CADWELD WELDED ELECTRICAL CONNECTIONS

CADWELD WELDED . ELECTRICAL CONNECTIONS . QUICK REFERENCE PRODUCT GUIDE. XXX of Contents Table Cable to Cable TA - Horizontal 3. PT - Parallel Horizontal 3. SS - Horizontal 3. PC - Parallel 3. XB - Lapped Horizontal 4. XA - Horizontal 4. Cable to Bus or Lug LA - Cable to 4. LJ - Cable to Bus 4. Cable to Ground Rod GR - Cable to Ground 5. GT - Through Cable to Top of Ground 5. GY - Through Cable to Side of Ground 5. NC - Through Cable / Tap to Ground 5. CADWELD ONE 6. CADWELD PLUS ONE 6. Cable to Rebar RR - Cable to 7. RD - Cable to 7. RJ - Cable to 7. Cable to Steel Surface VS - Cable to Vertical 8. VB - Cable to Vertical 8. VF - Cable to Vertical 8. HA - Cable to Horizontal 8. HS - Cable to Horizontal 8. Materials, Tools & 9. CADWELD WARNING. Pentair products shall be installed and used only as indicated in Pentair's product instruction sheets and training materials. Instruction sheets are available at and from your Pentair customer service representative. Improper installation, misuse, misapplication or other failure to completely follow Pentair's instructions and warnings may cause product malfunction, property damage, serious bodily injury and/or death, and void your warranty.

7 xxx wwwericoentairco cable to rebar a c h m includes frame with handle requires l160 handle clamp includes toggle frame with handle 2 cable cadweld cable

Tags:

  Electrical, Connection, Welded, Cadweld, Cadweld welded electrical connections

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of CADWELD WELDED ELECTRICAL CONNECTIONS

1 CADWELD WELDED . ELECTRICAL CONNECTIONS . QUICK REFERENCE PRODUCT GUIDE. XXX of Contents Table Cable to Cable TA - Horizontal 3. PT - Parallel Horizontal 3. SS - Horizontal 3. PC - Parallel 3. XB - Lapped Horizontal 4. XA - Horizontal 4. Cable to Bus or Lug LA - Cable to 4. LJ - Cable to Bus 4. Cable to Ground Rod GR - Cable to Ground 5. GT - Through Cable to Top of Ground 5. GY - Through Cable to Side of Ground 5. NC - Through Cable / Tap to Ground 5. CADWELD ONE 6. CADWELD PLUS ONE 6. Cable to Rebar RR - Cable to 7. RD - Cable to 7. RJ - Cable to 7. Cable to Steel Surface VS - Cable to Vertical 8. VB - Cable to Vertical 8. VF - Cable to Vertical 8. HA - Cable to Horizontal 8. HS - Cable to Horizontal 8. Materials, Tools & 9. CADWELD WARNING. Pentair products shall be installed and used only as indicated in Pentair's product instruction sheets and training materials. Instruction sheets are available at and from your Pentair customer service representative. Improper installation, misuse, misapplication or other failure to completely follow Pentair's instructions and warnings may cause product malfunction, property damage, serious bodily injury and/or death, and void your warranty.

