Example: dental hygienist

Capture - Immucor

Capture . Trusted Everyday, 40 million times a year in North America alone, labs continue to express their well found confidence in the easiest, most dependable technology available. Transfuse | Transplant | Transform a life Capture . Test Procedure Grading chart For over 30 years, thousands of labs across the world have trusted ANTIGEN-COATED WELL. Capture solid phase technology. In fact, Immucor , the proven leader Hemagglutination Capture . in blood bank automation, brings you solid phase technology so PLASMA OR. SERUM. LISS. reliable, Capture -R Ready-Screen is the method for screening approximately 98% of the North American blood supply. With a full 4+. line of assays to suit your specific needs and innovative equipment to facilitate and automate the process Capture becomes the only INCUBATE.

Test Procedure Grading Chart. Hemagglutination. Capture ® 4+ 3+ 2+ 1+ 0. ANTIGEN-COATED WELL PLASMA OR . SERUM LISS. INCUBATE WASH. INDICATOR RED CELLS CENTRIFUGE

Tags:

  Chart, Capture

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Capture - Immucor

1 Capture . Trusted Everyday, 40 million times a year in North America alone, labs continue to express their well found confidence in the easiest, most dependable technology available. Transfuse | Transplant | Transform a life Capture . Test Procedure Grading chart For over 30 years, thousands of labs across the world have trusted ANTIGEN-COATED WELL. Capture solid phase technology. In fact, Immucor , the proven leader Hemagglutination Capture . in blood bank automation, brings you solid phase technology so PLASMA OR. SERUM. LISS. reliable, Capture -R Ready-Screen is the method for screening approximately 98% of the North American blood supply. With a full 4+. line of assays to suit your specific needs and innovative equipment to facilitate and automate the process Capture becomes the only INCUBATE.

2 Logical choice for antibody screening and identification. 3+. Flexible Flexible workflow capabilities with manual or automated options (NEO and Echo ). Run a single sample or a full batch WASH. Easy to Use Reliable Capture microplates have an IgG specific technology 2+. average shelf life of 120 days clearly detects clinical Pre-coating of antigens, significant antibodies INDICATOR RED CELLS. eliminates unnecessary Sensitivity and specificity are handling of red cell panels higher than manual tube or gel Ready to use reagents methods CENTRIFUGE. No precision pipetting Easily distinguish between Same methodology and Antigens are negative and positive results Allows processing of SIDE VIEW 1+.

3 Pre-coated on procedures for all assays, allowing standardization of hemolyzed, rouleaux, lipemic testing and ease of training microplate wells or icteric samples Capture LISS changes color assuring sample addition TOP VIEW. Controls on each run assures validity of test procedure Quick Results Results are stable for 0. Samples screened in as little two days as 25 minutes Cost Efficient Batch processing allows Competitively priced STRONG WEAK. throughput of several hundred NEGATIVE. Microplate technology is POSITIVE POSITIVE. tests per hour easily automated, leading to higher lab productivity Capture Workstation . Specifications ImmuSpin: P2 Incubator: CSW 100: Product (Rotor Only) Product Product The Capture Workstation allows antibody screening Six Simple Steps Operating temperature 5 to 40 C.

4 0015159 (Centrifuge) Incubation Temperature 36-38 C. Operating Conditions 18-25 C Operating temperature 10 to 40 C. and identification to be more efficient: Dimensions W/L/H 11 x x inches Dimensions W/L/H 12 x 12 x inches Dimensions W/L/H 11 x x inches Capacity Centrifuges Capture -type Incubation Bays 2 Capacity Washes Capture type 1 2. P2 Incubator This dual bay incubator micro-strips anywhere Weight 7 lbs. microstrips anywhere between 1 and 12 strips Type of Microplates Capture -type with 8 between 1 and 12 strips means there's no bottleneck during test Weight 25 lbs. wells per strip/or 16 Fluid reservoir capacity 2L. processing. You can process multiple runs Power Supply 110-127 V~ (+/- 10%), 50- wells per double-strip Weight 12 lbs.

