Example: confidence

CHAPTER 17 STRUCTURAL TESTS AND SPECIAL INSPECTIONS

CHAPTER 17 STRUCTURAL TESTS AND SPECIAL INSPECTIONSSECTION provisions of this CHAPTER shall apply toClass I buildings and shall govern the quality, workmanshipand requirements for materials covered. Materials of construc-tion and TESTS shall conform to the applicable standards listed inthis New building materials, equipment,appliances, systems or methods of construction not providedfor in this code, and any material of questioned suitability pro-posed for use in the construction of a building or structure, shallbe subjected to the TESTS prescribed in this CHAPTER and in theapproved rules to determine character, quality and limitationsof Used use of second-hand materials thatmeet the minimum requirements of this code for new materialsshall be following words and terms shall, for thepurposes of this CHAPTER and as used elsewhere in this code,have the meanings shown AGENCY/ SPECIAL and recognized agency or design professional act-ing as the approved agency regularly engaged in conductingtests or furnishing inspection services, when such agency hasbeen approved.

A statement of special inspections is not required for structures designed and constructed in accor-dance with the conventional construction provi-sions of Section 2308. 2. The statement of special inspections is permitted ... STRUCTURAL TESTS AND SPECIAL INSPECTIONS a

Tags:

  Tests, Testament, Special, Structural, Inspection, Structural tests and special inspections, Statement of special inspections

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of CHAPTER 17 STRUCTURAL TESTS AND SPECIAL INSPECTIONS

1 CHAPTER 17 STRUCTURAL TESTS AND SPECIAL INSPECTIONSSECTION provisions of this CHAPTER shall apply toClass I buildings and shall govern the quality, workmanshipand requirements for materials covered. Materials of construc-tion and TESTS shall conform to the applicable standards listed inthis New building materials, equipment,appliances, systems or methods of construction not providedfor in this code, and any material of questioned suitability pro-posed for use in the construction of a building or structure, shallbe subjected to the TESTS prescribed in this CHAPTER and in theapproved rules to determine character, quality and limitationsof Used use of second-hand materials thatmeet the minimum requirements of this code for new materialsshall be following words and terms shall, for thepurposes of this CHAPTER and as used elsewhere in this code,have the meanings shown AGENCY/ SPECIAL and recognized agency or design professional act-ing as the approved agency regularly engaged in conductingtests or furnishing inspection services, when such agency hasbeen approved.

2 SPECIAL inspectors shall be certified in accor-dance with the administrative provisions of theUniform Con-struction established and qualifiedperson, firm or corporation approved by the building officialpursuant to CHAPTER 17 of this OF certificate statingthat materials and products meet specified standards or thatwork was done in compliance with approved construction SEISMIC architectural,electrical and mechanical systems and their components thatrequire design in accordance with CHAPTER 13 of ASCE 7 andfor which the component importance factor,Ip, is greater than 1in accordance with Section of ASCE , load-bearing or lateralload-resisting assemblies consisting of materials assembledprior to installation in a building or structure or subjected tooperations such as heat treatment, thermal cutting, cold work-ing or reforming after manufacture and prior to installation in abuilding or structure. Materials produced in accordance withstandard specifications referenced by this code, such as rolledstructural steel shapes, steel-reinforcing bars, masonry unitsand wood STRUCTURAL panels shall not be considered fabricateditems.

3 inspection identification applied ona product by an approved agency containing the name of themanufacturer, the function and performance characteristics,and the name and identification of an approved agency thatindicates that the product or material has been inspected andevaluated by an approved agency (see Section and Label, Manufacturer s designation and Mark ). identification applied on a product by the manu-facturer that contains the name of the manufacturer, the func-tion and performance characteristics of the product or material,and the name and identification of an approved agency and thatindicates that the representative sample of the product or mate-rial has been tested and evaluated by an approved agency (seeSection and inspection certificate, Manufacturer sdesignation and Mark ).MAIN WIND-FORCE-RESISTING assem-blage of STRUCTURAL elements assigned to provide support andstability for the overall structure. The system generallyreceives wind loading from more than one S identificationapplied on a product by the manufacturer indicating that aproduct or material complies with a specified standard or set ofrules (see also inspection certificate, Label and Mark ).

4 Identification applied on a product by the manu-facturer indicating the name of the manufacturer and the func-tion of a product or material (see also inspection certificate, Label and Manufacturer s designation ). SPECIAL as herein required ofthe materials, installation, fabrication, erection or placement ofcomponents and connections requiring SPECIAL expertise toensure compliance with approved construction documents andreferenced standards (see Section 1704). SPECIAL inspection , full-timeobservation of work requiring SPECIAL inspection by anapproved SPECIAL inspector who is present in the area where thework is being inspection , part-time orintermittent observation of work requiring SPECIAL inspectionby an approved SPECIAL inspector who is present in the areawhere the work has been or is being performed and at the com-pletion of the or fibrous materials that are spray applied to pro-vide fire-resistant protection of the visual observation ofthe STRUCTURAL system by a registered design professional forgeneral conformance to the approved construction documentsat significant construction stages and at completion of thestructural system.