2 2 XXX to Cable Cable TA - Horizontal Tee PT - Parallel Horizontal Tee CONDUCTOR WELDING CADWELD CONDUCTOR WELDING CADWELD . MOLD MATERIAL PLUS WELDING MOLD MATERIAL PLUS WELDING. Run Tap (QTY) P/N MATERIAL P/N Run Tap (QTY) P/N MATERIAL P/N. 4 6 TAC1L1H 32 32 PLUSF20 2 SOL 2 SOL PTC1T1T 65 65 PLUSF20. 4 TAC1L1L 32 32 PLUSF20 2 2 PTC1V1V 65 65 PLUSF20. 2 SOL 2 SOL TAC1T1T 45 45 PLUSF20 1/0 PTC2C2C 90 90 PLUSF20. 1/0. 4 TAC1V1L 45 45 PLUSF20 4/0 PTC2C2Q 150 150 PLUSF20. 2 2 SOL PTC2G1T 90 90 PLUSF20. 2 TAC1V1V 45 45 PLUSF20. 4 TAC2C1L 45 45 PLUSF20 2 PTC2G1V 90 90 PLUSF20. 2/0. 1/0 2 TAC2C1V 45 45 PLUSF20 1/0 PTC2G2C 115 115 PLUSF20. 1/0 TAC2C2C 90 90 PLUSF20 2/0 PTC2G2G 115 115 PLUSF20. 4/0 TAC2C2Q 115 115 PLUSF20 4/0 PTC2G2Q 150 150 PLUSF20. 4 TAC2G1L 45 45 PLUSF20 1/0 PTC2L2C 115 90 PLUSF20. 3/0. 2 TAC2G1V 45 45 PLUSF20 3/0 PTC2L2L 150 150 PLUSF20. 2/0 1/0 PTC2Q2C 150 150 PLUSF20. 1/0 TAC2G2C 90 90 PLUSF20. 2/0 TAC2G2G 90 90 PLUSF20 4/0 2/0 PTC2Q2G 150 150 PLUSF20. 4/0 TAC2G2Q 115 115 PLUSF20 3/0 PTC2Q2L 200 200 PLUSF20.

3 2 TAC2L1V 45 45 PLUSF20 4/0 PTC2Q2Q 200 200 PLUSF20. 1/0 TAC2L2C 90 90 PLUSF20. 3/0. 2/0 TAC2L2G 90 90 PLUSF20. 3/0 TAC2L2L 115 115 PLUSF20. 4/0 SOL 4/0 SOL TAC2P2P 150 150 PLUSF20. 4 TAC2Q1L 90 90 PLUSF20. 2 TAC2Q1V 90 90 PLUSF20. 1/0 TAC2Q2C 90 90 PLUSF20. 4/0. 2/0 TAC2Q2G 90 90 PLUSF20. 3/0 TAC2Q2L 115 115 PLUSF20. 4/0 TAC2Q2Q 150 150 PLUSF20. 350 TAC2Q3A 150 150 PLUSF20 PC - Parallel Tap 500 TAC2Q3Q 150 150 PLUSF20. 2/0 TAC2V2G 90 90 PLUSF20 CONDUCTOR WELDING CADWELD . 250 4/0 TAC2V2Q 150 150 PLUSF20 MOLD MATERIAL PLUS WELDING. 250 TAC2V2V 150 150 PLUSF20 Run Tap (QTY) P/N MATERIAL P/N. 4/0 TAC3D2Q 150 150 PLUSF20. 350 6 SOL 6 SOL PCC1G1G 25 25 PLUSF20. 350 TAC3D3D 200 200 PLUSF20. 6 6 PCC1H1H 25 25 PLUSF20. 2 SOL 2 SOL PCC1T1T 65 65 PLUSF20. 2 PCC1V1V 65 65 PLUSF20. 2. 6 PCC1T1G 32 32 PLUSF20. 1/0 6 PCC2C1H 45 45 PLUSF20. 2/0 6 SOL PCC2G1G 65 65 PLUSF20. 6 PCC2G1H 65 65 PLUSF20. 2 PCC2G1V 90 90 PLUSF20. 3/0 6 PCC2L1H 90 90 PLUSF20. 6 SOL PCC2Q1G 90 90 PLUSF20. 6 PCC2Q1H 90 90 PLUSF20.

