Central Battery System Type CPS 220/SV - INOTEC

Central Battery System Type CPS 220/SV . Catalogue CPS 220/SV . Sicherheitstechnik GmbH. CPS 220/SV . The modular emergency lighting System INOTEC Sicherheitstechnik GmbH is a company with the target to create innovative and customer oriented solutions for the Emergency Lighting market. A dynamic team of highly professional and flexible employees covers all aspects regarding products, engineering and standards. Modern, technical advanced products set new standards world wide, JOKER technology Content for Emergency Lighting Systems or the cps 220 The modular emergency lighting System Dynamic Escape Routing concept realised in the Page Function, design and features 3-4. This catalogue contains the INOTEC Standard Central Battery Emergency Lighting Systems Advantages and function of (CPS) and some complementing products. Joker-technology 5. Should you require additional functions or Installation sample 6-7.

CPS 220/SV Function, design and features 220 V-central battery system with fully automatic function monitoring including individual lamp- and circuit failure detection

Tags:

  System, Types, Central, Battery, Cps 220, Central battery system type cps 220

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Central Battery System Type CPS 220/SV - INOTEC

1 Central Battery System Type CPS 220/SV . Catalogue CPS 220/SV . Sicherheitstechnik GmbH. CPS 220/SV . The modular emergency lighting System INOTEC Sicherheitstechnik GmbH is a company with the target to create innovative and customer oriented solutions for the Emergency Lighting market. A dynamic team of highly professional and flexible employees covers all aspects regarding products, engineering and standards. Modern, technical advanced products set new standards world wide, JOKER technology Content for Emergency Lighting Systems or the cps 220 The modular emergency lighting System Dynamic Escape Routing concept realised in the Page Function, design and features 3-4. This catalogue contains the INOTEC Standard Central Battery Emergency Lighting Systems Advantages and function of (CPS) and some complementing products. Joker-technology 5. Should you require additional functions or Installation sample 6-7.

2 Special features please do not hesitate to ask our regional technical sales team for support. System components and options 8-12. Control module Charger Circuit change-over devices Stairwell light switch module TLS. Relay interface RIF 5. Light switch monitors Phase monitors Luminaire monitoring and supply modules 13-15. Low voltage halogen LED - Power Led Electronic ballasts Monitoring modules External supervision and display 16-17. Mimic panel, wall MTB/AP. Mimic panel, recessed MTB/UP. InoWeb / InoLan / InoWeb-Control RTG interface Copyright: INOTEC Sicherheitstechnik GmbH, Ense Publications and copies, even partial, only with Technical data, systems overview 18-20. manufacturers permission. Designs sample, System engineering and tables 21-23. Subject to technical changes. CPS 220/SV . Function, design and features 220 V- Central Battery System with fully automatic function monitoring including individual lamp- and circuit failure detection without additional data line Internal and external System -bus Automatic System configuration Individual monitoring- and change-over devices for maintained- /non- maintained light Simple design and engineering due to free selectable luminaire operation modes Patented "Joker-Technology" function for mixed operation of maintained, non-main- tained and switched luminaires on one line Included logbook for all relevant data within a minimum 2 year period Centronics printer interface Lead acid gas recombination OGi- Battery with >10 years design life Mains CPS 220/SV .

3 Mains monitoring INOTEC . Controller Betrieb Betrieb SV-ZENTRALE. Betrieb 12:00. Funktionstest 8:30. Emergency and safety luminaires St rung with display Ladest rung Drucker Cetronics Key-board Charge monitoring Netz Batterie Netz 10AT. Ein Emergency and safety luminaires Charger Change-over modules Battery 220V. Function principle: With functional mains all connected consumers are supplied with mains and the Battery is charged / monitored. If mains fails or a partial light or circuit failure is detected the supply is triggered by the emergency lighting System . 3. CPS 220/SV . Function, design and features The cps 220 series covers various load requirements and housing sizes. Joker-Technology, individual lamp- and circuit monitoring are our standard System features Modular design, various enclosure sizes for main-, sub-stations, Battery -racks and Battery enclosures 19" inch - rack modules Isolation terminals for easy connection and insulation resistance measurement of luminaire circuits Load for standard systems: from 1,5 KVA to 22 KVA.

4 Compact design: Up to 48 circuits 3A (max. 576 monitored luminaires at 12 luminaires per circuit) or 24. circuits 6A on one System controller Low maintenance and service costs due to Central monitoring of stations and all connected luminaires Automated or manually releaseing function test facility with logbook for status and failure information Earth failure measurement and test facility Control module for the program- Technical data: ming, data processing and Mains supply: information storage, with: CPS Funktionstest 1~/N/PE, 230V AC, 10%. Betrieb U=247V I= or 4 line liquid crystal text display 6-03 14:59 Menue 3~/N/PE, 400V AC, 10%. free programmable via incorporated Emergency supply: buttons or external key-board 220V DC, +10/-20%. various languages available EMC protection to EN 55081/EN 55082. luminaire failure display with location info Protection class : I.

5 Luminaire function test and Battery duration test cycles free programmable Protection category : IP20. manual reset on mains return selectable Permissible ambient temperature: for System : -5 C to +35 C. delay on mains return (0 - 15 min) selectable for Battery : see datasheet deep discharge protection with info Connection possibilities to building management systems or in-house Central monitoring systems 4. CPS 220/SV . Advantages and function of Joker-technology Joker-technology - a cost saving innovation Advantages of the Joker - technology Each INOTEC CPS emergency lighting System can be built-up to three different supply Simple design and engineering luminaire switching modes on the same output at the same time. Luminaires with Joker Reduced installation material content high frequency electronic ballast (common standard on INOTEC -SV luminaires) or Joker Cut down on installation time switch modules, for third party electronic ballast, must be used.

