Innovators in Protection TechnologyInnovators in Protection Technology[1]INDUSTRIAL SWITCHGEAR & AUTOMATION SPECIALISTSP owerDistribution [CATALOGUE TB2-CAT] TEMBREAK 2 MOULDED CASE CIRCUITBREAKERSB eyond the Standard in Protection TechnologyMOULDED CASE CIRCUIT BREAKERSI nnovators in Protection TechnologyInnovators in Protection Technology[2]MAIN CONTACT / TOGGLE STATUS VISIBILITYTemBreak 2 MCCBs are marked with the IEC symbol indicating Direct Opening Action. The robust mechanism ensures that the force applied to the toggle is transmitteddirectly to the and Machine SafetyComplies with direct actioncontact status (I)OFF (O)TRIPPEDO pening forceis transmitteddirectly fromthe toggleswitchContactsseparatedMaintenance can beperformed onthe load theStandard Easy accessory fitting Double insulated MCCB 125 / 250 A adjustment flexibility Clear contact status Symmetrical design Elec / Mech endurance Low temperature rise Higher harmonic immunity High insulation voltageMOULDED CASE

MOULDED CASE CIRCUIT BREAKERS Innovators in Protection Technology [3] TEMBREAK 2 Positive OFF/ON operation. The toggle mechanism is directly driven by

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of [CATALOGUE TB2-CAT] TEMBREAK 2 MOULDED …

1 Innovators in Protection TechnologyInnovators in Protection Technology[1]INDUSTRIAL SWITCHGEAR & AUTOMATION SPECIALISTSP owerDistribution [CATALOGUE TB2-CAT] TEMBREAK 2 MOULDED CASE CIRCUITBREAKERSB eyond the Standard in Protection TechnologyMOULDED CASE CIRCUIT BREAKERSI nnovators in Protection TechnologyInnovators in Protection Technology[2]MAIN CONTACT / TOGGLE STATUS VISIBILITYTemBreak 2 MCCBs are marked with the IEC symbol indicating Direct Opening Action. The robust mechanism ensures that the force applied to the toggle is transmitteddirectly to the and Machine SafetyComplies with direct actioncontact status (I)OFF (O)TRIPPEDO pening forceis transmitteddirectly fromthe toggleswitchContactsseparatedMaintenance can beperformed onthe load theStandard Easy accessory fitting Double insulated MCCB 125 / 250 A adjustment flexibility Clear contact status Symmetrical design Elec / Mech endurance Low temperature rise Higher harmonic immunity High insulation voltageMOULDED CASE CIRCUIT BREAKERSI nnovators in Protection Technology[3] TEMBREAK 2 Positive OFF/ON toggle mechanism is directly driven bythe MCCB main contacts.

2 The label logobelow indicates this MCCB range From 50 A to 630 A 2 frame sizes: 250 A and 400/630 AThermal Magnetic orElectronic Trip unitsCommon internalaccessories 125 - 630 AAll internal and externalaccessories are fieldinstallableThermal Magnetic125 A, 250 A and 400 A MCCBs MCCBs are fitted with adjustable thermal AND adjustable magnetic current adjustment dialsSimply flexibleNJ6253650256253050192250 AGJ6506585406253385402585A1NF--25*25---1 3*13--25*AE1253, 4NJ-15253525-12192719835AH1253, 4NJ2085125150401565851504045150L1253, 4NJ2512520020040201001501504065200H1603, 4NJ2085125150401565851504045150L1603, 4NJ25125200200402010015015040652001NF--2 5*25---19*19--253, , (30)12068165105140103A A165(35)

3 14068A A A165105140103A165105140103AS1253, 4 MOULDED CASE CIRCUIT BREAKERSI nnovators in Protection TechnologyInnovators in Protection Technology[4]ELECTRICAL CHARACTERISTICSA ccording to IEC 60947-2, EN 60947-2, JIS C 8201-2, AS/NZS 3947-2, NEMAM aximum rated currentModelNumber of polesTypeRated Breaking CapacityRated Breaking Capacity, NEMAO utline DimensionsUtilisation CategoryAvailable Protection UnitsThese characteristics are the same for all products on this AC and DC insulation voltage UiV800 Rated impulse withstand voltageUimpkV8 Rated operational voltageUeVAC 690 Suitable for isolationYesDirect opening actionYes* Breaking capacity shown is at 1/ 3 times the standard 2 switch-disconnectors are available with the sameframe dimensions as the thermal, adjustable magneticFixed thermal.

