Transcription of CLOGGING INDICATORS Visual and electrical ... - …
1 ACCESSORIESCLOGGING INDICATORSV isual and electrical indicatorsThe Pressure indicator measures the pressure in one point only:-for suction application it must be located downstream the filter element (P-)-for return application it must be located upstream the filter element (P+)The Differential indicatormeasures the Dp between upstream and down-stream of the filter element, it is the ideal indicator for in line Pressure Drop(Dp = differential pressure)through the filter increases during the systemoperation due to the contaminant retained by thefilter filter element must be replaced when the indica-tor shows an alarm and before the Dp reaches theby-pass set value ( the set value A of the cloggingindicator must always be lower that the set value B ofthe by-pass valve).
2 WARNING:in cold start conditions a false alarm can be caused by higher oilviscosity due to low temperature; the indicator alarm must be considered atnormal working temperature pRETAINED CONTAMINANT (g)(ELEMENT LIFE (h))P+ABP- INDICATORS FOR APPLICATION ON SUCTION LINENORMALLY USED ON FS-7 / FA-1 series (suction line) The CLOGGING indicator registers the pressure downstream the filter element: in the Visual indicator the red area shows the need for element replacement. in the ELECTRIC indicator an electrical switch is VACUUM GAUGE0 -1 barS13 2 SWITCH-0,2 bar DC: 30 V 4 A inductive, 3 A resistive AC: 250 V 3 A inductive, 2 A resistive Protection: IP65, connector DIN43650 SPDT contactsClogging indicators225 Nm25 NmCODEDIMENSIONSSYMBOLDESCRIPTIONLC24 oGR+-4~~The LC24 connector can replace thestandard black connector of the S13 indicator .
3 ( supplied separately)Feeded with 24V, it gives a Visual indicationof the filter element conditions: normally theGREEN LED is on, the RED LED switch onwhen the element is FOR APPLICATION ON RETURN LINENORMALLY USED ON FA-1 (return line) / FA-2 / FR-1 / FR-8 / FCR-7 The CLOGGING indicator registers the pressure downstream the filter element: in the Visual indicator the red area shows the need for element replacement. in the ELECTRIC indicator an electrical switch is indicators3 CODEDIMENSIONSSYMBOLSETTINGR9 PRESSURE GAUGE0 1 bar 1 1,5 bar1,5 4 bar R10 R13 2 SWITCHR13=1,3 barR14 = 2 bar DC: 30 V 4 A inductive, 3 A resistive AC: 250 V 3 A inductive, 2 A resistive Protection: IP65, connector DIN43650 SPDT contactsR1425 Nm25 Nm25 NmCODEDIMENSIONSSYMBOLDESCRIPTIONLC24 oGR+-4~~The LC24 connector can replace thestandard black connector of the R13 and R14 indicator .
4 ( supplied separately)Feeded with 24V, it gives a Visual indicationof the filter element conditions: normally theGREEN LED is on, the RED LED switch onwhen the element is MULTIPURPOSE FOR APPLICATION ON SUCTION AND RETURN LINECAN BE USED ON FS-7 / FA-1(suction line)ORFA-1(return line) / FA-2 / FR-1/ FR-8 / FCR-7 CODEDIMENSIONSSYMBOLSETTINGR7 PRESSURE / VACUUM GAUGE-1 -0 ,2 b ar - 0,2 1,4 b ar1,4 5 barClogging indicators4 INDICATORS FOR APPLICATION ON LOW PRESSURE LINENORMALLY USED ON FA-1 (low pressure line) seriesCODEDIMENSIONSSYMBOLSETTINGR12 PRESSURE GAUGE0 16 bar25 Nm25 NmDIFFERENTIAL CLOGGING INDICATORSV05 / E05 NORMALLY USED ON F040-DMD / F100-XD / F160-XD / F280-D1 / F420-D1 seriesV08 / E08 NORMALLY USED ON F100-XD / F160-XD / F280-D1 / F420-D1 seriesV02 / E02 NORMALLY USED ON F040-DMD series CLOGGING indicators5 CODEDIMENSIONSSYMBOLSETTINGV02 DIFFERENTIAL VISUAL2,7 barV05 DIFFERENTIAL VISUAL5 barV08 DIFFERENTIAL VISUAL8 bar50 NmCODEDIMENSIONSSYMBOLSETTINGE02 oDIFFERENTIAL ELECTRIC2,7 barE05 DIFFERENTIAL ELECTRIC5 barE08 DIFFERENTIAL ELECTRIC8 bar50 Nm Electric plug connection as per DIN 43650 Protection: IP65 acc.
5 To DIN 40050 Max current: 5A resistive 1A inductive Max voltage: 250V AC - 30V DCCODEDIMENSIONSSYMBOLDESCRIPTIONLC24 oGR+-4~~The LC24 connector can replace thestandard black connector of the E indicator . ( supplied separately)Feeded with 24V, it gives a Visual indicationof the filter element conditions: normally theGREEN LED is on, the RED LED switch onwhen the element is CLOGGING INDICATORS CLOGGING indicators6EX5 / VX5 NORMALLY USED ON FD-3 / FDM-D1 seriesEX8 / VX8 NORMALLY USED ON FDM-D1 series Electric plug connection as per DIN 43650 Protection: IP65 acc. to DIN 40050 Max current: 5A resistive 1A inductive Max voltage: 250V AC - 30V DCCODEDIMENSIONSSYMBOLSETTINGVX5 DIFFERENTIAL VISUAL5 barVX8 DIFFERENTIAL VISUAL8 bar50 NmCODEDIMENSIONSSYMBOLSETTINGEX5 oDIFFERENTIAL ELECTRIC5 barEX8 DIFFERENTIAL ELECTRIC8 bar50 NmCODEDIMENSIONSSYMBOLDESCRIPTIONLC24 oGR+-4~~The LC24 connector can replace thestandard black connector of the E indicator .
6 ( supplied separately)Feeded with 24V, it gives a Visual indicationof the filter element conditions: normally theGREEN LED is on, the RED LED switch onwhen the element is CLOGGING INDICATORS Z34 / Z35 NORMALLY USED ONFA-4 series CODEDIMENSIONSSYMBOLSETTINGZ34 DIFFERENTIAL VISUAL2,7 barZ35 1 DIFFERENTIAL ELECTRIC 2,7 bar Max current: 0,5A resistive0,2A inductive Max voltage: 36 VDC Protection: IP54 as per DIN 40050 CLOGGING indicators750 Nm50 NmTechnical information may change without noticeClogging indicatorsw w w . f i l t r e c . c o m