12V12V, 24V12V12V, 24V12V, 24V, 36V12V, 24V, 36V, 48V12V12V, 24V12V, 24V, 36V66, 61010,1010, 10, 1010, 10, 10, 101515, 1515, 15, 156 amps12 amps10 amps20 amps30 amps40 amps15 amps30 amps45 ampsPro XLDual Pro XLPro SE Dual Pro SEThree Bank Pro SEFour Bank Pro SEPro ChargerDual Pro ChargerThree Bank Pro ChargerModel NameTotal OutputAmps Per BankBatterySystem# 701162 CHARGING SYSTEMS INTERNATIONALINSTALLATION AND OPERATING INSTRUCTIONSFOR THE FOLLOWING BATTERY CHARGING SYSTEMS :IMPORTANT NOTICEP lease save and read all safety , operating and installation instructions before installing or applying AC power to your CHARGING SYSTEMS INTERNATIONAL on-board battery chargingsystem. Please contact CHARGING SYSTEMS INTERNATIONAL with any product, installation, or service questions at SYSTEMS INTERNATIONAL has been manufacturing waterproof, on-board batterycharging SYSTEMS since 1989. Our CHARGING SYSTEMS are designed and built tough to withstand intense vibration, extreme temperature variations and submersion without damaging the SYSTEMS use temperature compensation in order to fullycharge a battery in hot or cold environments and are controlled by microprocessorsin order to assure precise control over each totally independent CHARGING of our chargers have true reverse polarity protection and shut off completely after each charge OF CONTENTSS afety Instructions.

2 CHARGING SYSTEMS INTERNATIONAL INSTALLATION AND OPERATING INSTRUCTIONS FOR THE FOLLOWING BATTERY CHARGING SYSTEMS: IMPORTANT NOTICE Please save and read all safety, operating and …

Tags:

  International, System, Safety, Charging, Charging systems international

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of CHARGING SYSTEMS INTERNATIONAL - …

1 12V12V, 24V12V12V, 24V12V, 24V, 36V12V, 24V, 36V, 48V12V12V, 24V12V, 24V, 36V66, 61010,1010, 10, 1010, 10, 10, 101515, 1515, 15, 156 amps12 amps10 amps20 amps30 amps40 amps15 amps30 amps45 ampsPro XLDual Pro XLPro SE Dual Pro SEThree Bank Pro SEFour Bank Pro SEPro ChargerDual Pro ChargerThree Bank Pro ChargerModel NameTotal OutputAmps Per BankBatterySystem# 701162 CHARGING SYSTEMS INTERNATIONALINSTALLATION AND OPERATING INSTRUCTIONSFOR THE FOLLOWING BATTERY CHARGING SYSTEMS :IMPORTANT NOTICEP lease save and read all safety , operating and installation instructions before installing or applying AC power to your CHARGING SYSTEMS INTERNATIONAL on-board battery chargingsystem. Please contact CHARGING SYSTEMS INTERNATIONAL with any product, installation, or service questions at SYSTEMS INTERNATIONAL has been manufacturing waterproof, on-board batterycharging SYSTEMS since 1989. Our CHARGING SYSTEMS are designed and built tough to withstand intense vibration, extreme temperature variations and submersion without damaging the SYSTEMS use temperature compensation in order to fullycharge a battery in hot or cold environments and are controlled by microprocessorsin order to assure precise control over each totally independent CHARGING of our chargers have true reverse polarity protection and shut off completely after each charge OF CONTENTSS afety Instructions.

