Transcription of CAD and Image Standards for Construction Documentation
1 Last updated on 9/15/09 HARVARD UNIVERSITY UNIVERSITY PLANNING OFFICE CAD and Image Standards for Construction Documentation Holyoke Center Suite 573 1350 Massachusetts Avenue Cambridge, MA 02138 t e: Last updated on 9/15/09 #cadstandards p. 2 i. INTRODUCTION .. 3 1. CAD DRAWING PRODUCTION .. 4 1. 1 FILE FORMAT and SETUP .. 4 Electronic File Format .. 4 scale , Unit, and Tolerances .. 4 Fonts & Text Styles .. 4 Blocks .. 4 Title 4 Policy on External Reference Files (XREFs).
2 5 Policy on Image Files (JPGs, BMPs, PNGs) .. 5 Policy on model Space and Paper Layout Space ..5 Use Disclaimer .. 5 6 Layer Name 6 General Rules about Names and Uses .. 7 Standard Layer Listing .. 8 Attributes (Colors, Linetypes, Pens).. 14 1. 3 POLICY on CAD FILE TRANSLATION .. 15 Error-free AutoCAD Drawing Translation Testing Recommended .. 15 2. Image FILE PRODUCTION .. 16 OVERVIEW .. 16 Image PRODUCTION .. 16 Content .. 16 Electronic File Format .. 16 16 Bit Depth .. 16 TIF CREATION AND CONVERSION.
3 17 AutoCAD TIF Creation .. 17 Conversion to TIF from Other File 17 3. SHEET IDENTIFICATION AND DELIVERY .. 18 SHEET AND FILE NAMING CONVENTION .. 18 Naming Construction drawings .. 18 Sheet 18 APPENDICES .. 19 A. ELECTRONIC FILE QUALITY ASSURANCE 20 B. ELECTRONIC FILE INDEX .. 21 Last updated on 9/15/09 #cadstandards p. 3 i. INTRODUCTION This document outlines how to produce and deliver CAD drawings and raster images of as-built Construction drawings . For purposes of this document Image files refer to the TIF format.
4 The University Planning Office revised this standard in January 2009. Prior versions were published in 2006, 2002, 1999, 1996 and 1994. The revisions in this edition focus on file naming conventions and Image policies. The purpose of this document is to serve as a tight specification for producing and delivering CAD drawings and Image files that document as-built conditions for Construction projects. The guidelines are intended to ensure consistency of materials and to maximize both short and long term usability of Construction Documentation .
5 Before a capital project can be closed out and final payment from Harvard University rendered, all specified materials must be submitted to the appropriate Harvard project manager or representative in accordance with production Standards and special instructions described throughout this document. See also the publication Capital Projects Closeout Construction Documentation Requirements - Guidelines for Architects, Contractors, and Project Managers (available at ) for the list of closeout requirements.
6 A signed copy of the Electronic File Quality Assurance Checklist (Template 3) in the Closeout Requirements must also be submitted with CAD drawings and Image files being delivered during the closeout phase of Construction projects. In signing and submitting an Electronic Quality Assurance Checklist, the vendor (architect, engineer, contractor, etc.) is assuring that all materials adhere to the Standards and guidelines set forth in this document. This standard complies with the layering standard found in the AIA CAD Layer Guidelines found in the United States National CAD Standard Version 4.
7 The file naming convention is based on the sheet identification format and also complies with the National CAD Standard. The layering standard outlined herein was derived from the 1997 American Institute of Architects CAD Layer Guidelines. For additional detail beyond what is outlined herein, please refer to the National CAD Standard for guidance. A copy of the current National CAD Standard may be obtained from Standards for CAD drawings documenting space, for import in a space management system, are in a separate document Harvard University Space Documentation CAD Standard.
8 Please direct any questions or comments about this document to the address below. Harvard University Planning Office 573 Holyoke Center 1350 Massachusetts Avenue Cambridge, MA 02138. tel: 617-496-4434 email: and Last updated on 9/15/09 #cadstandards p. 4 1. CAD DRAWING PRODUCTION 1. 1 FILE FORMAT and SETUP Electronic File Format As-built Construction project drawings must be submitted to Harvard University in full compliance with the most recent or prior version of AutoCAD software at the time of submission (file extension =.)
9 DWG). scale , Unit, and Tolerances All CAD drawing models should be drafted at full scale in architectural units, such that one drawing unit equals one inch. Tolerances for Construction drawings are implicit within professional service contracts. Fonts & Text Styles Text styles and fonts may vary, but the use of font for most applications is desirable. Special fonts which are not packaged with AutoCAD are not allowed. Dimensions, labels and notes, should be not less than 1/8 height on printed drawings Blocks Harvard is currently not imposing the use of any particular block definitions or block libraries.
10 However, Harvard requires that the following general rules be employed when handling block entities: 1. All entities within a block must be created on layer 0. 2. Drawing entities translated into blocks from non-AutoCAD systems must revert to layer 0 when exploded. 3. File translation from other systems which result in wall blocks within the .DWG file are unacceptable. Title Blocks Each CAD file submitted to Harvard should have only one title block. If using paper space, the title block should be placed with its lower left hand corner point inserted at a coordinate location of (0,0,0).