Example: quiz answers

Clinical Chemistry and Immunoassay Testing …

Hitachi Review Vol. 57 (Jan. 2008) 1. Clinical Chemistry and Immunoassay Testing supporting the Individual Healthy Life Kyoko Imai OVERVIEW: Clinical laboratory Testing provides the information needed Shigenori Watari for the diagnosis and treatment of disease. Hitachi's automated analyzers for Clinical Testing have undergone rapid advancement since the shipping Taku Sakazume of the first system manufactured (Japan) in 1971. Efforts to increase the Satoshi Mitsuyama reliability of Clinical data and measurement sensitivity have rapidly increased the test menu that can be measured in Clinical Chemistry Testing and Immunoassay . Furthermore, the integration of automated Chemistry analyzers and Immunoassay systems has made it possible to do both Chemistry Testing and Immunoassay with a single system, thus reducing the workload in Clinical laboratories. Now, as policies for control of medical expenses are becoming increasingly strict, there is a demand for even more efficiency in the automated analyzer and for higher quality in the test data.

Clinical Chemistry and Immunoassay Testing Supporting the Individual Healthy Life 2 Albumin Ammonia Bicarbonate Bilirubin-direct Bilirubin-total

Tags:

  Testing, Chemistry, Clinical, Supporting, Clinical chemistry and immunoassay testing, Immunoassay, Clinical chemistry and immunoassay testing supporting

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Clinical Chemistry and Immunoassay Testing …

1 Hitachi Review Vol. 57 (Jan. 2008) 1. Clinical Chemistry and Immunoassay Testing supporting the Individual Healthy Life Kyoko Imai OVERVIEW: Clinical laboratory Testing provides the information needed Shigenori Watari for the diagnosis and treatment of disease. Hitachi's automated analyzers for Clinical Testing have undergone rapid advancement since the shipping Taku Sakazume of the first system manufactured (Japan) in 1971. Efforts to increase the Satoshi Mitsuyama reliability of Clinical data and measurement sensitivity have rapidly increased the test menu that can be measured in Clinical Chemistry Testing and Immunoassay . Furthermore, the integration of automated Chemistry analyzers and Immunoassay systems has made it possible to do both Chemistry Testing and Immunoassay with a single system, thus reducing the workload in Clinical laboratories. Now, as policies for control of medical expenses are becoming increasingly strict, there is a demand for even more efficiency in the automated analyzer and for higher quality in the test data.

2 To meet that demand, Hitachi continues to improve the functionality of the automated analyzer. INTRODUCTION. Testing for the constituents of blood and urine provides evidence for diagnosis, and has been effective in the early detection and prediction of illness. Hitachi extended spectrometer technology to Clinical Testing , and in 1971 it shipped the 400 model, Japan's first domestically produced automated Chemistry analyzer. The automated Chemistry analyzer rapidly measures enzymes, lipids, electrolytes, proteins and other such components in blood and urine, a process known as Fig. 1 Next-generation cobas 6000 Analyzer Series Automated biochemical Testing . The system is widely used by Analyzer. many hospitals and clinics for diagnosis and The cobas c 501 analyzer for Clinical Chemistry Testing (left). and the cobas e 601 analyzer for Immunoassay (right) are comprehensive health examinations. combined. The system is marketed worldwide by Roche In the 1980s, there was a high demand for Diagnostics.

3 Measurement of hormones and cancer markers and other such disease-specific labels. Many of such that integrates biochemical Testing and Immunoassay components exist in the blood serum only in very small to reduce the Clinical Testing workload. In response to amounts. For that reason, Immunoassay techniques that demand, Hitachi led the world in developing an were developed. Immunoassay uses the highly specific integrated automated analyzer product. antigen-antibody reaction, and thus features highly The current environment of strict policies sensitive measurement. Immunoassay was initially concerning the cost of medical care demands positioned as special Testing . A special automated improvements in the automated analyzer for even analyzer was developed for immunology and its use higher efficiency and test data quality. Hitachi rapidly spread. With the increasing use of continues to improve automated analyzer functionality Immunoassay , a high demand developed for a system to meet that demand.

