CHAPTER 6 TYPES OF CONSTRUCTIONSECTION provisions of this CHAPTER shall control theclassification of buildings as to type of 602 CONSTRUCTION and structures erected or to beerected, altered or extended in height or area shall be classifiedin one of the five CONSTRUCTION TYPES defined in Sections The building elements shall have afire-resis-tance ratingnot less than that specified in Table 601 and exte-rior walls shall have afire-resistance ratingnot less than thatspecified in Table 602. Where required to have afire-resistanceratingby Table 601, building elements shall comply with theapplicable provisions of Section The protection of open-ings, ducts and air transfer openings in building elements shallnot be required unless required by other provisions of this Minimum building or portionthereof shall not be required to conform to the details of atype of CONSTRUCTION higher than that type which meets theminimum requirements based on occupancy even thoughcertain features of such a building actually conform to ahigher type of TYPES I and I and II CONSTRUCTION are thosetypes of CONSTRUCTION in which the building elements listed inTable 601 are of noncombustible materials, except as perm

details of Type IV construction shall comply with the provi-sions of this section. Fire-retardant-treated wood framing complying with Section 2303.2 …

Tags:

  Types, Chapter, Construction, Fire, Chapter 6 types of construction

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of CHAPTER 6 TYPES OF CONSTRUCTION - ecodes.biz

1 CHAPTER 6 TYPES OF CONSTRUCTIONSECTION provisions of this CHAPTER shall control theclassification of buildings as to type of 602 CONSTRUCTION and structures erected or to beerected, altered or extended in height or area shall be classifiedin one of the five CONSTRUCTION TYPES defined in Sections The building elements shall have afire-resis-tance ratingnot less than that specified in Table 601 and exte-rior walls shall have afire-resistance ratingnot less than thatspecified in Table 602. Where required to have afire-resistanceratingby Table 601, building elements shall comply with theapplicable provisions of Section The protection of open-ings, ducts and air transfer openings in building elements shallnot be required unless required by other provisions of this Minimum building or portionthereof shall not be required to conform to the details of atype of CONSTRUCTION higher than that type which meets theminimum requirements based on occupancy even thoughcertain features of such a building actually conform to ahigher type of TYPES I and I and II CONSTRUCTION are thosetypes of CONSTRUCTION in which the building elements listed inTable 601 are of noncombustible materials.

2 Except as permittedin Section 603 and elsewhere in this Type III CONSTRUCTION is that type of construc-tion in which the exterior walls are of noncombustible materi-als and the interior building elements are of any materialpermitted by this woodframingcomplying with Section shall be permitted withinexte-rior wallassemblies of a 2-hour rating or Type IV CONSTRUCTION (Heavy Timber, HT) isthat type of CONSTRUCTION in which the exterior walls are ofnoncombustible materials and the interior building elementsare of solid or laminated wood without concealed spaces. The2010 OREGON STRUCTURAL SPECIALTY CODE95 TABLE 601 fire -RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (hours)BUILDING ELEMENTTYPE ITYPE IITYPE IIITYPE IVTYPE VABAdBAdBHTAdBPrimary structural frameg(see Section 202)3a2a10 1 0HT1 0 Bearing wallsExteriorf, gInterior33a22a1100212021/HT1100 Nonbearing walls and partitionsExteriorSee Table 602 Nonbearing walls and partitionsInteriore000000 See Section CONSTRUCTION and secondarymembers (see Section 202)2 210 1 0HT1 0 Roof CONSTRUCTION and secondarymembers (see Section 202)11/2b1b, c1b, c0c1b, c0HT1b, c0 For SI: 1 foot = Roof supports.

3 fire -resistance ratings of primary structural frame and bearing walls are permitted to be reduced by 1 hour where supporting a roof Except in Group F-1, H, M and S-1 occupancies, fire protection of structural members shall not be required, including protection of roof framing anddeckingwhere every part of the roof CONSTRUCTION is 20 feet or more above any floor immediately below. fire -retardant-treated wood members shall be allowed to be usedfor such unprotected In all occupancies, heavy timber shall be allowed where a 1-hour or less fire -resistance rating is An approved automatic sprinkler system in accordance with Section shall be allowed to be substituted for 1-hour fire -resistance-ratedconstruction, pro-vided such system is not otherwise required by other provisions of the code or used for an allowable area increase in accordance with Section or anallowableheight increase in accordance with Section The 1-hour substitution for the fire resistance of exterior walls shall not be Not less than the fire -resistance rating required by other sections of this Not less than the fire -resistance rating based on fire separation distance (see Table 602).

