Example: bachelor of science

Catalogue 2000 ALSPA Drives /2001 - ALSINTEC

Power DrivesCatalogue 2000 /20012 ALSTOM Power Conversion23, avenue de Neuilly75116 ParisFranceTel :+33 (0) 1 40 67 58 00 Fax : +33 (0) 1 40 67 58 71 France9, rue Amp re 91345 Massy CedexTel: +33 (0) 1 60 13 24 43 Fax: +33 (0) 1 60 13 20 02 GermanyCulemeyerstra e 1D-12277 BerlinTel: +49 (0) 30 74 96 27 00 Fax: +49 (0) 30 74 96 27 08 UKBoughton Road, Rugby Warwickshire, CV21 1 BUTel: +44 (0)1788 563 625 Fax: +44 (0)1788 563 780 USA610 Epsilon DrivePittsburgh, PA 15238 Tel: +1 412 967 0765 Fax: +1 412 967 766047 - ALSTOM - 2000 . Publication No. POWC/PROS/ALSP/uke/ ALSTOM, the ALSTOM logo and any alternative version thereof are trademarks and service marks of ALSTOM. The other names mentioned, registered or not, are the property of their respective company is listed on the Paris,London and New York stockexchanges.

The company is listed on the Paris, London and New York stock exchanges. *The transaction is subject to customary regulatory approvals. General Drives

Tags:

  Drive, 2010, Catalogue, 2000, Catalogue 2000 alspa drives 2001, Alspa

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Catalogue 2000 ALSPA Drives /2001 - ALSINTEC

1 Power DrivesCatalogue 2000 /20012 ALSTOM Power Conversion23, avenue de Neuilly75116 ParisFranceTel :+33 (0) 1 40 67 58 00 Fax : +33 (0) 1 40 67 58 71 France9, rue Amp re 91345 Massy CedexTel: +33 (0) 1 60 13 24 43 Fax: +33 (0) 1 60 13 20 02 GermanyCulemeyerstra e 1D-12277 BerlinTel: +49 (0) 30 74 96 27 00 Fax: +49 (0) 30 74 96 27 08 UKBoughton Road, Rugby Warwickshire, CV21 1 BUTel: +44 (0)1788 563 625 Fax: +44 (0)1788 563 780 USA610 Epsilon DrivePittsburgh, PA 15238 Tel: +1 412 967 0765 Fax: +1 412 967 766047 - ALSTOM - 2000 . Publication No. POWC/PROS/ALSP/uke/ ALSTOM, the ALSTOM logo and any alternative version thereof are trademarks and service marks of ALSTOM. The other names mentioned, registered or not, are the property of their respective company is listed on the Paris,London and New York stockexchanges.

2 *The transaction is subject tocustomary regulatory DrivesThe Power Conversion Sector ofALSTOM provides a full range ofdrives and automation for allvariable speed applications,including pumps, fans, compressorsand extrusion machines, with arange of more than 100megawatts. ALSTOM Drives arewidely used in the oil, gas andcement industries; for watertreatment and waste applications;by distribution power utilities; andin a myriad of other is also a recognisedspecialist in the specification,design and installation of completedrive systems and powerelectronics for applications such astest benches, windmills, linearmotors, gas turbines, soft starters,high-speed compressors, frequencyconvertors, fuel cells and The CompanyThe ALSTOM GroupALSTOM is a world leader inthe energy and transportinfrastructure is organised in sixSectors, Energy, Transmission &Distribution, Transport, PowerConversion, Marine andContracting, all of these beingsupported by the offers a complete rangeof systems.

3 Components andservices covering design andmanufacture as well ascommissioning and long-termmaintenance and has uniqueexpertise in systems integration andmanagement of turnkey 31 March 2000 , ALSTOM announced the acquisition* ofABB s share of the 50-50 jointcompany, ABB ALSTOM acquired company becomesALSTOM Power, a new Sector of the closing date, ALSTOM will have a new combined turnoverof more than 20 billion euros andwill employ over 140,000 peoplein 100 Customer Support ServiceWe recognise the importance toour clients of providing an excellentlevel of customer support philosophy is based on theconcept that our relationship withcustomers is only just beginningwhen we complete commissioningof a system. It is vital for long termsuccess of our business that weoffer lifetime support.

4 Our service organisation aroundthe world is geared to workingclosely with clients to improve theirbusiness performance by ensuringoptimum operation of plant andsystems with increased availabilityand improved system services are tailored tomeet the needs of your specificindustry. For example, werecognise that the support needs ofour Marine customers are differentto those of our Metals structure and operation of ourservice organisation reflects thisand is adapted to offer a full portfolio of supportservices that can be tailored to suityour individual requirements. Theseinclude: 24 hour telephone helpline Emergency breakdown callout Remote diagnostics facilities Service and maintenancecontracts Spare parts supply and inventorymanagement Repairs Obsolescence management Training centres Maintenance engineering Plant and system optimisationservices Upgrades and enhancements 445 Soft StartersDNTAT echnical FeaturesTechnical FeaturesStart modeCurrent limited start-up, vector controlled start-upStop mode coastControlled deceleration (pumps)Motor protectionThermal protection, phase loss, unbalanced phases, Motor disabledMotor thermistor PTCPump protectionNo load running, lmin, fmaxMeasurementsV,I, Cos ,kW, accuracy 2%Energy consumptionkWh and run time (hours)

5 Special featuresPre-heating, anti over hauling energy saving, auto-restart on mains dipDigital inputsRun, stop, controlled deceleration, rapid stopAnalogue outputsI (Amp) or P (kW) as 4 20mA signalSerial linkModbus/Jbus, RS485, PC RS232 StandardsCE, EN 60947-1 EN 60947-4-2 EN 61000-4-2 EN 61000-4-3EN 61000-4-5 EN 61000-4-6 EN 61000-4-11 DNTAType 220-400-500-690V*Unit19/2537/4545/6060/7 585/100100/135140/175 Full load current class 10A254560751001351753 FLC Amb. 40 CFull load current class 20A19374560851001404 FLC Amb. 40 CWeightkg10101010101015 Physical dimensionsW mm175175175175175175295H mm245245245245245245287D mm210210210210210210270 DNTAType220-400-500-690V*Unit 175/200 250/380 300/380380/450450/600 600/750750/1000 Full load current class 10A20030038045060075010003 FLC Amb.