5 STRUCTURAL observation does not include orINTERNATIONAL BUILDING CODE 2006, NEW JERSEY :\data\CODES\STATE CODES\New Jersey\2006\NJ_Bldg_2006\Final VP_Chgo\ , April 18, 2007 8:11:58 AMColor profile: Generic CMYK printer profileComposite Default screenwaive the responsibility for the inspection required by theadministrative provisions of theUniform Construction Code( 5:23), Section 1704 or other sections of this Approved the request of the construc-tion official, an approved agency shall provide all informationas necessary for the construction official to determine that theagency meets the following approved agency shall be objec-tive and competent. The agency shall also disclose possibleconflicts of interest so that objectivity can be approved agency shall have ade-quate equipment to perform required TESTS . The equipmentshall be periodically approved agency shall employexperienced personnel educated in conducting, supervisingand evaluating TESTS and/or approved agency shall employpersonnel certified in accordance with the administrativeprovisions of theUniform Construction Codeto conduct,supervise and evaluate TESTS or Written material, appliance, equip-ment, system or method of construction meeting the require-ments of this code shall be approved in writing aftersatisfactory completion of the required TESTS and submission ofrequired test Approved any material, appliance, equip-ment, system or method of construction that has beenapproved, a record of such approval, including the conditionsand limitations of the approval.

6 Shall be kept on file in the build-ing official s office and shall be open to public inspection atappropriate information consisting of testreports conducted by an approved testing agency in accordancewith standards referenced in CHAPTER 35, or other such informa-tion as necessary, shall be provided for the building official todetermine that the material meets the applicable code Research and technicaldata shall be submitted to the building official to substanti-ate the proposed use of any material or assembly. If it isdetermined that the evidence submitted is satisfactory proofof performance for the use intended, the building officialshall approve the use of the material or assembly subject tothe requirements of this code. The costs, reports and investi-gations required under these provisions shall be paid by thepermit Research data, where neces-sary to assist in the approval of materials or assemblies notspecifically provided for in this code, shall consist of validresearch reports from approved materials or assemblies are requiredby this code to be labeled, such materials and assemblies shallbe labeled by an approved agency in accordance with Section1703.

7 Products and materials required to be labeled shall belabeled in accordance with the procedures set forth in through approved agency shall test a represen-tative sample of the product or material being labeled to therelevant standard or standards. The approved agency shallmaintain a record of the TESTS performed. The record shallprovide sufficient detail to verify compliance with the inspection and approvedagency shall periodically perform an inspection , whichshall be in-plant if necessary, of the product or material thatis to be labeled. The inspection shall verify that the labeledproduct or material is representative of the product or mate-rial Label label shall contain themanufacturer s or distributor s identification, model num-ber, serial number or definitive information describing theproduct or material s performance characteristics andapproved agency s Heretofore approved use of any mate-rial already fabricated or of any construction already erected,which conformed to requirements or approvals heretofore ineffect, shall be permitted to continue, if not detrimental to life,health or safety to the Evaluation and follow-up inspection components or other items regulated by this code arenot visible for inspection after completion of a prefabricatedassembly, the permit applicant shall submit a report of eachprefabricated assembly inaccordance with The report shall indicate the complete details of theassembly.

8 Including a description of the assembly and its com-ponents, the basis upon which the assembly is being evaluated,test results and similar information and other data as necessaryfor the building official to determine conformance to this a report shall be approved by the building Follow-up permit applicant shallprovide for SPECIAL INSPECTIONS of fabricated items in accor-dance with Section Test and inspection of necessarytest and inspection records shall be filed with the 1704 SPECIAL application is made for construction ofClass 1 buildings only as described in this section, the owner orthe person in responsible charge acting as the owner s agentshall employ one or more SPECIAL inspectors to provide inspec-tions during construction on the types of work listed under Sec-tion 1704. The SPECIAL inspector shall be a qualified person whoshall demonstrate competence, to the satisfaction of the build-ing official, for inspection of the particular type of constructionor operation requiring SPECIAL inspection .

9 These inspections308 INTERNATIONAL BUILDING CODE 2006, NEW JERSEY EDITIONSTRUCTURAL TESTS AND SPECIAL :\data\CODES\STATE CODES\New Jersey\2006\NJ_Bldg_2006\Final VP_Chgo\ , April 18, 2007 8:11:58 AMColor profile: Generic CMYK printer profileComposite Default screenare in addition to the INSPECTIONS specified in the administrativeprovisions of theUniform Construction Code( 5:23).Exceptions:1. SPECIAL INSPECTIONS are not required for work of aminor nature or as warranted by conditions in thejurisdiction as approved by the building SPECIAL INSPECTIONS are not required for building com-ponents unless the design involves the practice of pro-fessional engineering or architecture as defined byapplicable state statutes and regulations governingthe professional registration and certification of engi-neers or Unless otherwise required by the building official, SPECIAL INSPECTIONS are not required for occupanciesin Group R-3 and occupancies in Group U that areaccessory to a residential occupancy including, butnot limited to, those listed in Section Statement of SPECIAL permitapplicant shall submit a statement of SPECIAL inspectionsprepared by the registered design professional in responsi-ble charge in accordance with the administrative provisionsof theUniform Construction Code( 5.)

10 23) as a con-dition for permit issuance. This statement shall be in accor-dance with Section :1. A statement of SPECIAL INSPECTIONS is not requiredfor structures designed and constructed in accor-dance with the conventional construction provi-sions of Section The statement of SPECIAL INSPECTIONS is permittedto be prepared by a qualified person approved bythe building official for construction not designedby a registered design Report inspectors shallkeep records of INSPECTIONS . The SPECIAL inspector shall fur-nish inspection reports to the construction official, and tothe person in responsible charge in accordance 5 (c). Reports shall indicate that workinspected was done in conformance to approved construc-tion documents. Discrepancies shall be brought to theimmediate attention of the contractor for correction. If thediscrepancies are not corrected, the discrepancies shall bebrought to the attention of the building official and to theregistered design professional in responsible charge prior tothe completion of that phase of the work.