Example: air traffic controller

Catalog Number Notes Type - Acuity Brands …

Ballast/TransformerADALIA dvance ROVR electronic controllable ballast utilizing digitaladdressable lighting interface (DALI) protocol. Requires four-pin lamp (120V or 277V only).TUBDALI Universal DALI-Pro dimming ballast; MVOLT; 18W, 26W, 32W,or electronic fluorescent ballast. Requires four-pin lamp(120V or 277V only).ADEZA dvance Mark 10 electronic line voltage control dimming ballast.(120V or 277V; 18 DTT, 26 DTT, 18 TRT, 26 TRT, 32 TRT, 42 TRT or 57 TRTonly). Requires four-pin lamp. Minimum dimming level 5%.ADZTA dvance Mark 7 electronic 0-10 VDC dimming ballast. (120V or277V). Requires four-pin lamp. Minimum dimming level 5%.DMHLL utron Compact SE electronic 3-wire line voltage controldimming ballast. (120V or 277V; 18 DTT, 26 DTT, 18 TRT, 26 TRT,32 TRT or 42 TRT only.) Requires four-pin lamp. Minimum dimminglevel 5%.DMHL3 Lutron Hi-Lume electronic dimming ballast; voltage specific;one or 2 lamps with 26 TRT or 32 TRT; Minimum dimming level 1%.

Commercial Product Definitions Sheet #: Commercial Product Definitions Lithonia Lighting Downlighting One Lithonia Way, Conyers, GA 30012 Phone: 800 …

Tags:

  Notes, Definition, Catalog, Types, Number, Brand, Acuity, Acuity brands, Catalog number notes type

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Catalog Number Notes Type - Acuity Brands …

1 Ballast/TransformerADALIA dvance ROVR electronic controllable ballast utilizing digitaladdressable lighting interface (DALI) protocol. Requires four-pin lamp (120V or 277V only).TUBDALI Universal DALI-Pro dimming ballast; MVOLT; 18W, 26W, 32W,or electronic fluorescent ballast. Requires four-pin lamp(120V or 277V only).ADEZA dvance Mark 10 electronic line voltage control dimming ballast.(120V or 277V; 18 DTT, 26 DTT, 18 TRT, 26 TRT, 32 TRT, 42 TRT or 57 TRTonly). Requires four-pin lamp. Minimum dimming level 5%.ADZTA dvance Mark 7 electronic 0-10 VDC dimming ballast. (120V or277V). Requires four-pin lamp. Minimum dimming level 5%.DMHLL utron Compact SE electronic 3-wire line voltage controldimming ballast. (120V or 277V; 18 DTT, 26 DTT, 18 TRT, 26 TRT,32 TRT or 42 TRT only.) Requires four-pin lamp. Minimum dimminglevel 5%.DMHL3 Lutron Hi-Lume electronic dimming ballast; voltage specific;one or 2 lamps with 26 TRT or 32 TRT; Minimum dimming level 1%.

2 ECOSL utron EcoSystem compact fluorescent dimming ballast;voltage specific (120 or 277); one or 2 lamps with 26 TRT, 32 TRT or42 TRT. Minimum dimming level 5%.OSCFO sram Sylvania electronic fluorescent ballast. Requires four-pin Lighting Technologies electronic ballast. Requiresfour-pin GE Lighting compact fluorescent pro-line electronic ballast;Programmed rapid-start; MVOLT; one or 2 lamps 18 DTT/TRT or26 DTT/TRT; one lamp 32 TRT or transformer (277V to 120V; 300W max.).RIF1 Radio inference filter. Inductive capacitor circuit designed tominimize interference from feedback into line. 120V through347V, 50 or 60 Ballast disconnect plug meets codes that require Emergency battery pack with integral test switch. Shipsstandard for 1-lamp operation. For 2-lamp emergencyoperation, consult installation instructions or Emergency battery pack with remote test switch.

3 Shipsstandard for 1-lamp operation. For 2-lamp emergencyoperation, consult installation instructions or lumen output emergency battery pack. Integral test lumen output emergency battery pack. Remote test switchprovided. Not recommended for field battery pack with remote test switch. Operates two26W, two 32W or two 42 CFL lamps in emergency mode with batteryback-up in case of power disruption. Average output is 2,600lumens for two 26W lamps; average output is 2,750 lumens for two32W lamps. average output is 2800 lumens for two 42W lampsBGTDB odine GTD generator transfer device. Factory installed onfixture, senses loss of normal power and switches to auxiliarygenerator to power fixture for egress NumberNotesTypeDownlighting and TrackSheet#: Commercial Product DefinitionsCommercial Product OptionsDEFINITIONSF usingGMFS ingle, slow-blow fuse.

4 (120V, 277V or 347V only.). For use withfluorescent fixtures fuse (120V, 277V or 347V only).TrimTRW White painted painted Lamp (shipped separately).LPSP Spot lamp (shipped separately).LPFLF lood lamp (shipped separately).LPWFLWide flood lamp (shipped separately).MiscellaneousA T Sealed airtight housing to minimize air flow through with WSEC and certified per ASTM See PSG10 page 295; no See PSG10 page 295; no Filter/Specialty Lenses: See PSG page 295, no when ceiling thickness is greater than 1-1/2". Maximumthickness 2". For use with 6" vertical reflectors Use when ceiling thickness is greater than 1-1/2". Maximumthickness 2". For use with 8" vertical reflectors " Use with F6 and 6 Series trims. Compatible with all 7-5/8" flanged trims Product DefinitionsSheet #: Commercial Product DefinitionsLithonia LightingDownlightingOne Lithonia Way, Conyers, GA 30012 Phone: 800-315-4935 Fax: 2010 Acuity Brands Lighting, Inc.

5 All rights reserved. 2/8/10