Data SheetCitrix ADC Hardware PlatformsEnabling high performance application delivery with Hardware appliances and multi-tenant support Citrix Application Delivery Controller (ADC) is the most comprehensive application delivery and load balancing solution for multi-cloud environments. Because its software and Hardware form factors are all built on a single code base, Citrix ADC provides operational and feature consistency with comprehensive security for monolithic and microservices-based applications on-premises and in the pooled capacity licensing, you can easily move capacity across Citrix ADC form factors, clouds, and geographies to meet growing demand with no Application Delivery Management (ADM)

feature consistency with comprehensive security for monolithic and microservices-based applications on-premises and in the cloud. With pooled capacity licensing, you can easily move ... Width EIA 310-D, IEC 60297, DIN 41494 SC48D rack width with mounting brackets Depth 71.1 cm (28 in) 71.1 cm (28 in) 71.1 cm (28 in) ...

Tags:

  Security, Rack

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Citrix ADC Hardware Platforms

1 Data SheetCitrix ADC Hardware PlatformsEnabling high performance application delivery with Hardware appliances and multi-tenant support Citrix Application Delivery Controller (ADC) is the most comprehensive application delivery and load balancing solution for multi-cloud environments. Because its software and Hardware form factors are all built on a single code base, Citrix ADC provides operational and feature consistency with comprehensive security for monolithic and microservices-based applications on-premises and in the pooled capacity licensing, you can easily move capacity across Citrix ADC form factors, clouds, and geographies to meet growing demand with no Application Delivery Management (ADM)

2 Helps you achieve holistic visibility, management, and troubleshooting for your entire Citrix ADC fleet through a single, easy to use ADC Hardware PlatformsCitrix ADC MPXC itrix ADC MPX is a physical appliance that provides powerful Hardware -based application delivery and load balancing with options for high performance web application security and SSL offload ADC SDXC itrix ADC SDX introduces fully isolated multi-tenant support on a single appliance for application workloads and groups. Deploying multiple virtual instances of Citrix ADC on one Hardware appliance allows for the consolidation of multiple load balancers and application ADC FIPS PlatformsCitrix ADC offers specific physical and virtual Platforms with FIPS 140-2 compliance to meet the strict compliance mandates of high security businesses and more about the specific Citrix ADC FIPS Platforms by visiting the Citrix ADC FIPS Platforms data | Citrix ADC Hardware Platforms2 Citrix ADC PlatformMPX/SDX 26200-100 GMPX/SDX 26160-100 GMPX/SDX 26100-100 GAttributesMemory256 GB256 GB256 GBEthernet Ports18x 100GE QSFP288x 100GE QSFP288x 100GE QSFP28

3 Transceivers Support50GE/100GE QSFP28: SR4; 40GE QSFP+: SR4; 25GE SFP28: SR (Adapter required); 10GE SFP+: SR, LR (Adapter required)RAID SupportYesYesYesPay-as-you-grow & Burst Pack License Upgrades-Upgrade option to MPX/SDX 26200-100 GUpgrade option to MPX/SDX 26200, 160-100 GPerformanceSystem Throughput (Gbps) [L4/L7 Throughput]200160100L4/L7 HTTP Requests/sec5,500,0004,200,0003,200,000 SSL Transactions/sec (2K Key Certificates)2125,000110,00066,000 ECDHE Transactions/sec58,00050,00030,000 SSL Throughput (Gbps)604836 Compression Throughput (Gbps)181512 ICA Proxy/SSL VPN Concurrent Users20,00020,00020,000 Included Instances, Maximum Instances (on SDX Platforms )

4 115, 11570, 11520, 115 Mechanical, Environmental, and RegulatoryPower Supplies222 Input Voltage, Frequency Range100-240 VAC full range, 50-60 Hz100-240 VAC full range, 50-60 Hz100-240 VAC full range, 50-60 HzOptional DC Power SupplyYesYesYesMax Power Supply1000W1000W1000 WTypical, Max Power Consumption429W, 556W429W, 556W429W, 556 WWeight (lbs)484848 Height2U2U2 UWidthEIA 310-D, IEC 60297, DIN 41494 SC48D rack width with mounting cm (28 in) cm (28 in) cm (28 in)Operating Temperature0-45 C (32-113 F)0-45 C (32-113 F)0-45 C (32-113 F)Allowed Relative Humidity5%-95%, Non-condensing5%-95%, Non-condensing5%-95%, Non-condensingSafety CertificationsIEC/EN/UL/CSA/AS/NZS 62368-1 and 60950-1 Electromagnetic Emissions Certifications & Susceptibility StandardUS (FCC (Part 15 Class A)), Canada (ICES-003) EU (CE (EN 55032/55024)), Australia (RCM),Japan (VCCI), Korea (KCC), Taiwan (BSMI), China (CCC), India (BIS), Russia (EAC),Saudi Arabia (CITC), Brazil (Anatel), South Africa (ICASA), Mexico (NOM), Egypt (NTRA), Israel (MoC)Regulatory ComplianceRoHS, WEEE, REACHC itrix Compliance Regulatory Model2U1P1D2U1P1D2U1P1D1.

