Example: tourism industry

Clips & fastener for ASHRAE Filters

FastenersCamfil Farr fastener are available for built-upbank holding frames or housings that incorporateframes to ensure that air Filters fit securely in theholding gap around a 24 by 24 filter may result in as much as 18% air bypass, orthe equivalent of a 3 hole in the middle of thefilter. The use of the correct fastener , and theproper number of fastener , ensures that the airmoving through the system will be wholly treatedby the air Filters ensuring improved indoor airquality for the Farr fastener are:- available in many different variations-configurations available for Camfil Farr holding frames or holding frames by other manufacturers-standard construction of high tensile strengthsteel or cad-plated in many configurations - available in stainless steel-may be combined to apply up to four stagesof filtration.

fasteners Camfil Farr fastener are available for built-up bank holding frames or housings that incorporate frames to ensure that air filters fit securely in the

Tags:

  Fastener, Holdings, Clip, Filter, Ashrae, Clips amp fastener for ashrae filters

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Clips & fastener for ASHRAE Filters

1 FastenersCamfil Farr fastener are available for built-upbank holding frames or housings that incorporateframes to ensure that air Filters fit securely in theholding gap around a 24 by 24 filter may result in as much as 18% air bypass, orthe equivalent of a 3 hole in the middle of thefilter. The use of the correct fastener , and theproper number of fastener , ensures that the airmoving through the system will be wholly treatedby the air Filters ensuring improved indoor airquality for the Farr fastener are:- available in many different variations-configurations available for Camfil Farr holding frames or holding frames by other manufacturers-standard construction of high tensile strengthsteel or cad-plated in many configurations - available in stainless steel-may be combined to apply up to four stagesof filtration.

2 Clips & fastener for ASHRAE FiltersCamfil FarrProduct sheetCamfil Farr Fasteners2902 - 0705 Camfil Farr - clean air solutionsCamfil Farr fastenerensure that your systemefficiency will be equivalentto your filter : Camfil Farr frames are prepunched to accept a variety offastener. fastener are also available for other manufacturersframes. Three of the most common are shown here, C-80, C-71 and : Using a combination of fastener , users may apply upto four stages of filtration in one built-up filter bank. In thisphoto, a 4 deep 30/30 is secured to a 12 : C-702: C78-13: C-794: C-78-65: C-836: C-807: C-718: C-779: C-86 (C-89)Some of the fastener 1A: 2 pleated filter with 1B: C-70 fastener positioning,lower for 1 deep filter , upper for 2 deep 1C: C-86 fastener for 4 deepfilter in Type 8 1D: C-86 fastener 2A:C-70 positioning for Hi-Flo or other pocket style filtersPhoto 2B: C-70 positioning for HP fame assemblyPhoto 2C: C-70 positioning for header-type box filtersPhoto 3A:C-80 positioning in Type 3B: C-80 positioning on 3C: C-80 positioning 3D: Riga-Flo and Aeropacfilters have pilot holes for 4A:Externally supported retainer for front access tab ate each corner of the holding frame locks retainer inposition (optional).

3 Photo 4B: C-71-12 fastener 4C: C-71-12 fastener with retainer in position. Small loopis positioned over between outside double bar of 5A:C-79-1 and C-79-2 fastener positioning for 2 deepand 4 deep pleated Filters (respectively).Photo 5B: C-79-2 fastener with Riga-Flo and 4 deep 30 shown on this page are not drawn to scale. Items are shown for relative fastener DATAFASTENERSA pplications(four fastener required per filter , see sales drawing 050202)AccessModelNumberPartNumber30/30 Aeropleat orUltrasolve in Type 8holding frame1 or 2 deep filterU or DC-70050025-0004 deep filter (use C-77 for Ultrasolve)UC-86074437-000U or DC-77 1059615-0012 deep filter as a prefilter to a Riga-Flo, or Aeropac (no header)U or DC-79-1061179-0014 deep filter as a prefilter to a Riga-Flo, or Aeropac (no header)UC-79-2061179-0024 deep Ultrasolve with 2 deep prefilterC-79-5061179-0054 deep Ultrasolve with 4 deep prefilterC-79-6061179-0062 deep filter as a prefilter to a Riga-Flo E-Series (no header)C-102-1124298-0014 deep filter as a prefilter to a Riga-Flo E-Series (no header)