4 Fixed magneticMicroprocessorUnitsAkAkAkAmmmmmm mmCondition45/50 C690 V AC440 V AC380/415 V AC220/240 V AC250 V DC690 V AC440 V AC380/415 V AC220/240 V AC250 V DC480 V AC240 V AC3 pole, (1 pole)4 A to 125 A application12 A to 250 A applicationE2503, 4NJ-15253525-121927191035E4003, 4NJ-22253525-222535191535E6303, 4NE10253650-10253650-1550CE20455085-1545 5085-2585GE205070100-15455085-30100S4003 , 4H4003, 4L4003, 4S6303, 4CJ153036504015303650402250S2503, 4H2503, 4NJ2085125150401565851504045150L2503, A A A165105140103A A260140185103A A A A A A A A A A260140185103A A AMOULDED CASE CIRCUIT BREAKERSI nnovators in Protection Technology[5]

5 250400630NJ204550854015455085402585NE203 05085-15455085-2585GJ2050701004015455085 4030100GE205070100-15455085-30100NJ35851 25150403565851504045150NE3585125150-3565 85150-45150NJ501252002004050100150150406 5200NE50125200200-50100150150-65200125 A to 630 A applicationMOULDED CASE CIRCUIT BREAKERSI nnovators in Protection TechnologyInnovators in Protection Technology[6]INTERNAL ACCESSORIESSMARTACCESSORIESG eneral purpose typesHeavy duty typesAuxiliaryAuxiliaryAlarmShuntUVTA larmSIMPLY SAFE Common accessory range from 125AF to 630AF Double insulated MCCB allowing accessory fitting while live TEMBREAK 2 accessory types reduce part numbers, stock, make supply more customer friendly, reduce lead times All accessories meet IEC 60 947-5, AS/NZS 3947-5 Endurance tested accessories - not normally done by many manufacturersOne size fits all!

6 MOULDED CASE CIRCUIT BREAKERSI nnovators in Protection Technology[7]EXTERNAL ACCESSORIEST ransfer switchLink interlockAllows for handles andmotors to be mountedTransfer switchWire interlockHorizontal, vertical or diagonalMCCB mounting allows for handlesand motors to be mountedMotor fittingSimple, quick installation inseconds requiring no toolson 125 A / 250 A MCCBs only requirea screwdriverVariable and fixed depthhandlesSimple, quick installation inseconds requiring no tools on 125A / 250 A MCCBs. Larger MCCB sonly require a screwdriver. IP 54or IP 65 handlesTerminal coversSlide-on and click intoplace, no tools requiredPlug in MCCBS afety interlock standard tomaximise safetyTemPlugA simple plug in method forMCCBs 125 A to 630 ASimple to fitInnovators in Protection TechnologyELECTRICAL ENGINEERING PRODUCTS PTY LTD 84 004 304 812 NEW SOUTH WALESSYDNEY30-34 Day Street North Silverwater New South Wales 2128 Telephone +61 2 9748 3444 Fax +61 2 9648 4353 Email NEWCASTLE575 Maitland Road Mayfield West New South Wales 230 Telephone +61 2 4960 2220 Fax +61 2 4960 2203 Email AUSTRALIAADELAIDE36-38 Croydon Road Keswick South Australia 5035 Telephone +61 8 8297 9055 Fax +61 8 8371 0962 Email AUSTRALIAPERTH38 Belmont Ave Rivervale Western

7 Australia 6103 Telephone +61 8 9277 1777 Fax +61 8 9277 1700 Email NORTHERN TERRITORY DARWIN 3 Steele Street Winnellie Northern Territory 0820 Telephone +61 8 8947 2666 Fax +61 8 8947 2049 Email Lockhart Place Mt Wellington Auckland Telephone +64 9 276 1967 Fax +64 9 276 1992 Email Gasson Street Sydenham Christchurch Telephone +64 3 377 4407 Fax +64 3 377 4405 Email HEADQUARTERS43-67 River Street Richmond Victoria 3121 Telephone +61 3 9429 2999 Fax +61 3 9429 1075 Email DISTRIBUTION AND MANUFACTURING CENTRE104-106 William Angliss Drive Laverton North Victoria 3026 Telephone +61 3 9429 2999 Fax +61 3 9368 2997 Email TASMANIAHOBART2/65 Albert Road Moonah Tasmania 7009 Telephone +61 3 6228 9575 Fax +61 3 6228 9757 Email Riverview Place Murarrie Queensland 4172 Telephone +61 7 3909 4999 Fax +61 7 3399 9712 Email Leyland Street Garbutt Queensland 4814 Telephone +61 7 4779 0700 Fax +61 7 4775 1457 Email Robison Street Rockhampton Queensland 4701 Telephone +61 7 4927 2277 Fax +61 7 4922 2947 Email Cnr Carroll St & Struan Crt Toowoomba Queensland 4350 Telephone +61 7 4634 4799 Fax +61 7 4633 1796 Email 2/1 Bramp Close Portsmith Queensland 4870 Telephone +61 7 4035 6888 Fax +61 7 4035 6999 Email Catalogue - TB2-CAT 09/06 Copyright NHP 2006