5 Published Ethernet interfaces compliant per 2. Performance varies depending on ciphers deployed. Contact your Citrix sales representative for | Citrix ADC Hardware Platforms3 Citrix ADC PlatformMPX/SDX 26200-50 SMPX/SDX 26160-50 SMPX/SDX 26100-50 SAttributesMemory256 GB256 GB256 GBEthernet Ports14x 50GE QSFP28; 16x 25GE SFP28 Transceivers Support50GE QSFP28 Port: 50GE/100GE QSFP28: SR4; 40GE QSFP+: SR4; 25GE SFP28: SR (Adapter required); 10GE SFP+: SR, LR (Adapter required) 25GE SFP28 Port: 25GE SFP28: SR; 10GE SFP+: SR, LRRAID SupportYesYesYesPay-as-you-grow & Burst Pack License Upgrades-Upgrade option to MPX/SDX 26200-50 SUpgrade option to MPX/SDX 26200, 160-50 SPerformanceSystem Throughput (Gbps) [L4/L7 Throughput]200160100L4/L7 HTTP Requests/sec6,500,0005,500,0004,500,000 SSL Transactions/sec (2K Key Certificates)2522,000358,000283,000 ECDHE Transactions/sec230,000165,000120,000 SSL Throughput (Gbps)12010080 Compression Throughput (Gbps)221613 ICA Proxy/SSL VPN Concurrent Users20,00020,00020,000 Included Instances, Maximum Instances (on SDX Platforms )

6 115, 11570, 11520, 115 Mechanical, Environmental, and RegulatoryPower Supplies222 Input Voltage, Frequency Range100-240 VAC full range, 50-60 Hz100-240 VAC full range, 50-60 Hz100-240 VAC full range, 50-60 HzOptional DC Power SupplyNoNoNoMax Power Supply1200W1200W1200 WTypical, Max Power Consumption670W, 809W670W, 809W670W, 809 WWeight (lbs)484848 Height2U2U2 UWidthEIA 310-D, IEC 60297, DIN 41494 SC48D rack width with mounting cm (28 in) cm (28 in) cm (28 in)Operating Temperature0-45 C (32-113 F)0-45 C (32-113 F)0-45 C (32-113 F)Allowed Relative Humidity5%-95%, Non-condensing5%-95%, Non-condensing5%-95%, Non-condensingSafety CertificationsIEC/EN/UL/CSA/AS/NZS 62368-1 and 60950-1 Electromagnetic Emissions Certifications & Susceptibility StandardUS (FCC (Part 15 Class A)), Canada (ICES-003) EU (CE (EN 55032/55024)), Australia (RCM),Japan (VCCI), Korea (KCC), Taiwan (BSMI), China (CCC), India (BIS), Russia (EAC),Saudi Arabia (CITC), Brazil (Anatel), South Africa (ICASA), Mexico (NOM), Egypt (NTRA), Israel (MoC)Regulatory ComplianceRoHS, WEEE, REACHC itrix Compliance Regulatory Model2U1P2A2U1P2A2U1P2A1.