4 G. Not less than the fire -resistance rating as referenced in Section 1M:\data\CODES\STATE CODES\Oregon\2010\Structural Specialty_Building\Final VP\ , January 08, 2010 12:12:18 PMColor profile: Generic CMYK printer profileComposite Default screendetails of Type IV CONSTRUCTION shall comply with the provi-sions of this woodframingcomplying with Section shall be permitted within exte-rior wall assemblies with a 2-hour rating or less. Minimumsolid sawn nominal dimensions are required for structures builtusing Type IV CONSTRUCTION (HT). For glued-laminated mem-bers the equivalent net finished width and depths correspond-ing to the minimum nominal width and depths of solid sawnlumber are required as specified in Table columns shall be sawn or gluedlaminated and shall not be less than 8 inches (203 mm),nominal, in any dimension where supporting floor loads andnot less than 6 inches (152 mm) nominal in width and notless than 8 inches (203 mm) nominal in depth where sup-porting roof and ceiling loads only.

5 Columns shall be con-tinuous or superimposed and connected in Floor beams and girders shall be ofsawn or glued-laminated timber and shall be not less than 6inches (152 mm) nominal in width and not less than 10inches (254 mm) nominal in depth. Framed sawn orglued-laminated timber arches, which spring from the floorline and support floor loads, shall be not less than 8 inches(203 mm) nominal in any dimension. Framed timber trussessupporting floor loads shall have members of not less than 8inches (203 mm) nominal in any Roof or glued-laminatedarches for roof CONSTRUCTION , which spring from the floorline or from grade and do not support floor loads, shall havemembers not less than 6 inches (152 mm) nominal in widthand have not less than 8 inches (203 mm) nominal in depthfor the lower half of the height and not less than 6 inches(152 mm) nominal in depth for the upper half.

6 Framed orglued-laminated arches for roof CONSTRUCTION that springfrom the top of walls or wall abutments, framed timbertrusses and other roof framing, which do not support floorloads, shall have members not less than 4 inches (102 mm)nominal in width and not less than 6 inches (152 mm) nomi-nal in depth. Spaced members shall be permitted to be com-posed of two or more pieces not less than 3 inches (76 mm)nominal in thickness where blocked solidly throughouttheir intervening spaces or where spaces are tightly closedby a continuous wood cover plate of not less than 2 inches(51 mm) nominal in thickness secured to the underside ofthe members. Splice plates shall be not less than 3 inches (76mm) nominal in thickness. Where protected byapprovedautomatic sprinklers under the roof deck, framing membersshall be not less than 3 inches (76 mm) nominal in OREGON STRUCTURAL SPECIALTY CODETYPES OF CONSTRUCTIONTABLE 602 fire -RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON fire SEPARATION DISTANCEa, eFIRE SEPARATION DISTANCE = X(feet)TYPE OF CONSTRUCTIONOCCUPANCYGROUP HfOCCUPANCYGROUP F-1, M, S-1gOCCUPANCYGROUP A, B, E, F-2, I, R, S-2g,UbX< 5cAll3215 X<10 IAOthers32211110 X<30IA, IBIIB, VBOthers2111011d01dX 30 All000 For SI.

