Example: quiz answers

cleVis hanGers - Anvil EPS

cleVis hanGers Tubing HangersPipeRingsClevis HangersSteel PipeClampsSocketClampsStructuralAttachme ntsBracketsCeiling Plates& FlangesConcrete Inserts& AttachmentsHangerRodsRod AttachmentsBeamClampsTable ofContentsCPVCPipe HangersGeneralNotesStainless SteelHangersBolts, Nuts,Pins & U-BoltsFIG. 260 ISS SIzING TABLEC opperTubeSizeInsulation Thickness1/2"3/4"1"11/2"2"(Size Number)3/8223 1/2223 5/8223 3/4223 1233 11/4333 11/2334 2444 21/24556 35556831/2556884668885888810681010101081 010121212 FIG. 260 ISS SIzING TABLEPipeSizeInsulation Thickness1/2"3/4"1"11/2"2"(Size Number)1/2223 3/4233 1233 11/2344 2445 21/25556835556831/2566884668885888101061 0101010108121212121210141414141612161616 16 Fig. 260 ISS cleVis hanger with Insulation Saddle SystemSize Range: 1/2" through 12" pipe and accommodates up to 2" of : Carbon steel with high impact glass reinforced polypropylene saddle andcarbon steel pipe : Plain or Galvanized cleVis HangerService: Recommended for the suspension of stationary insulated chilled or hotwater pipe Temperature: 40 F to 200 FApprovals: Dual Fire Ratings, UL E94 VO and ASTM E84 Class 1 25 : hanger load nut above cleVis must be tightened securely to assureproper performance.

cleVis hanGers 44 www.anvilintl.com Fig. 260 ISS Clevis Hanger with Insulation Saddle System (cont.) Application: Anvil's insulation saddle system clevises are fully tested ...

Tags:

  Hanger, Anvils, Clevis, Clevis hangers

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of cleVis hanGers - Anvil EPS

1 cleVis hanGers Tubing HangersPipeRingsClevis HangersSteel PipeClampsSocketClampsStructuralAttachme ntsBracketsCeiling Plates& FlangesConcrete Inserts& AttachmentsHangerRodsRod AttachmentsBeamClampsTable ofContentsCPVCPipe HangersGeneralNotesStainless SteelHangersBolts, Nuts,Pins & U-BoltsFIG. 260 ISS SIzING TABLEC opperTubeSizeInsulation Thickness1/2"3/4"1"11/2"2"(Size Number)3/8223 1/2223 5/8223 3/4223 1233 11/4333 11/2334 2444 21/24556 35556831/2556884668885888810681010101081 010121212 FIG. 260 ISS SIzING TABLEPipeSizeInsulation Thickness1/2"3/4"1"11/2"2"(Size Number)1/2223 3/4233 1233 11/2344 2445 21/25556835556831/2566884668885888101061 0101010108121212121210141414141612161616 16 Fig. 260 ISS cleVis hanger with Insulation Saddle SystemSize Range: 1/2" through 12" pipe and accommodates up to 2" of : Carbon steel with high impact glass reinforced polypropylene saddle andcarbon steel pipe : Plain or Galvanized cleVis HangerService: Recommended for the suspension of stationary insulated chilled or hotwater pipe Temperature: 40 F to 200 FApprovals: Dual Fire Ratings, UL E94 VO and ASTM E84 Class 1 25 : hanger load nut above cleVis must be tightened securely to assureproper performance.

2 Position the pipe on the saddle. Notch insulation to fit aroundthe saddle. Square cut adjoining insulation and butt the insulation ends to eachother. Insulation joint is coated, caulked and taped following standard insulationpractice used on flanges and : Vertical adjustment without removing the hanger may be made 7/8"through 23/8" varying with the size of the cleVis . Tighten all nuts after : V-Block design cradles pipethrough out the entire erection bolt spacer included as standardkeeps the cleVis lower strap from collapsing. Eliminates: Wood blocks and standard shields Costly calcium silicate inserts Re-leveling of piping at each individual hanger after insulation is : Specify size number, pipe size,insulation thickness, figure number nameand 260 ISS: LoADS (LBS) wEIGHTS (LBS) DIMENSIoNS (IN)260 ISS Size Number*MaxLoadWeightRod SizeAC**Rod Take Out * Max load exceeds dead weight load requirement of pipe at max span, except 14 and 16 where max load is based on industry standard spacing of 14.