7 Published Ethernet interfaces compliant per 2. Performance varies depending on ciphers deployed. Contact your Citrix sales representative for | Citrix ADC Hardware Platforms4 Citrix ADC PlatformMPX 26200T-100 GMPX 26160T-100 GMPX 26100T-100 GAttributesMemory256 GB256 GB256 GBEthernet Ports18x 100GE QSFP288x 100GE QSFP288x 100GE QSFP28 Transceivers Support50GE/100GE QSFP28: SR4; 40GE QSFP+: SR4; 25GE SFP28: SR (Adapter required); 10GE SFP+: SR, LR (Adapter required)RAID SupportYesYesYesPay-as-you-grow & Burst Pack License Upgrades-Upgrade option to MPX 26200T-100 GUpgrade option to MPX 26200T, 160T-100 GPerformanceSystem Throughput (Gbps) [L4/L7 Throughput]200160100L4/L7 HTTP Requests/sec5,500,0004,200,0003,200,000 SSL Transactions/sec (2K Key Certificates)2N/AN/AN/AECDHE Transactions/sec3N/AN/AN/ASSL Throughput (Gbps)N/AN/AN/ACompression Throughput (Gbps)181512 ICA Proxy/SSL VPN Concurrent Users20,00020,00020,000 Included Instances, Maximum Instances (on SDX Platforms )

8 N/AN/AN/AMechanical, Environmental, and RegulatoryPower Supplies222 Input Voltage, Frequency Range100-240 VAC full range, 50-60 Hz100-240 VAC full range, 50-60 Hz100-240 VAC full range, 50-60 HzOptional DC Power SupplyYesYesYesMax Power Supply1000W1000W1000 WTypical, Max Power Consumption332W, 454W332W, 454W332W, 454 WWeight (lbs)484848 Height2U2U2 UWidthEIA 310-D, IEC 60297, DIN 41494 SC48D rack width with mounting cm (28 in) cm (28 in) cm (28 in)Operating Temperature0-45 C (32-113 F)0-45 C (32-113 F)0-45 C (32-113 F)Allowed Relative Humidity5%-95%, Non-condensing5%-95%, Non-condensing5%-95%, Non-condensingSafety CertificationsIEC/EN/UL/CSA/AS/NZS 62368-1 and 60950-1 Electromagnetic Emissions Certifications & Susceptibility StandardUS (FCC (Part 15 Class A)), Canada (ICES-003) EU (CE (EN 55032/55024)), Australia (RCM),Japan (VCCI), Korea (KCC), Taiwan (BSMI), China (CCC), India (BIS), Russia (EAC),Saudi Arabia (CITC), Brazil (Anatel), South Africa (ICASA), Mexico (NOM), Egypt (NTRA), Israel (MoC)Regulatory ComplianceRoHS, WEEE, REACHC itrix Compliance Regulatory Model2U1P1D2U1P1D2U1P1D1.

9 Published Ethernet interfaces compliant per 2. Performance varies depending on ciphers deployed. Contact your Citrix sales representative for details. 3. Hybrid SSL optimization (TLS1-ECDHE-RSA-AES182-SHA 256) Citrix | Citrix ADC Hardware Platforms5 Citrix ADC PlatformMPX/SDX 26200 MPX/SDX 26160 MPX/SDX 26100 AttributesMemory256 GB256 GB256 GBEthernet Ports18x 50GE QSFP28; 16x 25G SFP28 Transceivers Support50GE QSFP28 Port: 50GE/100GE QSFP28: SR4; 40GE QSFP+: SR4; 25GE SFP28: SR (Adapter required); 10GE SFP+: SR, LR (Adapter required); 25GE SFP28 Port: 25GE SFP28: SR; 10GE SFP+: SR, LRRAID SupportYesYesYesPay-as-you-grow & Burst Pack License Upgrades-Upgrade option to MPX/SDX 26200 Upgrade option to MPX/SDX 26200, 26160 PerformanceSystem Throughput (Gbps) [L4/L7 Throughput]200160100L4/L7 HTTP Requests/sec5,400,0004,300,0003,800,000 SSL Transactions/sec (2K Key Certificates)2310,000220,000140,000 ECDHE Transactions/sec130,00090,00060,000 SSL Throughput (Gbps)806451 Compression Throughput (Gbps)221713 ICA Proxy/SSL VPN Concurrent Users20,00020,00020,000 Included Instances, Maximum Instances (on SDX Platforms )

10 115, 11570, 11520, 115 Mechanical, Environmental, and RegulatoryPower Supplies222 Input Voltage, Frequency Range100-240 VAC full range, 50-60 Hz100-240 VAC full range, 50-60 Hz100-240 VAC full range, 50-60 HzOptional DC Power SupplyYesYesYesMax Power Supply1000W1000W1000 WTypical, Max Power Consumption583W, 718W583W, 718W583W, 718 WWeight (lbs)484848 Height2U2U2 UWidthEIA 310-D, IEC 60297, DIN 41494 SC48D rack width with mounting cm (28 i)