trailing cable the telecommunications sector we supply copper and fibre data all your cable requirements we have stock available for immediate despatch from our East Midlands warehouse, for larger quantity shipments we can also deliver directly from our factories where substantial stocks are can trust TELE-FONIKA Kable , our factory management systems are approved to IS09001 for Quality, to ISO14001 for the protection of the Environment and OHSAS18001 for Occupational Health & Safety:3 Leading producer of Cables and cable systemsTELE FONIKA Kable Group has been present on the domestic and international cable industry market for more than 25 years.

Coil Lead 4C Coil Lead Type 4C Cable 78 ARMOURED POWER CABLES 694-X XLPE Armoured PVC Sheathed Cable 81 694-LH XLPE Armoured Zero Halogen Sheathed Cable 88 UNARMOURED POWER CABLE 6181XY Single Core XLPE Insulated, PVC Sheathed Cable 103 6181XB Single Core Zero Halogen Insulated And Sheathed Cable 106 NYY XLPE / PVC

Tags:

  Types, Cable, Sheathed, Insulated, Xlpe, Pvc sheathed, Unarmoured, Xlpe insulated

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Cables and Wires - Kenoll

1 Cables and Wires2 Copper cable Company LimitedCopper cable Company is the UK subsidiary of TELE-FONIKA Kable , with offices and a warehouse centrally located in , LPCB ApprovalsFor your safety and peace of mind, our Cables have been tested, verified and approved by the independent third party laboratories, including BASEC and LPCB:A major supplier to the UK and Eire of housewiring, low voltage, power and fire resistant Cables for use in domestic, commercial offices, public buildings and utilities. In addition, we provide bespoke flexible rubber cable solutions for critical temporary power, submersible pumps and trailing cable the telecommunications sector we supply copper and fibre data all your cable requirements we have stock available for immediate despatch from our East Midlands warehouse, for larger quantity shipments we can also deliver directly from our factories where substantial stocks are can trust TELE-FONIKA Kable , our factory management systems are approved to IS09001 for Quality, to ISO14001 for the protection of the Environment and OHSAS18001 for Occupational Health & Safety:3 Leading producer of Cables and cable systemsTELE FONIKA Kable Group has been present on the domestic and international cable industry market for more than 25 years.

2 A stable development strategy based on a full diversification of outlets enabled the consolidation of our company in the world s leading cable companies with significant development and products provided by TF Kable find numerous applications in the most important industry sectors they include more than 25,000 proven standard construction. Furthermore, they include a specialist assortment tailored to the individual needs of business , our production facilities (in Poland, Serbia and Ukraine), Bukowno-Poland recycling plant and commercial companies demonstrate a significant development potential. They are responsible for the geo-regional distribution of products, as well as modern fire test laboratory in the Krakow-Wielicka plant. This laboratory performs several hundred pre-tests of flammability per year. There is also a laboratory of high and extra high voltages in Bydgoszcz. 4C a b le Ty p eDescription PageFIRE PERFORMANCE CABLESF lamex 1 Single Core Conduit Cable7 Flamex 2 Standard Grade Fire Alarm /Emergency Lighting Cable11 Flamex 2 EEnhanced Grade Fire Alarm/Emergency Lighting Cable15 Flamex 3 unarmoured Multicore Cable19 Flamex 4 Armoured Power Cable23 Flamex 6 Enhanced Armoured Power Cable27 WIRING CABLES6491X /H07V-RSingle Core PVC insulated Cable326 491B / H 07 Z- RSingle Core Zero Halogen insulated Cable356 2 41 YSingle Core & Earth PVC Cable386242 YTwo Core & Earth PVC Cable386243 YThree Core & Earth PVC Cable386 2 41 BSingle Core & Earth Zero Halogen Cable406242 BTwo Core & Earth Zero Halogen Cable406243 BThree Core & Earth Zero Halogen Cable406181 YSingle Core PVC insulated And sheathed Cable43 PVC AND ZERO HALOGEN FLEXIBLE CABLES218-Y/H03 VVH-FFlexible PVC Light Duty Cable46219 -Y/ H 03V V H2- FFlexible PVC Light Duty Cable46209-Y, H03V2V2-F.

