Pin Connector (RCA)BNC straight right-angle straightN (S)COAXIALCRIMPCONNECTORASSEMBLYPROCEDUR ES ( die casting)( slim type)F TNCCANARECRIMPCONNECTORS TEL045-470-5565 FAX045-470-5567 A ( 2) ( 4) ENGLISH ( 3) ( 1) ( 5) (Note6)Ifusingcoaxialcable "3C-2T", cut off the overalltapebetweenthe braided shields as far asposition A, as shown in Fig.

Pin Connector (RCA) BNC ストレートstraight 圧着式コネクタ取付法 ライトアングルright-angle ストレートstraight N (S) COAXIAL CRIMP CONNECTOR

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of 圧着式コネクタ取付法 - CANARE

1 Pin Connector (RCA)BNC straight right-angle straightN (S)COAXIALCRIMPCONNECTORASSEMBLYPROCEDUR ES ( die casting)( slim type)F TNCCANARECRIMPCONNECTORS TEL045-470-5565 FAX045-470-5567 A ( 2) ( 4) ENGLISH ( 3) ( 1) ( 5) (Note6)Ifusingcoaxialcable "3C-2T", cut off the overalltapebetweenthe braided shields as far asposition A, as shown in Fig.

2 1.(Note5)Makesuretheinner conductor is free of allinsulationdebrisandoffcuts to ensure completecrimping.(Note4)Removeallstray strands and offcuts of thealuminumfoilshield to avoid possible shortcircuiting.(Note2)Foracrimpsleevewi thsteps, slip it over thecablefromthesteppedend,as in the diagram.(Note3)Ifanyaluminumfoilshield is left on the cable,itmaygetstuckinthemouth of connector, makinginsertion cablepriortoassembly.(Note1)Forcableswit hstrandedinner conductor, twist thestrandsinthesame direction as plied afterremoving the stripthesheath,braidedshield,andinsulati onof cableswithanaluminumfoilshield,stripthes hieldasfaraspositionA,asshowninFig. 2. BCP-C7A,C7FA, C71A, C5 HDFP-C7FA, C71A( 7) RCAP-C, BCP-A, B, D, LC, FP-C,( 8) ( 9) < > BP-C,LC, TNP-C, LCNP-C, LC, SP-C, SJ-CBP-C5FA,C51F, SP-C5F,NP-C5F, C51F( 10) ( 2kgf ) 3.

3 4. ( ) ( 11) oninnerconductorofthecableandcrimp thecentercontactatthecorrectposition(wit houtremainingagap)asshownin die.(Note9)Confirmthecentercontact pin is crimpedstraighttothecenterconductor. If the centercontactpinis slanted, align it gently.(Note7)Toconfirmthecrimping properly, measure thecrimpheightafterremoving burrs with a standards,(see the lefttable) adjust the crimping tools.<crimp height value>(Note8)Donotcrimpthe center contact at the steppedroot end.(Note11)Donotpullthecablewhile crimping is executed.(Note10)Pullthecablegently(less than or )to confirm that is connectorbodyuntilthecentercontactpinisl ocked thecrimpsleeveandcrimpinplace,using thespecifiedcrimptool and (camberless)sideofthedie ELECTRIC CO.

4 , ( 6) 3C 2T A 19( )( )( ) ( 5 Note5) stray strands overall tapeBNC Example for BNC insulation debris and offcuts braided shield sheath aluminum foil shield camber side of die gap insulation( 2 Note2) center contact pin9 wrong spot ( )braided shield( 6 Note6)A position A crimp sleeve inner conductor Measure crimp slanted correct( 4 Note4) crimp crimpmm(inch)