6 These components allow Higher load level for final end circuits an easy setting of the monitoring address and luminaire mode. Switching mode settable on each luminaire The patented JOKER-technology of INOTEC . reduces the design- and installation time and cuts down on material cost. The sample pictured shows the kind of installation savings which can be achieved. Conventional systems and installations with the switching modes maintained-, non-maintained- and switched maintained mode, require 6 final end circuits to feed 9. luminaires in a part of the building shown. Circuit 1 Circuit 3 Circuit4 Circuit 2. Conventional installation requires The Joker-technology reduces the number of 6 final end circuits circuits required. Our sample needs only 2 final end circuits to feed the same number of luminaires due to the fact that the operation of all switching modes on one circuit is possible.

7 Circuit 5. The maintained and switched maintained Circuit 6. luminaires are active during mains presence. During mains failure, however, all luminaries, regardless of their operation mode, will be switched on and supplied by the Central Battery System . Circuit 1 Circuit 2. Joker technology with 2 final end circuits German Patentnumber: DE 19807844. European Patentnumber: EP 0939476 Maintained Non-maintained Switched maintained 5. CPS 220/SV . Installation sample Em-light Systems Status Functiontest: Complex installations with a multiple of INOTEC Standard Data line Durationtest: Button Operation Seminar room Select Button systems should be supervised from a SVPC- Software Operation Seminar room Operation System 3. Button Functions Button cen-tral location. Wether the INOTEC own RTG-BUS, an existing network or the Data line internet is used for this purpose depends Com-Port on the specific individual project requirements.

8 Status Functiontest: Em-light Systems Data line Durationtest: System address Status Operation Button Systemtype Location Seminar room Luminaire status Battery status Selection SVPC - Software Button max. 8x32 systems L1 L1. L2 L2. Button L3 L3. Luminaire location Workshop, mid-section Kitchen Toilett-men, gf N N. Toile Zur ck Status Functiontest: PE PE. Em-light Systems R T G/ +24V. Data line Durationtest: RS232. Work DB DB. reset RTG. Log book Button Sale INOTEC InoLan 990 063. GND RxD TxD. No. Date Time Address System Event 512 13:13 1 1 Operation Selection RTG. Safe manut 513 13:13 1 1 Operation or autom 514 13:14 1 1 failure Button interface 515 16:25 1 1 Operation InoLan DP DP . 516 16:26 1 1 failure 230V 50/60HZ U< S+ S- U< S+ S- 517 16:28 1 1 Funktiontest Button 518 09:16 1 1 DT interrupted Eintr ge insgesamt 520 Eintr g Status Functiontest: Funktiontest Op Em-light Systems Data line Durationtest: Durationtest Charge failure Fail Fail Button General General Transmission failure Blo Manual reset Discharge protection ISO.

9 Sys Workshop Selection lighting lighting Button Office Women Lager Kitchen Layout Men Button Sales dept. Seminar room Back Monitoring Mains Button MD. Engineering Sekrt. Help or 9 0 1. 8 2. 7 3. 6 5 4. 9 0 1. cps 220 . 8 2. 7 3. 6 5 4. Betrieb INOTEC . SV-ZENTRALE +. cps 220 Betrieb Betrieb 12:00. Betrieb INOTEC St rung Funktionstest 8:30. TEST. SV-ZENTRALE +. Ladest rung Drucker Cetronics Betrieb 12:00 - Betrieb R T. St rung Funktionstest 8:30. TEST Key-board UH. 5AT. Ladest rung Drucker Cetronics - R T. UH. INOWEB. Key-board SU / SV - J 2x3A SU / SV - 2x3A SU / SK - J 2x3A SU / SV - 1x6A SU / SK - 2x3A SU / SK - 1x6A SU / SV - 2x3A SU / SK - J 2x3A. 5AT. St rung Si 5AT St rung Si 5AT Si 5AT St rung Ein Ein BLEin Ein BLEin Ein Ein BLEin SU / SV - J 2x3A SU / SV - 2x3A SU / SK - J 2x3A SU / SV - 1x6A SU / SK - 2x3A SU / SK - 1x6A SU / SV - 2x3A SU / SK - J 2x3A Si 5AT Si 5AT Si 5AT.

10 St rung St rung DLEin St rung DLEin St rung St rung DLEin Ethernet- or Si 5AT Si 10AT Si 5AT Si 10AT Si 5AT. St rung Si 5AT St rung Si 5AT Si 5AT St rung Ein Ein BLEin Ein BLEin Ein Ein BLEin Si 5AT Si 5AT Si 5AT. Si 5AT Si 5AT St rung St rung Si 5AT. DLEin St rung DLEin St rung St rung DLEin St rung Ein St rung Ein Ein St rung Si 5AT Si 5AT Si 10AT Si 10AT Si 5AT. Si 5AT Si 10AT Si 5AT Si 10AT Si 5AT BLEin St rung BLEin St rung St rung BLEin R T G/ +24V DLEin Si 5AT DLEin Si 5AT Si 5AT DLEin Internet connection St rung Si 5AT. St rung Si 5AT Si 5AT. St rung RS232. Ein Ein Ein Si 5AT Si 5AT Si 10AT Si 10AT Si 5AT. BLEin St rung BLEin St rung St rung BLEin DLEin Si 5AT DLEin Si 5AT Si 5AT DLEin SU / SV - J 2x3A SU / SV - 2x3A SU / SK - J 2x3A SU / SV - 1x6A SU / SK - 2x3A SU / SK - 1x6A SU / SV - 2x3A SU / SK - J 2x3A. St rung Si 5AT St rung Si 5AT Si 5AT St rung Ein Ein BLEin Ein BLEin Ein Ein BLEin Si 5AT Si 5AT St rung St rung Si 5AT.