4 4/0 2 SOL PCC2Q1T 115 115 PLUSF20. SS - Horizontal Splice 2. 4. PCC2Q1V. PCC2Q1L. 115. 90. 115 PLUSF20. 90 PLUSF20. 4/0 PCC2Q2Q 150 150 PLUSF20. WELDING CADWELD . CONDUCTOR MOLD MATERIAL PLUS WELDING. (QTY) P/N MATERIAL P/N. HANDLE CLAMP / FRAME (see page 10). 4 SST1L 25 25 PLUSF20. 2 SOL SST1T 32 32 PLUSF20 PRICE KEY NOTES. 2 SST1V 32 32 PLUSF20. 1/0 SSC2C 45 45 PLUSF20 C REQUIRES L160 HANDLE CLAMP. 2/0 SSC2G 65 65 PLUSF20 P INCLUDES B399C FRAME, T320 IGNITOR. 3/0 SSC2L 90 90 PLUSF20 Q REQUIRES L160 HANDLE CLAMP. 4/0 SSC2Q 90 90 PLUSF20 T INCLUDES B399A FRAME, T320 IGNITOR. 250 SSC2V 115 115 PLUSF20 Z REQUIRES L159 HANDLE CLAMP. 3. XXX to Cable Cable to Bus / Lug Cable XB - Lapped Horizontal Splice XA - Horizontal Splice CONDUCTOR WELDING CADWELD CONDUCTOR WELDING CADWELD . MOLD MATERIAL PLUS WELDING MOLD MATERIAL PLUS WELDING. Run Tap (QTY) P/N MATERIAL P/N Run Tap (QTY) P/N MATERIAL P/N. 6 SOL 6 SOL XBP1G1G 32 32 PLUSF20 4 4 XAC1L1L 45 65 PLUSF20. 4 4 XBC1L1L 65 65 PLUSF20 2 2 XAC1V1V 65 65 PLUSF20.

5 2 2 XBC1V1V 90 90 PLUSF20 1/0 1/0 XAC2C2C 90 90 PLUSF20. 1/0 1/0 XBQ2C2C 150 150 PLUSF20 2/0 2/0 XAC2G2G 115 115 PLUSF20. 2/0 2/0 XBQ2G2G 200 200 PLUSF20 3/0 3/0 XAC2L2L 150 150 PLUSF20. 2/0 XBQ2Q2G 200 200 PLUSF20 2/0 XAC2Q2G 150 150 PLUSF20. 4/0 4/0. 4/0 XBQ2Q2Q 250 250 PLUSF20 4/0 XAC2Q2Q 200 200 PLUSF20. 250 250 XBQ2V2V (2) 150 300 PLUSF20 4/0 XAC2V2Q 200 200 PLUSF20. 250. 350 350 XBZ3D3D 500 500 PLUSF20 250 XAC2V2V 200 200 PLUSF20. 500 500 XBZ3Q3Q (3) 250 750 PLUSF20 350 350 XAC3D3D 250 250 PLUSF20. 4/0 XAD3Q2Q (2) 150 300 PLUSF20. 500. 500 XAD3Q3Q 500 500 PLUSF20. LA - Cable to Lug LJ - C. able to Bus Bar BUS OR CABLE WELDING CADWELD BUS OR CABLE WELDING CADWELD . MOLD MATERIAL PLUS WELDING LUG SIZE SIZE MOLD MATERIAL PLUS WELDING. LUG SIZE SIZE (QTY) P/N MATERIAL P/N. (QTY) P/N MATERIAL P/N. 6 LJCEG1H 65 65 PLUSF20. 2 SOL LAC1 TCE 45 45 PLUSF20. 2 SOL LJCEG1T 65 65 PLUSF20. 1/8 x 1 2 LAC1 VCE 45 45 PLUSF20. 1/4 x 2 LJCEG1V 65 65 PLUSF20. Lug / Bus 1/0 LAC2 CCE 45 45 PLUSF20.

6 1-1/2 1/0 LJCEG2C 90 90 PLUSF20. 2/0 LAC2 GCE 65 65 PLUSF20. & Wider Lug/ 2/0 LJCEG2G 90 90 PLUSF20. 3/0 LAC2 LCE 65 65 PLUSF20. Bus 3/0 LJCEG2L 90 90 PLUSF20. 4/0 LAC2 QCE 65 65 PLUSF20. 4/0 LJCEG2Q 90 90 PLUSF20. 1/0 LAC2 CEE 65 65 PLUSF20. 500 LJCEG3Q 200 200 PLUSF20. 2/0 LAC2 GEE 65 65 PLUSF20. 1/4 x 1 4/0 SOL LAC2 PEE 90 90 PLUSF20. Lug / Bus 4/0 LAC2 QEE 90 90 PLUSF20. 300 LAC3 AEE 90 90 PLUSF20. 350 LAC3 DEE 115 115 PLUSF20. 4/0 LAC2 QEG 90 90 PLUSF20. 1/4 x 1-1/2 250 LAC2 VEG 90 90 PLUSF20. Lug/Bus 350 LAC3 DEG 115 115 PLUSF20. 500 LAC3 QEG 200 200 PLUSF20. HANDLE CLAMP / FRAME (see page 10). PRICE KEY NOTES. C REQUIRES L160 HANDLE CLAMP. P INCLUDES B399C FRAME, T320 IGNITOR. Q REQUIRES L160 HANDLE CLAMP. T INCLUDES B399A FRAME, T320 IGNITOR. Z REQUIRES L159 HANDLE CLAMP. 4 XXX to Ground Rod Cable GR - Cable to Ground Rod GT - Through Cable to Top of Ground Bar GROUND CABLE WELDING CADWELD . ROD SIZE SIZE MOLD MATERIAL PLUS WELDING GROUND CABLE WELDING CADWELD .