7 1 foot = Load-bearing exterior walls shall also comply with the fire -resistance rating requirements of Table For special requirements for Group U occupancies, see Section See Section for party Open parking garages complying with Section 406 shall not be required to have a fire -resistance The fire -resistance rating of an exterior wall is determined based upon the fire separation distance of the exterior wall and the story in which the wall is For special requirements for Group H occupancies, see Section For special requirements for Group S aircraft hangars, see Section MEMBER SIZEMINIMUM NOMINAL SOLID SAWN SIZEMINIMUM GLUED-LAMINATED NET SIZEW idth, inchDepth, inchWidth, inchDepth, inch8863/481/46105101/268581/4665646367/ 8 For SI: 1 inch = :\data\CODES\STATE CODES\Oregon\2010\Structural Specialty_Building\Final VP\ , January 08, 2010 12:12:19 PMColor profile: Generic CMYK printer profileComposite Default shall be without concealed floors shall be of sawn or glued-laminated planks,splined or tongue-and-groove, of not less than 3 inches (76mm) nominal in thickness covered with 1-inch (25 mm)nominal dimension tongue-and-groove flooring, laid cross-wise or diagonally, or ( mm) particleboard orplanks not less than 4 inches (102 mm) nominal in width seton edge close together and well spiked and covered with1-inch (25 mm) nominal dimension flooring or15/32-inch(12 mm) wood structural panel or ( mm)particleboard.

8 The lumber shall be laid so that no continu-ous line of joints will occur except at points of shall not extend closer than inch ( mm) towalls. Such ( mm) space shall be covered by amolding fastened to the wall and so arranged that it will notobstruct the swelling or shrinkage movements of the of masonry walls under the floor shall be permit-ted to be used in place of shall be without concealed spaces andwood roof decks shall be sawn or glued laminated, splinedor tongue-and-groove plank, not less than 2 inches (51 mm)nominal in thickness, 11/8-inch-thick (32 mm) wood struc-tural panel (exterior glue), or of planks not less than 3 inches(76 mm) nominal in width, set on edge close together andlaid as required for floors. Other TYPES of decking shall bepermitted to be used if providing equivalentfire resistanceand structural shall be of solid wood con-struction formed by not less than two layers of 1-inch (25mm) matched boards or laminated CONSTRUCTION 4 inches(102 mm) thick, or of 1-hour fire -resistance-rated Exterior structural a horizontalseparation of 20 feet (6096 mm)

9 Or more is provided, woodcolumns and arches conforming to heavy timber sizes shallbe permitted to be used Type V CONSTRUCTION is that type of constructionin which the structural elements,exterior wallsand interiorwalls are of any materials permitted by this 603 COMBUSTIBLE MATERIAL INTYPE I AND II Allowable materials shall bepermitted in buildings of Type I or II CONSTRUCTION in the follow-ing applications and in accordance with Sections :1. Thermal and acoustical insulation, other than foamplastics, having aflame spread indexof not more :1. Insulation placed between two layers ofnoncombustible materials without an interven-ing airspace shall be allowed to have aflamespread indexof not more than Insulation installed between a finished floorand solid decking without intervening airspaceshall be allowed to have aflame spread indexofnot more than Foam plastics in accordance with CHAPTER Roof coverings that have an A, B or C floor finishand floor covering materialsinstalled in accordance with Section Millwork such as doors, door frames, window sashesand wall and ceiling finishesinstalled in accor-dance with Sections 801 and in accordance with Section Where not installed over 15 feet (4572 mm)

10 Abovegrade, show windows, nailing or furring strips andwooden bulkheads below show windows, includingtheir frames, aprons and show Finish flooring installed in accordance with Partitions dividing portions of stores, offices or similarplaces occupied by one tenant only and that do notestablish acorridorserving anoccupant loadof 30 ormore shall be permitted to be constructed offire-retar-dant-treated wood, 1-hour fire -resistance-rated con-struction or of wood panels or similar light constructionup to 6 feet (1829 mm) in Stages and platforms constructed in accordance withSections and , Combustibleexterior wall coverings, balconies andsimilar projections and bay or oriel windows in accor-dance with CHAPTER Blocking such as for handrails, millwork, cabinets andwindow and door Light-transmitting plastics as permitted by CHAPTER Mastics and caulking materials applied to provide flex-ible seals between components ofexterior Exterior plastic veneer installed in accordance withSection Nailing or furring strips as permitted by Section Heavy timber as permitted by Note c to Table 601 andSections and Aggregates, component materials and admixtures aspermitted by Section Sprayed fire -resistant materials and intumescent andmastic fire -resistant coatings.