A) Assembly Data (allowable loads, torque requirements and Factor of Safety used)B) Customised project name or detailEmail your connection requirement (contact details on next sheet)Example shown: GC001-1As part of its extensive Technical Support service Lindapter, the innovators of steelwork clamping fixings, can design a bespoke connection based on your specific requirements free of charge in three easy ) Your company nameD) Lindapter product requirementsE) Additional dimensions for precise fabricationLindapter s experienced Engineers will devise your bespoke solution132An Engineer will send you a design drawing, as below>>Each drawing includes.

sections of the national structural steelwork specification (nsss) for building construction 5th edition ce marking version. 5. if felt necessary, where excessive vibration may be a concern, it is acceptable for certain types …

Tags:

  Specification, National, Structural, Steelwork, National structural steelwork specification

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of can design a bespoke connection based on your …

1 A) Assembly Data (allowable loads, torque requirements and Factor of Safety used)B) Customised project name or detailEmail your connection requirement (contact details on next sheet)Example shown: GC001-1As part of its extensive Technical Support service Lindapter, the innovators of steelwork clamping fixings, can design a bespoke connection based on your specific requirements free of charge in three easy ) Your company nameD) Lindapter product requirementsE) Additional dimensions for precise fabricationLindapter s experienced Engineers will devise your bespoke solution132An Engineer will send you a design drawing, as below>>Each drawing includes.

2 connection DESIGNA vailable now fromATop BeamFlange Width = 203mmFlange Thickness = BeamFlange Width = 102mmFlange Thickness = 6mm 10 116 218 180 270 14 THRUDETAIL A SCALE 1 : x 70mm Long Setscrew, PropertyClass , with Class 8 Nut & Plain WasherLindapter B12L ClampLindapter A12M ClampLindapter P1S12 PackerLocation PlateFor combined loadings the current relevant nationalstandard should be taken into consideration Assembly Data:Static Tensile SWL = kNFactor of Safety :5 : 1 Static Slip Resistance SWL = kNFactor of Safety :5 : 1 Lindapter Fastener Tightening Torque =69 NmGC001-1 connection DetailsDWG.

3 TITLEGENERAL NOTES:NOT TO SCALEDO NOT SCALE THIS DRAWING AND THE COPYRIGHT THEREIN ARE THE OF LINDAPTER INTERNATIONAL. IT IS ISSUED ON THE CONDITION THAT IT MUST NOT BE USED, COPIED, DISTRIBUTED OR EXHIBITED WITHOUT WRITTEN PERMISSION AND CONSENT. THE DRAWING MUST ALSO NOT BE USED FOR ANY OTHER PURPOSE THAN WHICH IT IS IS THE RESPONSIBILITY OF THE ENGINEER TO PERFORM REASONABLE CHECKS ON THE SUPPORTING AND SUPPORTED MEMBERS. THAT IS LOCAL TO THE connection AND THE LINDAPTER COMPONENTS, BOTH FOR THE LOAD APPLIED AND THE CLAMPING FORCE GENERATED FROM THE TIGHTENING OF THE NECESSARY WORKMANSHIP FOR ITEMS SHOWN THIS DRAWING SHOULD COMPLY WITH THE RELEVANT SECTIONS OF THE national structural steelwork specification (NSSS) FOR BUILDING CONSTRUCTION 5TH EDITION CE MARKING FELT NECESSARY, WHERE EXCESSIVE VIBRATION MAY BE CONCERN, IT IS ACCEPTABLE FOR CERTAIN TYPES OF ANTI-VIBRATION LOCKING DEVICES SUCH AS, BUT NOT LIMITED TO, PROPRIETARY WASHERS AND NUTS TO BE USED WITH LINDAPTER COMPONENTS AND/OR ASSEMBLIES.