3 Further information on typical pipe spans and piping weight per length can be found on pages 249 and 251, respectively.** Based on maximum insulation thickness, variations due to pipe size and insulation thickness may " through 16"Patent #7,281, hanGers 260 ISS cleVis hanger with Insulation Saddle System (cont.)Application: Anvil 's insulation saddle system clevises are fully tested and rated for a temperature range from 40 F to 200 F. Ideal for the sus-pension of stationary insulated chilled or hot water water Testing: Extensive field-testing and inspection has been performed to confirm that the integrity of the insulation vapor barrier for chilled water systems are sustained with the 260 Assure Proper Vapor Barrier: Each insulation joint should be properly coated, caulked and taped. Applying standard insulation practice that is used on flanges and : The Anvil 260 (ISS) Insulation Saddle System reduces your overall installation time and greatly simplifies the way you insulate copper and steel pipe systems.

4 Contractors can support insulated pipe with less parts and revolutionary design of the 260 ISS spreads the load evenly over the lower strap of the cleVis . The innovative V-Block design cradles the pipe at the design elevation throughout the erection process. The wide base V-Block design accommodates multiple pipe sizes, reducing the on-site inventory and the flexibility of pipe and insulation combinations with each size & UL Fire Ratings: The 260 ISS has been independently tested by ASTM and UL for: Flame Spread Index (FSI) Smoke Development (SD) and drip ratingsApprovals from both agencies with the highest ratings for the type of Thermal Conductivity: V-Block low thermal conductivity of .77 FInsulation R-Values: The Figure 260 ISS polymer V-Block component has an R-value ranging from to , depending on the hanger size. Meets or exceeds most commercial insulation hanGers Tubing HangersPipeRingsClevis HangersSteel PipeClampsSocketClampsStructuralAttachme ntsBracketsCeiling Plates& FlangesConcrete Inserts& AttachmentsHangerRodsRod AttachmentsBeamClampsTable ofContentsCPVCPipe HangersGeneralNotesStainless SteelHangersBolts, Nuts,Pins & U-BoltsFig.

5 260 ISS cleVis hanger with Insulation Saddle System (cont.)Easy InstallationMake sure the double hex nuts installed with the upper hanger load nut above the cleVis are tightened securely. Position pipe on 1 STEP 2 STEP 3 Square CutSTEP 4 Cope or notch insulation to fit around saddle. The notch should be deep enough to extend 1/8" to 1/4" beyond the the notched insulation section over cut adjoining insulation and butt the insulation ends to each joints and finish assure proper vapor barrier: Each insulation joint should be properly coated, caulked and taped. Applying standard insulation practice that is used on flanges and via standard taping chilled systems a mastic for thermal insulations or similar sealant is typically used:Systems (50 F or greater) apply sealant to: The coped and flat edges of the mating insulation sections. The V-Block saddle at the insulation (Below 50 F) apply sealant as per 50 Degrees with additional sealant to: The V-Block saddle joint between the two saddle sealant applied to V-Block saddle joint between the two saddle halves.