2 Page 2-4 Product Summary ..Page 4 Installation Instructions ..Page 5-6 Trouble Shooting ..Page 6-7 Warranty Information ..Page 7 IMPORTANT safety INSTRUCTIONSSAVE THESE INSTRUCTIONS-This manual contains important safety and operatinginstructions for battery charger models: Pro XL, Dual Pro XL, Pro SE, Dual Pro SE, Three Bank Pro SE, Four Bank Pro SE, Pro Charger, Dual Pro Charger, Three Bank of attachments not recommended or sold by CHARGING SYSTEMS INTERNATIONAL mayresult in a risk of fire, electrical shock, or injury to reduce risk of damage to electric plug and cord, pull by plug rather than cord when disconnecting OFBATTERYMODELS AMPS/BANKBANKS SYSTEMPRO XL 6112 DUAL PRO XL6212/24 PRO SE10112 DUAL PRO SE10212/24 THREE BANK PRO SE10312/24/36 FOUR BANK PRO SE10412/24/36/48 PRO CHARGER15112 DUAL PRO CHARGER 15212/24 THREE BANK PRO CHARGER15312/24/36 When using an extension cord, make sure:1.

3 That pins on plug of extension cord are the same number, size and shape as those of the charger plug;2. That extension cord is properly wired and in good electrical condition;3. That wire size is large enough for ac ampere rating of not operate charger with damaged cord or plug - replace the cord or plug not operate charger if it has received a sharp blow, been dropped or otherwise damagedin any way; contact CHARGING SYSTEMS not disassemble charger; contact the factory when service or repair is reassembly may result in risk of electrical shock or reduce risk of electric shock, unplug charger from outlet before attempting any maintenance or OF EXPLOSIVE WORKING IN THE VICINITY OF A LEAD-ACID BATTERY IS generate explosive gases during normal battery operation. For thisreason, it is of utmost importance that each time before using your charger, youread this manual and follow the instructions To reduce risk of battery explosion, follow these instructions and those published by battery manufacturer and manufacturer of any equipment you intend to use in vicinity of battery.

4 Review cautionary markings on these products and on PRECAUTIONSS omeone should be within range of your voice or close enough to come to your aid whenyou work near a lead-acid plenty of fresh water and soap nearby in case battery acid contacts skin, clothingor complete eye protection and clothing protection. Avoid touching eyes whileworking near battery acid contacts skin or clothing, wash immediately with soap and water. If acidenters eye, immediately flood eye with running cold water for at least 10 minutes and getmedical attention smoke or allow a spark or flame in vicinity of battery or extra cautious to reduce risk of dropping a metal tool onto battery. It might spark orshort-circuit battery or other electrical part that may cause personal metal items such as rings, bracelets, necklaces, and watches when working with a lead-acid battery. A lead-acid battery can produce a short-circuit currenthigh enough to weld a ring or the like to metal, causing a severe charger for CHARGING a LEAD-ACID (lead acid, sealed lead acid, gel cell and AGM) battery only.

5 It is not intended to supply power to a low voltage electrical system other thanin a starter-motor application. Do not use battery charger for CHARGING dry-cell batteries34that are commonly used with home appliances. These batteries may burst and cause injury topersons and damage to charge a frozen TO CHARGEIf it is necessary to remove the battery to charge, always remove grounded terminal frombattery first. Make sure all accessories are off, so as not to cause an sure area around battery is well ventilated while batteries are being charged. Gasfumes can be forcefully blown away by using a piece of cardboard or other nonmetallicmaterial, as a battery terminals. Be careful to keep corrosion from coming in contact with distilled water in each cell until battery acid reaches level specified by battery manufacturer. This helps purge excessive gas from cells. Do not overfill. For a batterywithout cell caps, carefully follow manufacturer s recharging all battery manufacturers specific precautions such as removing or not removing cellcaps while CHARGING and recommended rates of cords should be industrial grade/heavy duty approved and grounded.

6 Checkextension cord before use for damage, bent prongs and cuts. Replace if make your extension cord connection on the charger side first. After connecting theextension cord to the charger then proceed to plug the extension cord to a nearby 120 VACGFCI protected (Ground Fault Circuit Interrupt) remove the extension cord from the 120 VAC outlet first when CHARGING is completedfollowed by unplugging the SUMMARYG eneral Operation:Use the following guidelines in this manual to install your fully automatic CHARGING SystemsInternational battery CHARGING that your charger and batteries are properly vented. Connect your extension cordwith no AC Power present to the battery charger and proceed to plug your extension cord inat a nearby 120 VAC you plug in your CHARGING SYSTEMS INTERNATIONAL battery CHARGING system , your batterieswill be simultaneously and independently charged to 100%. Unlike SYSTEMS that utilize onelarge charger to attempt to charge multiple batteries, your system utilizes a totally independentbattery charger for each battery.

