Example: barber

CenturyLink Corporation Technical Publication ...

CenturyLink Corporation Technical Publication Telecommunications Equipment Installation Guidelines Copyright 1993, 1996, 1997, 1998, 1999, 2000, 2001, 2003, 2007, 2016 77350 CenturyLink Corporation Issue O All Rights Reserved July 2016 CenturyLink Tech Pub 77350 Issue N, July 2016 Notice NOTICE This document describes CenturyLink s requirements for Suppliers of Central Office Equipment (Inside Plant ISP) Installation Services (herein referred to as the Service Supplier). The information provided in this document includes workmanship guidelines, Technical requirements, and Supplier competency requirements. CenturyLink Corporation reserves the right to revise this document for any reason, including but not limited to, conformity with standards promulgated by various governmental or regulatory agencies; utilization of advances in the state of the Technical arts; or to reflect changes in the design of equipment, techniques, or procedures described or referred to herein.

CenturyLink Tech Pub 77350 Table of Contents Issue O, July 2016 CONTENTS Chapter and Section Page 1. Introduction..... 1-1

Tags:

  Technical, Publication, Corporation, Centurylink, Centurylink corporation technical publication

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of CenturyLink Corporation Technical Publication ...

1 CenturyLink Corporation Technical Publication Telecommunications Equipment Installation Guidelines Copyright 1993, 1996, 1997, 1998, 1999, 2000, 2001, 2003, 2007, 2016 77350 CenturyLink Corporation Issue O All Rights Reserved July 2016 CenturyLink Tech Pub 77350 Issue N, July 2016 Notice NOTICE This document describes CenturyLink s requirements for Suppliers of Central Office Equipment (Inside Plant ISP) Installation Services (herein referred to as the Service Supplier). The information provided in this document includes workmanship guidelines, Technical requirements, and Supplier competency requirements. CenturyLink Corporation reserves the right to revise this document for any reason, including but not limited to, conformity with standards promulgated by various governmental or regulatory agencies; utilization of advances in the state of the Technical arts; or to reflect changes in the design of equipment, techniques, or procedures described or referred to herein.

2 Liability to anyone arising out of use or reliance upon any information set forth herein is expressly disclaimed, and no representation or warranties, expressed or implied, are made with respect to the accuracy or utility of any information set forth herein. This document is not to be construed as a suggestion to any manufacturer to modify or change any of its products, nor does this Publication represent any commitment by CenturyLink Corporation to purchase any specific products. Further, conformance to this Publication does not constitute a guarantee of a given supplier's equipment and/or its associated documentation. Future issues of Technical Publication 77350 will be announced to the industry at least 30 days prior to the issuance date. This notice, which will come through our standard customer notification channels via the Wholesale Markets Change Management Process (CMP), will allow the customer time to comment on the proposed revisions.

3 Ordering information for CenturyLink Publications can be obtained from the Reference Section of this document. If further information is required, please contact: Jeff Bostow Lead Process Analyst 100 CenturyLink Drive Monroe, LA 71203-2041 E-mail: Throughout this Publication , the term CenturyLink signifies CenturyLink Corporation . Notice CenturyLink Tech Pub 77350 Issue O, July 2016 COMMENTS on TP 77350 PLEASE SEND YOUR COMMENTS/SUGGESTIONS TO: CenturyLink Corporation Jeff Bostow Lead Process Analyst 100 CenturyLink Drive Monroe, LA 71203-2041 E-mail: Information from you helps us to improve our Publications. Please take a few moments to answer the following questions and return to the above address. Was this Publication valuable to you in u nderstanding the Technical parameters of our service? YES NO Was the information accurate and up-to-date?

4 YES NO Was the information easily understood? YES NO Were the contents logically sequenced? YES NO Were the tables and figures understandable YES NO and helpful? Were the pages legible? YES NO If you answered NO to any of the questions and/or if you have any other comments or suggestions, please explain: (Attach additional sheet, if necessary) Name Date Company Address Telephone Number E-Mail CenturyLink Tech Pub 77350 Table of Contents Issue O, July 2016 CONTENTS Chapter and Section Page 1.

5 Introduction .. 1- 1 General (Scope of Document) .. 1- 1 CenturyLink Quality Audits .. 1- 1 Quality Policy Statement .. 1- 1 Reason For Reissue .. 1- 1 Document Organization .. 1- 2 2. General Requirements General .. 2- 1 Facility Access and Security .. 2- 5 Facility Environmental Conditions, Upkeep, Storage, and Handling .. 2- 8 Environmental, Safety, and Health .. 2- 10 Electrostatic Discharge .. 2- 18 Fire Protection Policy .. 2- 18 Network Alarms .. 2- 21 Equipment Performance Tests .. 2- 24 Maintenance Window .. 2- 24 Wood Products and Wood for Use in Equipment Locations .. 2- 25 Letter of Deviation .. 2- 26 3. Assembly and Ironwork .. 3- 1 General Requirements .. 3- 1 Apparatus .. 3- 2 Appliance/Base and Utility Outlets and Permanently Mounted Power Strips .. 3- 2 Auxiliary Framing .. 3- 2 Bolts, Nuts, Screws, and Threaded Rods.

