CLOGGING INDICATORS Visual and electrical …

ACCESSORIESCLOGGING INDICATORSV isual and electrical indicatorsThe Pressure indicator measures the pressure in one point only:-for suction application it must be located downstream the filter element (P-)-for return application it must be located upstream the filter element (P+)The Differential indicatormeasures the Dp between upstream and down-stream of the filter element, it is the ideal indicator for in line Pressure Drop(Dp = differential pressure)through the filter increases during the systemoperation due to the contaminant retained by thefilter filter element must be replaced when the indica-tor shows an alarm and before the Dp reaches theby-pass set value ( the set value A of the cloggingindicator must always be lower that the set value B ofthe by-pass valve).

INDICATORS FOR APPLICATION ON RETURN LINE NORMALLY USED ON FA-1 (e lie) / FA-2 / FR-1 / FR-8 / FCR-7 The clogging indicator registers the pressure downstream the filter element:

Tags:

  Indicator, Clogging, Clogging indicators

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of CLOGGING INDICATORS Visual and electrical …

1 ACCESSORIESCLOGGING INDICATORSV isual and electrical indicatorsThe Pressure indicator measures the pressure in one point only:-for suction application it must be located downstream the filter element (P-)-for return application it must be located upstream the filter element (P+)The Differential indicatormeasures the Dp between upstream and down-stream of the filter element, it is the ideal indicator for in line Pressure Drop(Dp = differential pressure)through the filter increases during the systemoperation due to the contaminant retained by thefilter filter element must be replaced when the indica-tor shows an alarm and before the Dp reaches theby-pass set value ( the set value A of the cloggingindicator must always be lower that the set value B ofthe by-pass valve).

2 WARNING:in cold start conditions a false alarm can be caused by higher oilviscosity due to low temperature; the indicator alarm must be considered atnormal working temperature pRETAINED CONTAMINANT (g)(ELEMENT LIFE (h))P+ABP- INDICATORS FOR APPLICATION ON SUCTION LINENORMALLY USED ON FS-7 / FA-1 series (suction line) The CLOGGING indicator registers the pressure downstream the filter element: in the Visual indicator the red area shows the need for element replacement. in the ELECTRIC indicator an electrical switch is VACUUM GAUGE0 -1 barS13 2 SWITCH-0,2 bar DC: 30 V 4 A inductive, 3 A resistive AC: 250 V 3 A inductive, 2 A resistive Protection: IP65, connector DIN43650 SPDT contactsClogging indicators225 Nm25 NmCODEDIMENSIONSSYMBOLDESCRIPTIONLC24 oGR+-4~~The LC24 connector can replace thestandard black connector of the S13 indicator .

3 ( supplied separately)Feeded with 24V, it gives a Visual indicationof the filter element conditions: normally theGREEN LED is on, the RED LED switch onwhen the element is FOR APPLICATION ON RETURN LINENORMALLY USED ON FA-1 (return line) / FA-2 / FR-1 / FR-8 / FCR-7 The CLOGGING indicator registers the pressure downstream the filter element: in the Visual indicator the red area shows the need for element replacement. in the ELECTRIC indicator an electrical switch is indicators3 CODEDIMENSIONSSYMBOLSETTINGR9 PRESSURE GAUGE0 1 bar 1 1,5 bar1,5 4 bar R10 R13 2 SWITCHR13=1,3 barR14 = 2 bar DC: 30 V 4 A inductive, 3 A resistive AC: 250 V 3 A inductive, 2 A resistive Protection: IP65, connector DIN43650 SPDT contactsR1425 Nm25 Nm25 NmCODEDIMENSIONSSYMBOLDESCRIPTIONLC24 oGR+-4~~The LC24 connector can replace thestandard black connector of the R13 and R14 indicator .

4 ( supplied separately)Feeded with 24V, it gives a Visual indicationof the filter element conditions: normally theGREEN LED is on, the RED LED switch onwhen the element is MULTIPURPOSE FOR APPLICATION ON SUCTION AND RETURN LINECAN BE USED ON FS-7 / FA-1(suction line)ORFA-1(return line) / FA-2 / FR-1/ FR-8 / FCR-7 CODEDIMENSIONSSYMBOLSETTINGR7 PRESSURE / VACUUM GAUGE-1 -0 ,2 b ar - 0,2 1,4 b ar1,4 5 barClogging indicators4 INDICATORS FOR APPLICATION ON LOW PRESSURE LINENORMALLY USED ON FA-1 (low pressure line) seriesCODEDIMENSIONSSYMBOLSETTINGR12 PRESSURE GAUGE0 16 bar25 Nm25 NmDIFFERENTIAL CLOGGING INDICATORSV05 / E05 NORMALLY USED ON F040-DMD / F100-XD / F160-XD / F280-D1 / F420-D1 seriesV08 / E08 NORMALLY USED ON F100-XD / F160-XD / F280-D1 / F420-D1 seriesV02 / E02 NORMALLY USED ON F040-DMD series CLOGGING indicators5 CODEDIMENSIONSSYMBOLSETTINGV02 DIFFERENTIAL VISUAL2,7 barV05 DIFFERENTIAL VISUAL5 barV08 DIFFERENTIAL VISUAL8 bar50 NmCODEDIMENSIONSSYMBOLSETTINGE02 oDIFFERENTIAL ELECTRIC2.

5 7 barE05 DIFFERENTIAL ELECTRIC5 barE08 DIFFERENTIAL ELECTRIC8 bar50 Nm Electric plug connection as per DIN 43650 Protection: IP65 acc. to DIN 40050 Max current: 5A resistive 1A inductive Max voltage: 250V AC - 30V DCCODEDIMENSIONSSYMBOLDESCRIPTIONLC24 oGR+-4~~The LC24 connector can replace thestandard black connector of the E indicator . ( supplied separately)Feeded with 24V, it gives a Visual indicationof the filter element conditions: normally theGREEN LED is on, the RED LED switch onwhen the element is CLOGGING INDICATORS CLOGGING indicators6EX5 / VX5 NORMALLY USED ON FD-3 / FDM-D1 seriesEX8 / VX8 NORMALLY USED ON FDM-D1 series Electric plug connection as per DIN 43650 Protection: IP65 acc.

6 To DIN 40050 Max current: 5A resistive 1A inductive Max voltage: 250V AC - 30V DCCODEDIMENSIONSSYMBOLSETTINGVX5 DIFFERENTIAL VISUAL5 barVX8 DIFFERENTIAL VISUAL8 bar50 NmCODEDIMENSIONSSYMBOLSETTINGEX5 oDIFFERENTIAL ELECTRIC5 barEX8 DIFFERENTIAL ELECTRIC8 bar50 NmCODEDIMENSIONSSYMBOLDESCRIPTIONLC24 oGR+-4~~The LC24 connector can replace thestandard black connector of the E indicator . ( supplied separately)Feeded with 24V, it gives a Visual indicationof the filter element conditions: normally theGREEN LED is on, the RED LED switch onwhen the element is CLOGGING INDICATORS Z34 / Z35 NORMALLY USED ONFA-4 series CODEDIMENSIONSSYMBOLSETTINGZ34 DIFFERENTIAL VISUAL2,7 barZ35 1 DIFFERENTIAL ELECTRIC 2,7 bar Max current: 0,5A resistive0,2A inductive Max voltage: 36 VDC Protection: IP54 as per DIN 40050 CLOGGING indicators750 Nm50 NmTechnical information may change without noticeClogging indicatorsw w w.