4 Clinical Chemistry and Immunoassay Testing supporting the Individual Healthy Life 2. NEXT-GENERATION AUTOMATED system covers about 95% of the workload for ANALYZER WITH EXPANDED TEST MENU biochemistry and Immunoassay Testing . Hitachi, in collaboration with Roche Diagnostics, The progression in the number of test menus that has developed the biochemical and Immunoassay can be analyzed for the Hitachi model 400 automated automated analyzer for Clinical Testing , and that system analyzer and the Hitachi model 705 automated holds the top share of the world market. The most analyzer(3), a world-wide best seller that was first recent next-generation automated analyzer, the cobas* shipped in 1980, is shown in Table 1. With the most 6000 analyzer series(1), is shown in Fig. 1. recent generation cobas 6000 analyzer series, there was The cobas 6000 analyzer series combined the cobas a very large increase in analysis test menus. c 501 analyzer for biochemical Testing and the cobas e 601 analyzer for Immunoassay into a single integrated INCREASING Clinical DATA RELIABILITY.

5 System. It was equipped with new technology and new We take the cobas 6000 analyzer series as an functions, and the number of test menus that it could example of our efforts to increase the reliability of test rapidly increased. Now, in October 2007, the Clinical data. system can measure over 150 test menus in biochemical and Immunoassay Testing .(2) This single Reduction of Sample Carry-over The concentration range of blood constituents may *cobas is a registered trademark of Roche Diagnostics. extend to the 6th decimal place, so measures to reduce TABLE 1. Changes in Test Menus Each generation of automated analyzer adds new test menus. The latest cobas 6000 analyzer series can measure over 150 biochemical and Immunoassay test menus with a single system. Model Model cobas Model Model cobas Model Model cobas Model Model cobas 400 705 6000 400 705 6000 400 705 6000 400 705 6000. Substrates Drugs of Abuse Proteins TDM, medication monitoring Albumin Amphetamines 1-Acid Glycoprotein Acetaminophen Ammonia Barbiturates 1-Antitrypsin Amikacin Bicarbonate Benzodiazepines 1-Microglobuline Carbamazepine Bilirubin-direct Cannabinoids 2-Microglobuline Cyclosporine Bilirubin-total Cocain Metabolite Albumin (immuno) Digitoxin Calcium Ethanol APO A1 Digoxin Cholesterol Methadone APO B Gentamicin HDL-Cholesterol Methaqualone ASLO Lidocaine LDL-Cholesterol Opiates ATIII Lithium Creatinine enz.

6 Phencyclidine C3c MPA. Creatinine Jaffe Propoxyphene C4 NAPA. Fructosamine LSD Ceruloplasmin Phenobarbital Glucose CRP Phenytoin Iron CRP High Sensitivity Procainamide Lactate Enzymes D-Dimer Quinidine Magnesium ACP Ferritin Salicylate Phosphorus ALP Haptoglobin Theophylline Total Protein ALT/GPT HbA1c (whole blood) Tobramycin Total Protein U/CSF Amylase-tot. IgA Valproic Acid Triglycerides Amylase-pancr. IgG Vancomycin Triglycerides GB AST/GOT IgM. UIBC Cholinesterase Kappa Light Chains Urea/Bun BUN CK Lambda Light Chains Uric Acid CK-MB Lipoprotein (a). GGT Myoglobin Electrolytes GLDH Prealbumin Chloride ISE ISE. HBDH RF Potassium ISE ISE. LDH Soluble Transferrin Receptor Sodium ISE ISE. Lipase Transferrin Animia Diabetes Cardiac Infectious Disease Ferritin C-Peptide CK-MB (mass) Anti-HAV. Folate Glucose CK-MB (mass) STAT Anti-HAV IgM. Iron HbA1c (whole blood) CRP High Sensitivity Anti-HBc Transferrin Insulin Myoglobin Anti-HBc IgM.