6 40 CFull load current class 20A1752503003804506007504 FLC Amb. 40 CWeightkg15253030505080 Physical dimensionsW mm295295371371370370565H mm287376440440652652820D mm270285308308310310418*OptionalProduct Range5 ContentsAC Drives ProductsALSPA MV500 - Control Simplicity - to 15kW6-11 ALSPA MV1000 - Intelligent Low Power Drives - to 45kW12-15 ALSPA MV3000 - A Revolution in drive Technology - 22kW to 315kW16-27 ALSPA MV3000 Delta - Air Cooled drive Modules - 315kW to Mounted Drives - 22kW to 30-31 ALSPA MD2000 AEM - Active Energy Management - to Voltage DrivesALSPA VDM & CDM34-35 SYNCHRODRIVE and Static Frequency Convertors - Control and Starting for Synchronous Motors36-37 CYCLODRIVE - Control of Induction of Synchronous Motors for Low Speed/High Torque Applications38-39DC DrivesALSPA

7 VNTC - Single Quadrant Digital Drives 25A to 1850 AALSPA WNTC - Four Quadrant Digital Drives - 25A to 1850A40-43 Soft StartersALSPA DNTA - 6 Pulse Digital Starter 19A to 1000A 44-45 SupportOur Customer Support Service46-4744 DNTAV ector Algorithm ControlledThe ALSPA DNTA 6-pulse digitalstarter using vector control is a newstep forward in starting inductionmotors. It efficiently gives motorsprogressive and optimum starting,as well as controlled process slowdown and increased SettingThe ALSPA DNTA soft starter is pre-set at the factory for standard use,and it gives additional settingsthrough its keypad. Access is giventhrough menus to all the parametersand states of the starter, motor andmains measurements and energycontrol make optimisation of start-up and stop settings much and Meets InternationalStandardsThe ALSPA DNTA soft startercontinuously monitors the motor byeither a thermal model or bythermistors.

8 It is protected againstshort-circuits and overloads, and isin agreement with classes shown ininternational ALSPA DNTA soft starter has astandard serial link forcommunicating with control devicessuch as PLCs and supervision Pumps- Start-up in Vector control < 3 FLC- No load run protection- Controlled deceleration,suppression of water hammer- Auto-restart on mains dip- Pre-heating Fans- Start-up in current limit- Auto-adaptable starting current,depending on the fan ratings,inertia, Optimum starting for allconditions Quarry Machine- Start-up of variable loadmachines- Start-up in current limit- Auto-adaptable starting current,depending on the : conveyors,crushers, grinders, Compressor- Start-up in current limit- Auto-adaptable starting current,depending on compressor load- Applications: reciprocatingcompressors, screw compressors,centrifugal compressors Generating plant- Motor start-up on generatingplant- Decrease of active and reactivepower- Reduced size of the generatorrequired- Important saving on capital costALSPA MV500 - Control Simplicity6 The ALSPA MV500 range of lowpower Drives brings reductions inboth cost and in complexity.

9 Nodrives knowledge is required toinstall and use ALSPA MV500 inmost addition to ease of installation, ALSPA MV500 provides ease ofoperation with only 10 parametersettings to cover most driveapplications. Additional menus canbe made available if ALSPA MV500 RangeProvides: simple installation and start up 230V and 400V operation withsingle and three phase input fast installation and convenientcable management non shaft rotating autotune toassist fast set up RS485 serial communications asstandard intelligent thermal managementensuring minimum motor noisewith maximum drive protection large power terminals for ease ofcabling pluggable terminals for fast access built-in braking transistor for fastdynamic braking (sizes B to D)Technical FeaturesMotor ConnectionsVoltage 3 phase:from zero to UmainsNominal motor voltage.

10 200V to 240V (single or three phase for 220V drive input)380V to 480V (three phase for 380/400V drive input)Nominal motor frequency:50:1 range 1000Hz maximumContinuous load capacity (constant torque) rated current 1nOverload x 1nfor 1 minute every 10 minutesSwitching frequency:standard 3kHz, 6kHz,12kHzAcceleration to 3200 seconds/100 HzDeceleration to 3200 seconds/100 HzProtection FunctionsOvercurrent tripOvervoltage tripUndervoltage tripCurrent 12t protectionOvertemperature limit (heatsink)Earth fault protection on outputOutput short circuit protectionPower loss ride throughSerial communications failureLoss of analogue signalITMC ontrol ConnectionsAnalogue inputs:voltage signal: 0 to 10V/100k current signal: 0(4) to 20mA/200k Analogue outputs:0 to 10 VAuxiliary voltage:24V/100mADigital inputs:12V DC PNP and NPN logic24V DC PNP and NPN logicinput impedance sample time output:24V maximum 50mARelay output:switching voltage 30 VDC/240 VAC,6A/2A resistiveSerial communicationsRS232, RS485 Options.


Related search queries