6 3- 3 Cable Racks .. 3- 4 AC Conduit .. 3- 6 Cotter Pins .. 3- 6 Earthquake Considerations .. 3- 6 Equipment Removal For Reuse or Retirement .. 3- 8 CenturyLink Tech Pub 77350 Table of Contents Issue O, July 2016 Chapter and Section - continued Page Fiber Optic Protective/Distribution Systems .. 3- 98 Frames, Bays, Cabinets, and Stands .. 3- 11 Framework and Ironwork Components .. 3- 16 Lighting Fixtures .. 3- 16 Rolling Ladders and Tracks .. 3- 16 Units of Equipment .. 3- 17 Antenna and associated Transmission Lines .. 3- 21 Earthquake Zone Map .. 3- 22 Alignment Tables .. 3- 22 Building Envelope Drilling Procedures .. 3- 23 Floor Anchors and Installation Instructions .. 3- 24 Floor Anchor Bolt Modification Procedures .. 3- 26 Floor Tile Punch Procedure .. 3- 27 Floor Tile Drilling With HEPA Vacuum Attachment.

7 3- 28 Floor Tile Drilling With Separate HEPA Vacuum That Is Not Attached To Tile 3- 29 Raised Floors .. 3- 29 Waterproof Floor .. 3- 29 Battery Containment .. 3- 30 4. Cable Holes, Penetrations, and Fire/Smoke Protection .. 4- 1 General Requirements .. 4- 1 Closure Labels .. 4- 2 Horizontal, Miscellaneous, and Vertical Penetrations .. 4- 3 Intumescent Fire Stop Examples .. 4- 3 Cable Hole/Penetration Designations .. 4- 4 Approved Materials .. 4- 4 Embargoing Blocked/Exhausted Cable Hole Penetrations .. 4- 4 5. Cabling, Forming, Running, and Securing .. 5- 1 General Requirements .. 5- 1 Cable Mining .. 5- 3 Bending and Forming .. 5- 5 Protection and Storage .. 5- 7 Securing and 5- 8 Power cables .. 5- 10 Grounding Conductors .. 5- 11 CenturyLink Tech Pub 77350 Table of Contents Issue O, July 2016 Chapter and Section - continued Page Cable Pile-up.

8 5- 12 Coaxial Cables .. 5- 13 Fiber Optic Cable .. 5- 13 Ribbon Cable .. 5- 18 Repair of Damaged Cables .. 5- 18 Spliced Cables, Splicing Systems, and Mated Connectable Cables .. 5- 18 Use of Nylon and Plastic Cable Ties .. 5- 19 Securing Tables .. 5- 20 Securing Figures .. 5- 22 6. Wiring .. 6- 1 General Requirements .. 6- 1 Fanned and Unsewn Forms .. 6- 1 Sewn Forms .. 6- 2 Protection .. 6- 2 Cable Tags .. 6- 2 7. Connecting .. 7- 1 General Requirements .. 7- 1 Coaxial Connections and Test/Turn-up Parameters .. 7- 1 Connectable Cables .. 7- 3 Crimp Compression Connectors, Splices, and Taps .. 7- 3 Quick Clip/Slotted Beam Connections .. 7- 5 Soldered Connections .. 7- 5 Solderless Wire Wrapped Connections .. 7- 5 Solderless Wire Wrapped Exhibits .. 7- 7 Fiber Optic Cable Connections .. 7- 11 8.

9 Equipment Designations .. 8- 1 General Requirements .. 8- 2 Color of Characters for Stamping and Labels .. 8- 3 Designation Conventions .. 8- 3 Connectors, Connectable Cables, and Fiber Optics (Singles, Duals, and Quads) .. 8- 4 Distributing and Protector Frames .. 8- 5 CenturyLink Tech Pub 77350 Table of Contents Issue O, July 2016 Chapter and Section - continued Page Drawings and Assignment Records .. 8- 6 AC Circuits .. 8- 6 Batteries and Battery Stands .. 8- 6 DC Breakers, Fuses, Switches, and Shunts .. 8- 7 DC Distribution Elements .. 8- 9 Conductors, Leads, Bonding/Grounding Points .. 8- 9 Mechanical Equipment and Rooms .. 8- 11 High Temperature Surfaces .. 8- 11 High Voltage Surfaces .. 8- 11 Rectifiers, Converters, Inverters, Power Supplies .. 8- 11 Bus bars and Ground Bars .. 8- 12 Rolling Ladders .. 8- 12 Cable Rack Systems.

10 8- 13 Marking Records / Drawings .. 8- 13 Miscellaneous stenciling and Font Size Tables .. 8- 13 Distributing Frame Exhibits .. 8- 16 Bay Equipment Labels .. 8- 17 Temporary Removal and Installation Tag .. 8- 19 Labels .. 8- 19 Collocation Decommission Cable Tag .. 8- 21 Fire Code Power Room Door Placard .. 8- 25 Alarm / OSS Testing Incompletion Tag .. 8- 26 Lock out/Tag out Tag .. 8- 27 Equipment Removal from Service 8- 28 Building Columns .. 8- 29 Equipment Hot Surface Tag .. 8- 30 NFPA Very Early Warning Fire Detection Alarm System .. 8- 30 CenturyLink Pair Gain Site WARNING 9. Power .. 9- 1 AC Circuits .. 9- 1 Primary & Secondary Distribution .. 9- 7 Battery Primary Conductors .. 9- 9 Bus Bars .. 9- 11 Cabinets .. 9- 12 Connecting .. 9- 12 CenturyLink Tech Pub 77350 Table of Contents Issue O, July 2016 Chapter and Section - continued Page Fuse Bays, BDFBs, BDCBB POWER BOARDs, 9- 15 Fuse Contact Preparation and Protection.


Related search queries