6 (Chilled water below 50 F)Mastic applied to V-Block saddle at insulation interface. (50 F or greater) hanGers 300 Adjustable cleVis for Insulated LinesSize Range: 3 4" through 12"Material: Carbon steelFinish: Plain, Galvanized or Epoxy coatedService: Recommended for suspension of insulated stationary pipe Temperature: Plain 650 F, Galvanized and Epoxy 450 FApprovals: Complies with Federal Specification A-A-1192A (Type 1) WW-H-171-E (Type 1), ANSI/MSS SP-69 and MSS SP-58 (Type 1).Installation: hanger load nut above cleVis must be tightened securely to assure proper hanger : Vertical adjustment is provided, varying with the size of the cleVis . Tighten upper nut after : Designed for 2" of insulation on 3 4" through 1 1 2" pipe and 4" of insulation on 2" and larger pipe. When properly installed, cleVis bolt is outside the : Specify pipe size, figure number, name and 300: LoADS (LBS) wEIGHT (LBS) DIMENSIoNS (IN)PipeSizeMaxLoadWeightRod Size ABCEA djustmentFGHIW idth Lower3 835 841 427 81 21 1631 45 811 1651 435 87 811 453 441 1611 16811 1661 215 8421 21, 287 16915 1671 223 8105 1679 1613 441, 893 8115 883 16115 1611 8125 883 413 41 261, 4105 81493 817 811/282, 8163 41125 813/4103, 8133 4193 16121 421 83 4123, 8219 16135 827 hanGers Tubing HangersPipeRingsClevis HangersSteel PipeClampsSocketClampsStructuralAttachme ntsBracketsCeiling Plates& FlangesConcrete Inserts& AttachmentsHangerRodsRod AttachmentsBeamClampsTable ofContentsCPVCPipe HangersGeneralNotesStainless SteelHangersBolts, Nuts,Pins & U-BoltsFig.

7 590 Adjustable cleVis for Ductile or Cast Iron PipeSize Range: 3" through 24" ductile or cast iron pipeMaterial: Carbon steelFinish: Plain or GalvanizedService: Recommended for the suspension of stationary ductile iron or cast iron : Complies with Federal Specification A-A-1192A (Type 1) WW-H-171-E (Type 1), ANSI/MSS SP-69 and MSS SP-58 (Type 1).Installation: hanger rod nut above cleVis must be tightened securely to assure proper hanger : Vertical adjustment without removing pipe may be made from 1 15 16" through 3 3 16", varying with the size of the cleVis . Tighten upper nut after : Specify pipe size, figure number, name and : Figure 590 sizes 12" and below typically feature a Figure 260 Top 590: LoADS (LBS) wEIGHT (LBS) DIMENSIoNS (IN) Pipe Pipe Size ABCEFG WidthLower31, 251 1671 1643 16 113 1611/441, 853 483 1643 4 115 1661, 471 8109 16515 1611/282, 8133 1671 221 413/4103, 8101 81511 1683 425 16123, 161811 161011 1627 82144, 4207 8115 1629 16164, 42215 16129 1627 1621/2184, 8265 8153 16313 16204, 4181 4291 16163 83244, 16331 4183 pipe clamps 261 Extension Pipe or Riser Clamp Size Range: 3 4" through 24"Material: Carbon steelFinish: Plain, Galvanized or Epoxy coatedService: For support of stationary steel pipe risers, cast iron pipeor conduit.

8 This product is not intended for use with hanger this application refer to Fig. 40 Riser Clamp, page Temperature: Plain 650 F, Galvanized and Epoxy 450 FApprovals: Complies with Federal Specification A-A-1192A (Type 8) WW-H-171-E (Type 8), ANSI/MSS SP-69 and MSS SP-58 (Type 8). UL, ULC Listed (Sizes 1 1 2" - 8").Installation: Clamp is fitted and bolted preferably below a coupling,hub or welded lugs on steel pipe. Bolt torques should be per industrystandards (see page 257). Clamp is designed for standard steel pipe this must be considered in sizing the riser for other types of : Specify pipe size, figure number, name and 261: LOAdS (LbS) WeIghT (LbS) dIMenSIOnS (In) TORQUe (FT-LbS)PipeSizeMaxLoadWeightLGWidthBCBo lt DiameterTorqueValues3 8127 83 83 811 211 437 41 27 163221 443 851 231 861 21 21 , 411 2861, 4982, 2125 85 42133 4122, 4153 4162, 2193 43 43 4243, 433017 8190 LBCGCL note: Refer to Technical Data Section for cast iron soil pipe PiPe clamPs Tubing HangersPipeRingsClevis HangersSteel PipeClampsSocketClampsStructuralAttachme ntsBracketsCeiling Plates& FlangesConcrete Inserts& AttachmentsHangerRodsRod AttachmentsBeamClampsTable ofContentsCPVCPipe HangersGeneralNotesStainless SteelHangersBolts, Nuts,Pins & U-BoltsFig.