7 (QTY) P/N MATERIAL P/N ROD SIZE SIZE MOLD MATERIAL PLUS WELDING. (QTY) P/N MATERIAL P/N. 6 SOL GRT161G 32 32 PLUSF20. 6 GRT161H 32 32 PLUSF20 6 GTT161G 32 32 PLUSF20. 5/8 4 SOL GRT161K 32 32 PLUSF20 5/8 4 GTT161L 32 32 PLUSF20. Copper- 4 GRT161L 32 32 PLUSF20 Copper- 2 SOL GTC161T 90 90 PLUSF20. bonded 2 SOL GRC161T 65 65 PLUSF20 bonded 2 GTC161V 90 90 PLUSF20. Sectional 2 GRC161V 65 65 PLUSF20 Sectional 1/0 GTC162C 90 90 PLUSF20. (threaded) 1/0 GRC162C 90 90 PLUSF20 (threaded) 2/0 GTC162G 115 115 PLUSF20. or Plain 2/0 GRC162G 90 90 PLUSF20 or Plain 3/0 GTC162L 115 115 PLUSF20. 3/0 GRC162L 90 90 PLUSF20 4/0 GTC162Q 115 115 PLUSF20. 4/0 GRC162Q 90 90 PLUSF20 250 GTC162V 150 150 PLUSF20. 250 GRC162V 90 90 PLUSF20 500 GTC163Q 250 250 PLUSF20. 500 GRC163Q 115 115 PLUSF20 6 SOL GTP181G 45 45 PLUSF20. 6 SOL GRT181G 32 32 PLUSF20 3/4 6 GTP181H 45 45 PLUSF20. 6 GRT181H 32 32 PLUSF20 Copper- 2 SOL GTC181T 90 90 PLUSF20. 4 SOL GRP181K 45 45 PLUSF20 bonded 2 GTC181V 90 90 PLUSF20.

8 3/4 4 GRP181L 45 45 PLUSF20 Sectional 1/0 GTC182C 115 115 PLUSF20. Copper- 2 SOL GRC181T 90 90 PLUSF20 (threaded) 2/0 GTC182G 115 115 PLUSF20. bonded 2 GRC181V 90 90 PLUSF20 or Plain 3/0 GTC182L 115 115 PLUSF20. Sectional 1/0 GRC182C 90 90 PLUSF20 4/0 GTC182Q 115 115 PLUSF20. (threaded) 2/0 GRC182G 90 90 PLUSF20 250 GTC182V 150 150 PLUSF20. or Plain 3/0 GRC182L 90 90 PLUSF20 500 GTC183Q 250 200 PLUSF20. 4/0 GRC182Q 90 90 PLUSF20. 250 GRC182V 90 90 PLUSF20. 500 GRC183Q 150 150 PLUSF20. NC - Through Cable / Tap to Ground Rod GY - Through Cable to Side of GROUND CABLE. MOLD. WELDING CADWELD . MATERIAL PLUS WELDING. ROD SIZE SIZE. Ground Bar (QTY) P/N MATERIAL P/N. 5/8 2 SOL NCR161T 115 115 PLUSF20. GROUND CABLE WELDING CADWELD Copper- 2 NCR161V 115 115 PLUSF20. ROD SIZE SIZE MOLD MATERIAL PLUS WELDING bonded 1/0 NCR162C 150 150 PLUSF20. (QTY) P/N MATERIAL P/N Sectional 2/0 NCR162G 200 200 PLUSF20. (threaded). 2 SOL GYR161T 90 90 PLUSF20 3/0 NCR162L 250 250 PLUSF20. or Plain 5/8 2 GYR161V 90 90 PLUSF20 4/0 NCR162Q 250 250 PLUSF20.