3 03V2V2-F* Heat Resistant PVC Flexible Cable49318-Y/H05VV-FFlexible PVC Ordinary Duty Cable51 Table of Contents5 Table of ContentsC a b le Ty p eDescription Page319-Y/H05 VVH2-F, 05 VVH2-F* Flexible PVC Cable51309-Y, H05V2V2-F, 05V2V2-F*Heat Resisting PVC Flexible Cable55318-AArctic Grade PVC flexible Cable58318-B / H05Z1Z1-FPVC and Zero Halogen Flexible Cables61 RUBBER FLEXIBLE CABLES318-TQ / H05BN4-FHeat Resisting Rubber Flexible Cable65638*P/H07RN-FRubber Flexible Trailing Cable67638*TQ/H07BN4-FHeat Resisting Rubber Trailing Cable710361 TQWelding Cable74H01N2-DHarmonised Welding cable76 Coil Lead 4 CCoil Lead Type 4C Cable78 ARMOURED POWER CABLES694-X XLPEA rmoured pvc sheathed Cable81694-LH XLPEA rmoured Zero Halogen sheathed Cable88 unarmoured POWER CABLE6181X YSingle Core xlpe insulated , pvc sheathed Cable1036181X BSingle Core Zero Halogen insulated And sheathed Cable106 NYYXLPE / PVC unarmoured Cable108 SERVICE CABLESH ybralStraight Concentric Cable115 Split Con PVCS plit Concentric PVC Cables117 Split Con xlpe Split Concentric xlpe Cable11966 Fire Performance Cables7 FLAME-X 950 SERIES 1(FLAME-X 950 Single) 600/1000 VBS 8573, Single core non- sheathed fire resistant cable having low emission of smoke and corrosive gases when affected by fireCHARACTERISTICSCONSTRUCTIONC onductors:Circular or compacted circular, stranded, annealed copper conductor, class 2 acc.

4 To BS EN 60228 Primary insulation:Fire resistant mica tape with a glass cloth Insulation:Special thermosetting LSOH compound of EI5 type acc. to BS EN 50363-5 Core identification:Green/yellow, blue, black, brown, grey, red, colours are available on special conductor operating temperature:+90 CLowest installation temperature:-5 CMaximum short-circuit conductor temperature:+25 0 CMinimum bending radius:6 D D overall diameter of the cableUMAX +90 CStandard length cable packing:100 m in coils or on spools, or 500 m on drums. Other forms of packing and delivery are available on use in fixed installations, where cable is protected by conduit or trunking. Fire resistant Cables intended to provide circuit integrity in case of performanceFire resistance:IEC 60331-21BS 63871)Circuit integrity - tested 90 min. at 950 CCategory C resistance to fire: 3 h at 950 CCategory W resistance to fire with water: 15 min at 650 C plus 15 min with water sprayCategory Z resistance to fire with mechanical shock: 15 min at 950 CFlame propagation:BS EN 60332-1-2 Smoke density:BS EN 61034-2 Corrosive and acid gases emission: BS EN 60754-12) HCl content < EN 60754-22) pH & conductivity 10 Smm-11) Category C, W, Z for Cables up to and including 95 mm2.

5 Category C for Cables above and including 120 mm2. 2) BS EN 60754-1 & BS EN 60754-2 standards replace BS EN 50267-2-1 LPCB1,5 mm2 to 500 mm2 single-coreApprovalsTechnical and Electrical CharacteristicNominal cross-sectional area of conductorRadial thickness of insulationApproximate overall diameterApproximate net weightMaximum resistance of conductor at temperature 20 Cmm2mmmmmm ..1 8 .1 09420 .19 5 011710 .15 .12 49 Nominal cross-sectional area of conductorRadial thickness of insulationApproximate overall diameterApproximate net weightMaximum resistance of conductor at temperature 20 Cmm2mmmmmm Ratings and Voltage DropNominal cross-sectional area of conductorShort circuit current ratings (1 sec)Current Rating* Two Cables , single phase or Rating* Three or four Cables , three phase Drop** Two Cables Drop** Two Cables , single phase Drop** Three or four Cables , three phase /mmV/A /mmV/A 97. 0 .19 .15 .12 * Installation reference method 3 (enclosed in conduit on a wall or in trunking etc.

6 ,) as per BS 7671, Appendix 4, Conductor operating temperature 90 C, Ambient temperature 30 C** Installation reference methods 3 and 4 (enclosed in conduit, etc., in or on a wall) as per BS 7671, Appendix 4, Conductor operating temperature 90 C, Ambient temperature 30 C10 Correction Factors for Ambient TemperatureCorrection Factors for GroupsAmbient Temperature, C25303540455055606570758085 Correction . of Circuits234567891012141618 Correction . the information in this document including tables and diagrams is given in good faith and believed to be correct at the time od publication. The information does not constitute a warranty nor representation for which TELE-FONIKA Kable assumes legal responsibility. TELE-FONIKA Kable reserves rights to introduce changes to the document at any time11 CONSTRUCTIONI nstallations emergency lighting and evacuation systems, fire and smoke detection systems, air-conditioning and alarm systems, automatic elevator doors, computer control rooms, offshore and marine emergency systems, emergency evacuation :Plain annealed copper solid class 1 (for 1 - mm2) and stranded class 2 ( for 4 mm2) acc.

