1 Uctions04/5804 R Centrifuge 5810/5810 REN)nstructions Register your instrument! 5804/5804 R Centrifuge 5810/5810 ROriginal instructions5820 Copyright 2019 Eppendorf AG, Germany. All rights reserved, including graphics and images. No part of this publication may be reproduced without the prior permission of the copyright is a registered trademark of Corning Inc., is a registered trademark of Becton Dickinson, and the Eppendorf Brand Design are registered trademarks of Eppendorf AG, is a registered trademark of Eppendorf AG, is a registered trademark of Eppendorf AG, is a registered trademark of Apacor Ltd, trademarks and protected trademarks are not marked in all cases with or in this Manual .
2 Design Patents are listed on of contentsCentrifuge 5804/5804 R Centrifuge 5810/5810 REnglish (EN)Table of contents1 Operating instructions .. this Manual .. symbols and danger levels .. symbols.. levels.. used .. used .. 82 Safety.. use .. profile .. limits .. concerning the ATEX directive (2014/34/EU) .. on product liability .. for intended use .. injury or damage to device.. handling of the centrifuge .. handling of the rotors .. strain on the Centrifugation tubes .. instructions on the device .. 153 Product description .. overview.. package .. plate .. 194 Installation.
3 The location .. installation .. the instrument .. 225 Operation.. controls.. for Centrifugation .. on the centrifuge .. the rotor .. rotor detection .. the rotor .. the centrifuge lid .. (only 5804 R/5810 R) .. adjustment .. display .. monitoring .. cooling .. 34 Table of contentsCentrifuge 5804/5804 R Centrifuge 5810/5810 REnglish (EN) Centrifugation .. Centrifugation in a fixed-angle rotor .. Centrifugation in a swing-bucket rotor .. with time setting .. in continuous operation .. spin Centrifugation .. the rotor .. mode .. 406 Operating controls and function.
4 The radius .. the acceleration and braking times .. the start of run time (At set rpm) .. the program.. the program.. the program .. functions .. Operating hours .. on/off the warning signal .. the service functions.. 447 Maintenance .. cleaning/disinfection .. and disinfecting the device .. and cleaning the rotor.. care instructions for refrigerated centrifuges .. glass breakage .. before shipment .. 498 Troubleshooting .. the excess current switch .. errors .. messages .. release .. 549 Transport, storage and disposal .. 565 Table of contentsCentrifuge 5804/5804 R Centrifuge 5810/5810 REnglish (EN)10 Technical data.
5 Power supply.. Ambient conditions .. Weight/dimensions .. Centrifuges .. Rotor weights .. Application parameters .. Service life of accessories .. Rotors .. Rotor A-4-81 (only 5810/5810 R) .. Rotor A-4-62 and A-4-62-MTP (only 5810/5810 R) .. Rotor A-4-44 .. Rotor A-2-DWP-AT (only 5810/5810 R) .. Rotor A-2-DWP .. Rotor FA-45-6-30.. Rotor F-34-6-38 .. Rotor FA-45-30-11 and F-45-30-11.. Rotor F-45-48-PCR .. Rotor T-60-11 .. Rotor S-4-104 (only 5810/5810 R) .. Rotor S-4-72 .. Rotor F-35-48-17 .. Rotor FA-45-48-11.
6 Rotor FA-45-20-17.. 9611 Ordering information .. Rotors .. Rotor A-4-81 (only 5810/5810 R) .. Rotor A-4-62 and A-4-62-MTP (only 5810/5810 R) .. Rotor A-4-44 .. Rotor A-2-DWP-AT (only 5810/5810 R) .. Rotor A-2-DWP .. Rotor FA-45-6-30.. Rotor F-34-6-38 .. Rotor FA-45-30-11 and rotor F-45-30-11 .. Rotor F-45-48-PCR .. Rotor T-60-11 .. Rotor S-4-104 .. Rotor S-4-72 .. Rotor F-35-48-17 .. Rotor FA-45-48-11.. Rotor FA-45-20-17.. Accessories .. Mains/power cord for Centrifuge 5804 and Centrifuge 5810 .. Mains/power cord for Centrifuge 5804 R and Centrifuge 5810 R.
7 10812 Annex .. 109 Certificates .. 113 Table of contentsCentrifuge 5804/5804 R Centrifuge 5810/5810 REnglish (EN)67 Operating instructionsCentrifuge 5804/5804 R Centrifuge 5810/5810 REnglish (EN)1 Operating this Manual Read this Operating Manual completely before using the device for the first time. Observe the instructions for use of the accessories where applicable. This Operating Manual is part of the product. Please keep it in a place that is easily accessible. Enclose this Operating Manual when transferring the device to third parties. The current version of the Operating Manual for all available languages can be found on our webpage symbols and danger symbolsThe safety instructions in this Manual have the following danger symbols and danger usedBiohazardExplosive substancesElectric shockRisk of crushingHazard pointMaterial damageDANGERWill lead to severe injuries or lead to severe injuries or lead to light to moderate lead to material Meaning in the specified order Actions without a specified order ListText Display or software
8 TextsAdditional informationOperating instructionsCentrifuge 5804/5804 R Centrifuge 5810/5810 REnglish (EN) usedMTPM icroplatePCRP olymerase Chain ReactionrcfRelative centrifugal force: g-force in m/s2rpmRevolutions per minuteUVUltraviolet radiation9 SafetyCentrifuge 5804/5804 R Centrifuge 5810/5810 REnglish (EN) useThe Centrifuge 5804/5804 R/5810/5810 R is used for the separation of aqueous solutions and suspensions of different densities in approved sample tubes. The Centrifuge 5804/5804 R/5810/5810 R is exclusively intended for use indoors.
9 All country-specific safety requirements for Operating electrical equipment in the laboratory must be observed. profileThe device and accessories may only be operated by trained and skilled using the device, read the Operating Manual and the instructions for use of the accessories carefully and familiarize yourself with the device's mode of concerning the ATEX directive (2014/34/EU)Due to its design and the environmental conditions inside the device, the Centrifuge 5804/5804 R/5810/5810 R is not suitable for use in a potentially explosive device may only be used in a safe environment, such as in the open environment of a ventilated laboratory or a fume hood.
10 The use of substances that may contribute to a potentially explosive atmosphere is not permitted. The final decision on the risks associated with the use of such substances lies with the on product liabilityIn the following cases, the designated protection of the device may be affected. Liability for any resulting damage or personal injury is then transferred to the owner: The device is not used in accordance with the Operating Manual . The device is used outside of its intended use. The device is used with accessories or consumables that are not recommended by Eppendorf . The device is maintained or repaired by persons not authorized by Eppendorf AG.