9 Copper- 1/0 GYR162C 115 115 PLUSF20 3/4 6 NCR181H 90 90 PLUSF20. bonded 2/0 GYR162G 115 115 PLUSF20 Copper- 2 SOL NCR181T 115 115 PLUSF20. Sectional 3/0 GYR162L 150 150 PLUSF20 bonded 2 NCR181V 115 115 PLUSF20. (threaded) 4/0 GYR162Q 150 150 PLUSF20 Sectional 1/0 NCR182C 150 150 PLUSF20. or Plain 250 GYR162V 150 150 PLUSF20 (threaded) 2/0 NCR182G 200 200 PLUSF20. or Plain 3/0 NCR182L 250 250 PLUSF20. 350 GYR163D 250 250 PLUSF20. 500 GYF163Q 400 400 PLUSF20 4/0 NCR182Q 250 250 PLUSF20. 2 SOL GYR181T 90 90 PLUSF20. 3/4 2 GYR181V 90 90 PLUSF20. Copper- 1/0 GYR182C 115 115 PLUSF20. bonded 2/0 GYR182G 115 115 PLUSF20 HANDLE CLAMP / FRAME (see page 10). Sectional 3/0 GYR182L 150 150 PLUSF20. (threaded) 4/0 GYR182Q 150 150 PLUSF20 C REQUIRES L160 HANDLE CLAMP. or Plain 250 GYR182V 200 200 PLUSF20 P INCLUDES B399C FRAME, T320 IGNITOR. 350 GYR283D 300 300 PLUSF20 T INCLUDES B399A FRAME, T320 IGNITOR. 500 GYF183Q 500 500 PLUSF20 F REQUIRES L159 HANDLE CLAMP. 5. XXX to Ground Rod Cable CADWELD ONE SHOTs and CADWELD PLUS ONE SHOTs produce permanent exothermic CONNECTIONS to ground rods that will not loosen, corrode or increase in resistance for the life of the installation.

10 A convenient, single-use ceramic mold eliminates the need for a mold and handle clamps and/or frame. CADWELD ONE SHOT. GROUND CONCENTRIC CONDUCTOR CADWELD ONE SHOT. ROD. SOLID STRANDED Type GR Type GT Type NT Type NX. 6, 8 8 GR1141G GT1141G NT1141G NX1141G. 1/2 3, 4 4, 6 GR1141L GT1141L NT1141L NX1141L. 1, 2 2, 3 GR1141V GT1141V NT1141V. 6, 8 8 GR1161G GT1161G NT1161G NX1161G. 3, 4 4, 6 GR1161L GT1161L NT1161L NX1161L. 1, 2 2, 3 GR1161V GT1161V NT1161V NX1161V. 5/8 . 2/0, 1/0 1/0, 1 GR1162C GT1162C. 2/0 GR1162G GT1162G. 4/0 GR1162Q. 6, 8 8 GR1181G GT1181G NT1181G NX1181G. 3, 4 4, 6 GR1181L GT1181L NT1181L NX1181L. 1, 2 2, 3 GR1181V GT1181V NT1181V NX1181V. 3/4 . 2/0, 1/0 1/0, 1 GR1182C GT1182C. 2/0 GR1182G GT1182G. 4/0 GR1182Q. Requires flint ignitor p/n T320 (sold separately). CADWELD PLUS ONE SHOT. GROUND CONCENTRIC CONDUCTOR CADWELD PLUS ONE SHOT. ROD. SOLID STRANDED Type GR Type GT Type NT Type NX. 6, 8 8 GR1141 GPLUS GT1141 GPLUS NT1141 GPLUS NX1141 GPLUS. 1/2 3, 4 4, 6 GR1141 LPLUS GT1141 LPLUS NT1141 LPLUS NX1141 LPLUS.