5 60Hz, 5 A, 360 W Power Supply 99-132 VAC / 198-264 VAC, simultaneously, allowing you to continuously Minimum Timer Setting 1 min Programming Four (4) programs Temperature Resolution C 50-60Hz. process your dynamic workflow. Noise level 58 66 dB (A) Power Supply 100-240 VAC, 50-60Hz, Programming Two (2) washing programs A (P1 and P2). CSW 100 This automated cell washer is Add LISS Add Patient Sample preprogrammed for optimal performance, Remove strip from foil Using a routine blood and the wash cycle is less than 30 seconds pouch. Appropriate anti- bank pipette, add one gens for the test are pre- drop of donor/patient per strip. Capture 's wash step allows the coated on the well.

6 * Add plasma. Add one drop of processing of hemolyzed, rouleaux, lipemic two drops of Capture LISS. controls. or icteric samples. *If using Capture -P or Capture - ImmuSpin This centrifuge has a digital R Select , prepare platelet or red cell monolayer first. display for easy reading. Centrifugation time is less than 3 minutes for all Capture assays. 3 4. Capture features a versatile test menu and flexible workflow capabilities with manual or automated options. Immucor offers your laboratory an efficient test method which provides standardized test results with higher sensitivity and specificity than Incubate Wash manual tube or gel. Incubate test strips in P2.* Wash test strips in the automated washer.

7 *except Capture -CMV which requires incubation at room temperature. 5 6. Results Add Indicator Cells Centrifuge and Read Negative Result: Add one drop of indicator Results No antibodies bound to cells to each of the test Centrifuge test strips. wells, indicator cells will wells. Read reactions. migrate to bottom of the well and form a tight button. Positive Result: Required Capture Workstation Equipment *All Capture equipment supports Capture -R , Capture -P , and Capture -CMV products. Antiglobulin-coated indicator cells bind to antibody-coated wells forming an intact layer of cells on the well surface. Immuspin Centrifuge CSW100 Washer P2 Incubator Light Box Product codes: Product code: 0005175 Product code: 0030205 Product code: 0005133.

8 0015158 (Rotor only), 0015159 (Centrifuge) The continuous flow of this Two incubation bays means With 5000K color-corrected lamps This centrifuge accommodates up to 12 cell washer assures accurate, there's no bottleneck during test and an angled platform to optimize Capture microstrips and spins at rates consistent plate washing. The unit processing. You can process viewing, this light box makes ranging from 500 to 18,000 RPMs. For accommodates one microplate or multiple runs simultaneously, results extremely easy to read. easy reading, it has a digital display. up to 12 microstrips. The washing allowing you to continuously cycle takes less than 30 seconds process your dynamic workflow.

9 Per strip and the pre-programmed settings are optimized for Capture . technology. Product Line Assays Capture -R Ready-Screen Assays: Reagent red cells (in the form of red cell stroma) are bound to test wells at the time Capture -R Select Product Code Description Size of manufacture. The user is not required to prepare reagent monolayers before testing. Capture -R Ready-Screen tests are provided in 1 x 8 strips of microwells. Each microplate contains twelve 1 x 8 strips. Capture -R Select provides modified 0006446 Capture -R Select 5 plates/480 tests microwells for the immobilization of Capture -R Ready-Screen (I and II): Product Code Description Size human erythrocytes. To be used in solid phase assays for the detection of Contains alternating wells coated with 0006439 Capture -R Ready-Screen (I and II) 1 plate/ 48 tests IgG red cell antibodies ( , antibody red cell membranes from one of two 0006440 Capture -R Ready-Screen (I and II) 5 plates/240 tests screening, selected red cell panels, group O donors.)

10 Each strip consists 0066207 Capture -R Ready-Screen (I and II) Dia* 1 plate/48 tests autologous controls, direct antiglobulin of eight individual wells to perform four test, crossmatching, or typing with IgG. (2-cell) antibody screens. 0066217 Capture -R Ready-Screen (I and II) Dia* 5 plates/240 tests anti-sera including weak D detecting 0066202 Capture -R Ready-Screen (I and II) Cw* 1 plate/48 tests reagents). 0066212 Capture -R Ready-Screen (I and II) Cw* 5 plates/240 tests Capture -P Ready-Screen Product Code Description Size Capture -R Ready-Screen (3): Product Code Description Size Consists of a 2 x 8 strip of microwells 0066247 Capture -P Ready-Screen 1 Plate/6 tests Contains alternating wells coated with 0066803 Capture -R Ready-Screen (3) 1 plate/ 24 tests to which the platelet membranes of 0066240 Capture -P Indicator Cells 1 x mL.


Related search queries