9 40 Riser Clamp StandardSize Range: 2" through 24"Material: Carbon steel (CS), Alloy (A), or Stainless Steel (SS)Finish: Plain or GalvanizedMaximum Temperature: Galvanized 450 F, 650 F (CS), 950 F (A) and 1,000 F (SS)Service: Riser clamps are used for the support of vertical piping. Load is carried by shear lugs which are welded to the pipe. Shear lugs provided upon request. Local pipe wall stress evaluation available upon : Complies with Federal Specification A-A-1192A (Type 42),ANSI/MSS SP-69 and MSS SP-58 (Type 42).ordering: Specify pipe size, material, figure number, name and : If different loads or dimensions are required, refer to Fig. 40 SDspecial design riser 40: LoADS (LBS) wEIGHT (LBS) DIMENSIoNS (IN)Pipe SizeMax LoadC-CEF (max)G (max)SA (CS)A (alloy) (SS)B (max)Maximum Weight EachRigid AssemblySpring AssemblyCSSSA lloy29001,8001891 221/23 411 47 8218151821 2201020202031,5003,0005 83111 230253042,2004,40022113 411 411 840404454245404563,0006,00024127 811 27 811 4606073827131 25828282105,50011,000301511 4621 411 415 83157157157127,80015,600321611 2721 213 817 821620225014341713 8228228263169,00018,0003618811 223142773151839191 293383383772013,50027,000422121031 225 825 841 45255255802445221 211621565681 Fig.

10 140, 146 Field WeldedShear LugsFig. 290 Fig. 40 PIPESPACERS izes 16" to 20" have (4) inner DIA. FEEC to CBASG (max) PiPe clamPs 103 Offset Pipe ClampSize Range: 3 4" through 8"Material: Carbon steelFinish: Plain or GalvanizedService: For use in supporting piping away from wall or Temperature: Plain 650 F, Galvanized 450 Fordering: Specify pipe size, figure number, name and finishService: For use in supporting horizontal piping away from the wall or floor (not to be used as a riser type support)FIG. 103: LoADS (LBS) wEIGHT (LBS) DIMENSIoNS (IN)PipeSizeMaxLoadWeightWBDBolt Dia. FGWidth3 421 27 163 811 425 811 4213 1611 433 169 161 221 437 833 841 411 843 411 165 455 465 16 BBolt Dia. FWLOADHOLE SIZEDCLGFig. 100 Extended Pipe ClampSize Range: 1 2" through 8"Material: Carbon steelFinish: Plain or GalvanizedService: For attachment to structure without use of Temperature: Plain 650 F, Galvanized 450 Fordering: Specify pipe size, figure number, name and 100: wEIGHT (LBS) DIMENSIoNS (IN)PipeSizeWEFGW idthHWeight1 255 827 83 8141 457 831 811 441 835 467 841 851 271 843 853 851 81 267 287 855 873 481 873 811 291 885 85 82107 293 2113 8"EFG12" PiPe clamPs Tubing HangersPipeRingsClevis HangersSteel PipeClampsSocketClampsStructuralAttachme ntsBracketsCeiling Plates& FlangesConcrete Inserts& AttachmentsHangerRodsRod AttachmentsBeamClampsTable ofContentsCPVCPipe HangersGeneralNotesStainless SteelHangersBolts, Nuts,Pins & U-BoltsFig.