4 SPRING WASHERS OF ANY TYPE ARE NOT RECOMMENDED. IN THESE SITUATIONS IT IS IMPORTANT THAT THE MANUFACTURER'S INSTALLATION INSTRUCTIONS ARE FOLLOWED. NO GUARANTEES OR WARRANTIES ARE NOTES:PROJECTDIMENSIONS ARE IN : : BEND COATINGS TO BE SPECIFIED BY THE ENGINEER connection DESIGNA vailable now fromWhy choose Lindapter?Lindapter s experienced team of Engineers ensures an efficient specification process from start to finish, aiming to create a bespoke solution that delivers on cost and performance, ultimately saving you time and provides drawings in 2D and interactive 3D formats as well as CAD files that are suitable to import into all major software applications.

5 We can even customise the drawing by adding your project name so it s ready for plan checking immediately, thereby reducing design time. Simply provide the details listed on the right and Lindapter will do the rest!If you would like Lindapter to design your bespoke connection , please make sure to have the following:1. Member sizes to be used or flange width and thickness2. Loads to be resisted (eg. 10kN tension and 15kN slip)3. General arrangement sketch and/or verbal description*4. Project Name / Title (optional)5. Project Location (optional)*See Lindapter s catalogue for different configurationsThe ServiceFree connection design is just a small part of Lindapter s service.

6 We offer comprehensive design and support, tailoring our products to your application: 3D>Free design proposal2D / 3D drawingsQuotationSupplyInstallation guidance>>>>> For simple Girder Clamp connections try the Assembly Selector today at <<Contact Lindapter todayTech Support: / General Enquiries: / T: +44 (0) 1274 521444 What we BeamFlange Width = 203mmFlange Thickness = BeamFlange Width = 102mmFlange Thickness = 6mm 10 116 218 180 270 14 THRUDETAIL A SCALE 1 : x 70mm Long Setscrew, PropertyClass , with Class 8 Nut & Plain WasherLindapter B12L ClampLindapter A12M ClampLindapter P1S12 PackerLocation PlateFor combined loadings the current relevant nationalstandard should be taken into consideration Assembly Data:Static Tensile SWL = kNFactor of Safety :5 : 1 Static Slip Resistance SWL = kNFactor of Safety :5 : 1 Lindapter Fastener Tightening Torque =69 NmGC001-1 connection DetailsDWG.

7 TITLEGENERAL NOTES:NOT TO SCALEDO NOT SCALE THIS DRAWING AND THE COPYRIGHT THEREIN ARE THE OF LINDAPTER INTERNATIONAL. IT IS ISSUED ON THE CONDITION THAT IT MUST NOT BE USED, COPIED, DISTRIBUTED OR EXHIBITED WITHOUT WRITTEN PERMISSION AND CONSENT. THE DRAWING MUST ALSO NOT BE USED FOR ANY OTHER PURPOSE THAN WHICH IT IS IS THE RESPONSIBILITY OF THE ENGINEER TO PERFORM REASONABLE CHECKS ON THE SUPPORTING AND SUPPORTED MEMBERS. THAT IS LOCAL TO THE connection AND THE LINDAPTER COMPONENTS, BOTH FOR THE LOAD APPLIED AND THE CLAMPING FORCE GENERATED FROM THE TIGHTENING OF THE NECESSARY WORKMANSHIP FOR ITEMS SHOWN THIS DRAWING SHOULD COMPLY WITH THE RELEVANT SECTIONS OF THE national structural steelwork specification (NSSS) FOR BUILDING CONSTRUCTION 5TH EDITION CE MARKING FELT NECESSARY, WHERE EXCESSIVE VIBRATION MAY BE CONCERN, IT IS ACCEPTABLE FOR CERTAIN TYPES OF ANTI-VIBRATION LOCKING DEVICES SUCH AS, BUT NOT LIMITED TO, PROPRIETARY WASHERS AND NUTS TO BE USED WITH LINDAPTER COMPONENTS AND/OR ASSEMBLIES.