4 C-102-2124298-0021 deep filter as a prefilter in the same frame with Hi-Flo, Riga-FloPH-A or Aeropac (single header)C-70 4050025-0002 deep filter as prefilter in the same frame with Hi-Flo, Riga-Flo PH-A or Aeropac (single header)(Two C-70 should be used to hold headered filter in place, and twoC-86 fastener ( or C-77) should be used to hold prefilter in would be on opposite corners)C-86 orC-77 1& C-70074437-000 or 059615-001 &050025-0004 deep filter as a prefilter in the same frame with Hi-Flo, Riga-FloPH-A or Aeropac (single header)C-89 4 &C-70078865-0002 deep filter as a prefilter in the same frame with Aeropac (doubleheader)C-103-1403229-0014 deep filter as a prefilter in the same frame with Aeropac (doubleheader)C-103-2403229-00230/30 Aeropleat orUltrasolve in holding framesby other manufacturers1 deep filterU or DC-78-1059920-0012 deep filterC-78-2059920-0024 deep filterC-78-4059920-0031 deep filter as a prefilter to a Hi-Flo or Riga-Flo PH-AUC-78-2 4059920-0022 deep filter as a prefilter to a Hi-Flo or Riga-Flo PH-AC-78-3 4059920-0044 deep filter as a prefilter to a Hi-Flo or Riga-Flo PH-AC-78-5 4059920-0062 deep filter as a prefilter to a UltrasolveC-78-7059920-008 NOTES:1 When using the Farr 30/30 Class 1 filter in this application, a C-77 fastener should be fastener can be used for upstream application, however it is not is also available in place of the C-80 to allow for more clearance downstream.

5 4Hi-Flo Filters can be accessed from either upstream or secure a Riga-Flo PH or Durafil using upstream access only, use a C-70 fastener , part number 050025-000. For the Durafil only, the C-70 fastener may be used on thedownstream as well. 6 The terms upstream (U) and front access are synonymous, as are downstream (D) and rear upstream access & downstream access (Durafil and Aeropac only) where the filter goes through frame opening a C-70 fastener should be used. When the filter doesnot go through the frame opening then a C-80 or a C-100 (Aeropac only).Continued on next Farr, States Tel: (973) 616-7300 Fax: (973) 616-7771 Canada Tel: (450) 629-3030 Fax: (450) 662-6035E-mail: Camfil Farr has a policy of uninterrupted research,development and product improvement. We reserve the rightto change designs and specifications without notice.

6 Applications(four fastener required per filter , see sales drawing 050202)AccessModelNumberPartNumberRiga-F lo in Type 8holding frameTo secure 12 deep filter 24 x 24 U or DC-80 5orC-99061180-000or114353-000To secure 12 deep filter 24 x 12 To secure 6 deep filter 24 x 24 C-90 2orC-99 2078948-000or078948-000To secure 6 deep filter 24 x 12 To secure 6 deep filter as a prefilter to a 12 deep filter 24 x 24 C-91079445-000To secure 6 deep filter as a prefilter to a 12 deep filter 24 x 12 C-912E-SeriesRiga-Flo in Type 8holding frameTo secure 12 deep filter 24 x 24 U or DC-80 or C-99061180-000 or114353-000To secure 12 deep filter 24 x 12 C-80 2orC-99 2061180-000 or114353-000 Riga-Flo in holding frames by other manufacturersTo secure 12 deep filter 24 x 24 U or DC-83062529-000To secure 12 deep filter 24 x 12 C-83 2To secure 6 deep

7 filter 24 x 24 C-83-6079618-000To secure 6 deep filter 24 x 12 C-83-6 2 Aeropac Durafil Riga-Flo PHHi-Flo in Type 8holding frameTo secure 12 deep Aeropac (no header) 24 x 24 , 24 x 12 U or DC-80 3orC-99 2061180-000 or114353-000To secure a single header pocket style filter (Hi-Flo)U or DC-70050025-000To secure a 12 deep single header style filter (Riga-Flo PH, Durafil,Aeropac)U or DC-70050025-000To secure a 12 deep single header Aeropac style filter DC-100114646-000To secure a 12 deep double header style filter UC-80 orC-100061180-000To secure 6 deep single header style filter UC-70050025-000U or DC-90078948-000 NOTES:1 When using the Farr 30/30 Class 1 filter in this application, a C-77 fastener should be fastener can be used for upstream application, however it is not is also available in place of the C-80 to allow for more clearance downstream.

8 4Hi-Flo Filters can be accessed from either upstream or secure a Riga-Flo PH or Durafil using upstream access only, use a C-70 fastener , part number 050025-000. For the Durafil only, the C-70 fastener may be used on thedownstream as well. 6 The terms upstream (U) and front access are synonymous, as are downstream (D) and rear upstream access & downstream access (Durafil and Aeropac only) where the filter goes through frame opening a C-70 fastener should be used. When the filter doesnot go through the frame opening then a C-80 or a C-100 (Aeropac only).APPLICATION DATAFASTENERS (continued)


Related search queries