Example: quiz answers

CAER - CCMPA

seismic DESIGN GUIDE FOR MASONRY BUILDINGS. CHAPTER 1. Donald Anderson Svetlana Brzev Canadian Concrete Masonry Producers Association April 2009. DISCLAIMER. While the authors have tried to be as accurate as possible, they cannot be held responsible for the designs of others that might be based on the material presented in this document. The material included in this document is intended for the use of design professionals who are competent to evaluate the significance and limitations of its contents and recommendations and able to accept responsibility for its application. The authors, and the Canadian Concrete Masonry Producers Association, disclaim any and all responsibility for the applications of the stated principles and for the accuracy of any of the material included in the document.

i Contents Summary Chapter 1 NBCC 2005 Seismic Provisions Objective: to provide background on seismic response of structures and seismic analysis methods and explain key NBCC 2005 seismic provisions of relevance for masonry design

Tags:

  Seismic, Care, Nbcc

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of CAER - CCMPA

1 seismic DESIGN GUIDE FOR MASONRY BUILDINGS. CHAPTER 1. Donald Anderson Svetlana Brzev Canadian Concrete Masonry Producers Association April 2009. DISCLAIMER. While the authors have tried to be as accurate as possible, they cannot be held responsible for the designs of others that might be based on the material presented in this document. The material included in this document is intended for the use of design professionals who are competent to evaluate the significance and limitations of its contents and recommendations and able to accept responsibility for its application. The authors, and the Canadian Concrete Masonry Producers Association, disclaim any and all responsibility for the applications of the stated principles and for the accuracy of any of the material included in the document.

2 AUTHORS. Don Anderson, , Svetlana Brzev, , Department of Civil Engineering, Department of Civil Engineering University of British Columbia British Columbia Institute of Technology Vancouver, BC Burnaby, BC. TECHNICAL EDITORS. Gary Sturgeon, , Director of Technical Services, CCMPA . Bill McEwen, , LEED AP, Executive Director, Masonry Institute of BC. Dr. Mark Hagel, EIT, Technical Services Engineer, CCMPA . GRAPHIC DESIGN. Natalia Leposavic, COVER PAGE. Photo credit: Bill McEwen, Graphic design: Marjorie Greene, AICP. COPYRIGHT. Canadian Concrete Masonry Producers Association, 2009. Canadian Concrete Masonry Producers Association Box 54503, 1771 Avenue Road Toronto, ON M5M 4N5.

3 Tel: (416) 495-7497. Fax: (416) 495-8939. Email: Web site: The Canadian Concrete Masonry Producers Association ( CCMPA ) is a non-profit association whose mission is to support and advance the common interests of its members in the manufacture, marketing, research, and application of concrete masonry products and structures. It represents the interests of Region 6 of the National Concrete Masonry Association (NCMA). Contents Summary Chapter 1 nbcc 2005 seismic Provisions Objective: to provide background on seismic response of structures DETAILED. and seismic analysis methods and explain key nbcc 2005 seismic nbcc seismic .

4 Provisions of relevance for masonry design PROVISIONS. Chapter 2 seismic Design of Masonry Walls to CSA Objective: to provide background and commentary for CSA DETAILED. seismic design provisions related to reinforced concrete masonry walls, MASONRY. and discuss the revisions in CSA seismic design DESIGN. requirements with regard to the 1994 edition PROVISIONS. Chapter 3 Summary of Changes in nbcc 2005 and CSA seismic Design Requirements for Masonry Buildings Objective: to provide a summary of nbcc 2005 and CSA SUMMARY OF. changes with regard to previous editions ( nbcc 1995 and CSA nbcc AND.)

5 94) and to present the results of a design case study of a hypothetical low-rise masonry building to illustrate differences in seismic forces and CHANGES. masonry design requirements due to different site locations and different editions of nbcc and CSA Chapter 4 Design Examples Objective: to provide illustrative design examples of seismic load DESIGN. calculation and distribution of forces to members according to nbcc EXAMPLES. 2005, and the seismic design of loadbearing and nonloadbearing masonry elements according to CSA Appendix A Comparison of nbcc 1995 and nbcc 2005 seismic Provisions Appendix B Research Studies and Code Background Relevant to Masonry Design Appendix C Relevant Design Background Appendix D Design Aids Appendix E Notation i TABLE OF CONTENTS CHAPTER 1.

6 1 seismic DESIGN PROVISIONS OF THE NATIONAL BUILDING CODE OF CANADA. 2005 ..1-2. Introduction ..1-2. Background ..1-2. Design and Performance Objectives ..1-3. Response of Structures to Earthquakes ..1-4. Elastic Response ..1-4. Inelastic A Primer on Modal Dynamic Analysis Procedure ..1-10. seismic Analysis According to nbcc 2005 ..1-19. seismic Hazard ..1-19. Effect of Site Soil Methods of Analysis ..1-23. Base Shear Calculations- Equivalent Static Analysis Procedure ..1-24. Force Reduction Factors Rd and Ro ..1-27. Higher Mode Effects ( M v factor) ..1-28. Vertical Distribution of seismic Forces.

7 1-30. Overturning Moments ( J factor) ..1-31. Torsion ..1-32. Configuration Issues: Irregularities and Deflections and Drift Limits ..1-44. Dynamic Analysis Soil-Structure 4/1/2009 1-1. 1 seismic Design Provisions of the National Building Code of Canada 2005. Introduction This chapter provides a review of the seismic design provisions in the 2005 National Building Code of Canada ( nbcc 2005). Additionally, there is an introduction to the dynamic analysis of structures to assist in understanding the nbcc provisions. Since there are major changes to the seismic provisions reflected in nbcc 2005, some comparisons will be made to the previous edition of the building code, nbcc 1995, and this is covered in more detail in Appendix A.

8 In the past, building structures in many areas of Canada did not have to be designed for earthquakes. However, after the nbcc 2005 was issued and adopted by the Provinces, structures in some additional areas must now be designed for earthquakes, especially if the structure is an important or post-disaster building, or if it is located on a soft soil site. Since many engineers in these regions have not had experience in seismic design and now may have to include such design in their practice, this guideline has been prepared to explain the seismic provisions included in the nbcc 2005 and CSA , and to point out the recent changes in these two documents as they pertain to masonry design.

9 Background seismic design of masonry structures became an issue following the 1933 Long Beach, California earthquake in which school buildings suffered damage that would have been fatal to students had the earthquake occurred during school hours. At that time, a seismic lateral load equal to the product of a seismic coefficient and the structure weight had to be considered in those areas of California known to be seismically active. Strong motion instruments that could measure the peak ground acceleration or displacement were developed around that time, and in fact, the first strong motion accelerogram was recorded during the 1933 Long Beach earthquake.

10 However, in this era the most widely used strong ground motion acceleration record was measured at El Centro during the 1940 Imperial Valley earthquake in southern California. The 1940 El Centro record became famous and is still used by many researchers studying the effect of earthquakes on structures. With the availability of ground motion acceleration records (also known as acceleration time history records), it was possible to determine the response of simple structures modelled as single degree of freedom systems. After computers became available in the 1960s it was possible to develop more complex models for analyzing the response of larger structures.