7 To BS EN 60228 Uninsulated circuit protective conductor:Tinned annealed copper of the same nominal cross-sectional area and of the same class as the insulated conductorsDrain wire:Tinned annealed copper Wires class 2 acc. to BS EN 60228 ( for Cables with 7, 12, 19 cores)Insulation:Special cross-linked heat resistant compound type EI2 acc. to BS EN 50363-1 Optional binder:Non hygroscopic halogen free tapeScreen:Aluminium/polyester laminated tape and uninsulated circuit protective conductor or drain wireOuter sheath:Thermoplastic zero halogen low smoke compound type LTS 3 acc. to BS of sheath:Red or white (other colours are permissible when agreed with the manufacturer)Core identification:2 core + ECC: brown, blue3 core + ECC: brown, black, grey4 core + ECC: blue, brown, black, grey7, 12, 19 core + Drain wire: numbering or for identification by colour: in each layer: brown (starting core), black (reference core)MAX +7 0 CUAPPLICATIONSS tandard length cable packing:500 or 1,000 m on drums.

8 Other forms of packing and delivery are available on 950 SERIES 2(Flame-X 950 Standard) 300/500 VBS 7629-1, BS 6387, BS 5839-1 Fire resistant screened Cables having low emission of smoke and corrosive gases when affected by fire12 Maximum conductor operating temperature: +7 0 CMinimum operating temperature (for fixed application) after installation without movement:-40 CLowest installation temperature:0 CMaximum short-circuit conductor temperature:+25 0 CMinimum bending radius: 6 D; (D - overall cable diameter)CHARACTERISTICSR esistance to fire:BS 6387 Category C resistance to fire: 3 h at 950 C (IEC 60331) Category W resistance to fire with water: 15 min at 650 C plus 15 min with water spray Category Z resistance to fire with mechanical shock: 15 min at 950 CBS EN 50200 Class PH30 (resistance to fire. with mechanical shock and with water: 30 min)BS 5839-1:2002 Clause PH 30 Standard fire resistant cableFlame propagation:BS EN 60332-1-2 (IEC 60332-1-2) and BS EN 50266-2-2 (IEC 60332-3-22) Smoke density:BS EN 61034-2 (IEC 61034-2)Gases evolved during combustion:BS EN 50267-2-1 (IEC 61034-2): < acid gasBS EN 50267-2-2 (IEC 60754-2): pH ; conductivity 10 Smm-1 Fire performanceLPCB 1,0 , , 4 mm2 2-core, 3-core, 4-core, , , mm2 7-core, 12-core, mm2 mm2 2-core, , , 4 mm2 2-core, 3-core, 4-core, , mm2 7-core, 12-core, mm2 19-coreApprovals13 Technical and Electrical CharacteristicNumber and cross-sectional areaof conductorConductor classNominal cross-sectional area of protective conductorECCA pproximate overall diameterApproximate net weightof cablesMaximum conductor resistance at temperature 20 CMaximum ECC conductor resistance at 20 Cn mm2mm2mmkg/km /km /km2 1 RE + 8.

9 RE + 88612 . RM + ECC* . RE + 417. 5 62 RM + ECC* 417. 5 62 4 RM + 6 RM + ECC* .113 1 RE + ECC**117. 3811 8 . RE + . RE + 417. 5 63 4 RM + ECC2411. 1 RE + ECC** 8 . RE + . RM + ECC* . RE + 52057. 417. 5 64 4 RM + 1 RE** 8 .. 1 RE** 8 .. 1 RE* 8 . 8 .149612 . * based on norm. without certificate ** without standards14 Ambient air temperature: 30 C. Conductor operating temperature: 70 as specified in Appendix 4 of BS 7671 IEE Wiring RegulationsCurrent Ratings and Voltage DropNominal area of conductor1 two core cable * single phase or three-core or 1 four-core cable *. three-phase area of conductor1 two core cable * single phase or three-core or 1 four-core cable *. three-phase ratingVolts drop per ampere par metreCurrent ratingVolts drop per ampere par metreCurrent ratingVolts drop per ampere par metreCurrent ratingVolts drop per ampere par metremm2 AmV/mAmV/mmm2 AmV/ factors for ambient temperatureAll the information in this document including tables and diagrams is given in good faith and believed to be correct at the time od publication.

10 The information does not constitute a warranty nor representation for which TELE-FONIKA Kable assumes legal responsibility. TELE-FONIKA Kable reserves rights to introduce changes to the document at any timeReference Method 1(clipped direct )Reference Method 3(enclosed in conduit on a wall or ceiling, or in trunking)Ambient temperature, C253035404550 Rating :Plain annealed copper solid class 1 (for 1 - mm2)and stranded class 2 (for 4 mm2) acc. to BS EN 60228 and special requestPrimary insulation:Fire resistant mica tape with a glass clothInsulation:Special cross-linked heat resistant compound type EI2 acc. to BS EN 50363-1 Screen:Helically applied aluminium / polyester tape and uninsulated circuit protective conductorUninsulated circuit protective conductor:Tinned annealed copper conductor of the same nominal cross-sectional area and of the same class as the insulated conductorsOuter sheath:Thermoplastic zero halogen low smoke compound type LTS 3 acc. to BS of sheath:Red or white.


Related search queries