7 Vitamin B12 Myoglobin STAT Anti-HBe NT proBNP Anti-HBs Bone Metabolism Tumor Markers Troponin T CMV IgG. -CrossLaps AFP Troponin T STAT CMV IgM. Calcium CA 125 HBeAg Osteocalcin CA 15-3 HBsAg 25- (OH) 2 Vitamin D3 CA 19-9 Featility/Hormones HIV Ag P1NP CA 72-4 ACTH HIV combi PTH CEA Cortisol Rubella IgG. CYFRA 21-1 DHEA-S Rubella IgM. Thyroid Function Free PSA Estradiol Toxo IgG. Anti-Tg NSE FSH Toxo IgM. Anti-TPO S-100 HCG+ . FT3 Total PSA HCG STAT. FT4 LH. T3 PAPP-A Others T4 Rheumatoid Arthritis Progesterone IgE. T-uptake Anti-CCP Prolactin Serum Index TG SHBG RBC Folate Hemolyzing Reagent TSH Testosterone Total Mycophenolic Acid TSHr Ab : Clinical Chemistry ISE: biochemical ion- : Immunoassay Testing , cobas 6000 e 601 analyzer selective electrode * : currently under development Hitachi Review Vol. 57 (Jan. 2008) 3. Pressure sensor Generation of rotational flow Sample probe 0 Normal Pressure (kPa). Reaction solution Mixer 40.

8 Clogged Reaction vessel Drawing Reaction interval 80. vessel 0 1 Sample Syringe Time (s). Piezoelectric device container Fig. 2 Ultrasonic Mixer.(4) Fig. 4 Pressure Monitoring as Sample is Drawn.(9). The reaction solution is mixed by a vertical rotational flow The pressure waveform within the sample probe is compared to induced within the reaction vessel. a normal waveform to detect clogging in the sample probe. items that are evaluated as positive or negative, such as infectious items. The parts of the cobas e 601 analyzer that come in contact with the sample are disposable. Disposable sample pipette tips and reaction vessel are used and the mixing method involves no contact, so sample Fig. 3 Non-contact Mixing of the Reaction Solution. carry-over is eliminated. High-speed photographs of a pigmented aqueous solution being mixed in special reaction incubator and reaction vessel. Reduction of Problems Caused by Sample Intake Patient samples may contain fibrin or other solid carry-over between samples are required when samples materials that can clog the sample probe and prevent from many patients are processed consecutively the drawing in of the prescribed amount of sample.

9 To through the same sample pipette mechanism or the detect the drawing in of foreign material or other such same reagent mixing mechanism in an automated abnormalities, a pressure sensor is placed in the flow analyzer. path between the sample probe and the syringe to To reduce sample carry-over, the cobas c 501 monitor the flow pressure (see Fig. 4). The change in analyzer implements a non-contact type of reagent pressure within the sample probe is analyzed to mixing(4). A piezoelectric device is used to subject the automatically detect abnormalities such as clogging side of the reaction vessel to high-frequency ultrasonic of the sample probe(9). Confirming that the specified sound waves, which create a rotating flow within the amount of sample is drawn ensures the reliability of reaction vessel to mix the reagents (see Fig. 2). test results. In earlier systems, the mixing of sample and reagent was done by inserting a stirring rod into the liquid.

10 Reduction of Problems Caused by Reagents The non-contact method eliminates sample carry-over To reduce the problems caused by the handling of by liquid adhering to the stirring rod(5), (6), (7). Stirring reagents, and thus ensure the reliability of analysis by ultrasonic waves(8) is illustrated in Fig. 3. data, we use premeasured reagent packs(1) (see Fig. Immunoassay requires even more rigorous 5). The prepared reagent packs eliminate human error reduction of sample carry-over than does biochemical in the preparation of reagents, and so reduce problems. Testing . For example, in the case of test items that have Also, because the packs can be simply set into the a wide range of concentrations in blood, such as the system, the work of preparing the reagents and HCG (human chorionic gonadotropin stimulating inserting them into the system can be eliminated. The hormone) used in pregnancy Testing , a large carry-over reagent pack is fitted with a cover called the lid so that from a highly concentrated sample to the next patient it is always sealed.


Related search queries