7 Each CHARGING bank will turn itself completely off once thebattery is charged and then monitor and maintain the battery recommend that you leave your system plugged in to reduce sulfate build-up and to allowyour CHARGING SYSTEMS INTERNATIONAL CHARGING system to keep your batteries fully maintainedand ready to perform at their CHARGING Bank IndicationsWhen your battery CHARGING system is activated, each bank provides CHARGING informationutilizing five red LED indicators and one green LED five red LEDs enable you to track the progress of the charge cycle on each battery asthe voltage rises.(see chart on next page)INSTALLATION INSTRUCTIONSAll CHARGING SYSTEMS INTERNATIONAL battery CHARGING SYSTEMS are designed to bepermanently mounted and have no mounting not make any electrical connections to the power supply (AC) or to a battery (DC)until the mounting process has been for fit and appropriate thickness of mounting area.

8 It is recommended that youchoose a flat surface. If mounting the charger in a boat please choose a surface as highabove the water level as possible. If a compartment wall is chosen, make certain itsstrength is the mounting flanges of the charger to mark locations for starter holes. Drill a 1/16 inch hole at each marked location. Then, utilize all stainless steel screws which havebeen provided and install the charger securely being cautious not to over tighten thescrews. Silicon sealer should be used to secure and waterproof the screw making any connections, prepare batteries as follows:(a) With caps securely in place, thoroughly clean the case and posts with a solution of baking soda and water. Be careful not to allow any soda to get inside the case.(b) All posts, terminals and connectors should be cleaned to a shiny bright finish, usinga wire brush or sand paper. This should be done periodically to assure NOTICEThe mounting bracket of the system containskeyholes that are designed so that somescrews can be started before putting thecharger into place.

9 The keyhole locations formounting your charger vary depending onwhich model you own. On the XL and SEmodels the mounting flanges run horizontalinstead of CHARGING PHASE 5 RED LED SABOVE VOLTS 4 RED LED SABOVE VOLTS 3 RED LED SBATTERY 80% CHARGED 2 RED LED SFINAL CHARGE PHASE 1 RED LEDCHARGE CURRENT OFF-MONITORING 1 GREEN LED6 Each charge cable assembly is equipped with a temperature sensor located at thejunction of each set of ring terminals. Attempts to lengthen or shorten the cables couldpartially disable the charger. Therefore, we recommend that you do not make anyadjustments without first consulting the your cables from the charger to your batteries, being cautious to avoid sharpobjects and use the supplied wire ties to hold them neatly in connect the red charger ring terminals to the positive battery posts and theblack charger ring terminals to the negative battery posts as shown addition, your CHARGING system is supplied with an AC plug receptacle designed tohold the power cord plug when it is not being used.

10 Locate a convenient site for thereceptacle and attach it using the four smaller stainless steel a heavy duty approved extension cord to the power cord of your chargerand then plug the extension cord in to a nearby 120 VAC GFI protected (Ground FaultCircuit Interrupt) should now observe red LED indications on each bank of the charger representingeach individual battery being charged. The voltage of each battery will reflect the numberof LED indicators illuminated. (See Product Summary)When CHARGING is complete, remove the extension cord from the 120 VAC outlet first andthen unplug the SHOOTINGPROBLEM: No LED indicators illuminate in any of the charger Sequence:Check the AC power supply from its source through all connecting points up to thecharger by using a meter or test light to confirm that current is being delivered to : One red LED Sequence:With the AC power supply cord unplugged, check the ring terminals for correct polarity(Red to positive or +) and (Black to negative or -).