STRONGER THAN STRUCTURAL FRAMING PRODUCTS technical design guideMEMBER PROPERTIES & SPANS CURTAIN WALLS LOAD-BEARING WALLS JOISTS FRAMING DETAILSIN CONFORMANCE WITH: AISI S100-07 North American Specification [NASPEC] with 2010 supplement International Building Code [IBC] 2012 THE FUTURE OF STEEL FRAMINGTAKES FORM Clark Dietrich STRUCTURAL STEEL FRAMING SYSTEMS1 product information 3 General notes 4 Physical & STRUCTURAL properties 5-16 Overview 5-6 Stud/Track properties 7-16 Stud shear & track shear 17 Allowable stud shear 17 Allowable track shear 17 Allowable wall heights 18-38 Interior wall heights 19-25 Exterior curtain wall overview 26 Curtain wall heights 27-38 Allowable axial & lateral loads 39-58 Overview 40 Allowable combined axial & lateral loads 41-54 Allowable unbraced axial loads 55-59 Heavy-Duty Stud (HDS )

contains information on the company, its products and a wealth of other information related to the steel framing industry. This website also provides you with more detailed information about all of the company’s products, including

Tags:

  Product

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of COLD-FORMED STRUCTURAL FRAMING PRODUCTS technical …

1 STRONGER THAN STRUCTURAL FRAMING PRODUCTS technical design guideMEMBER PROPERTIES & SPANS CURTAIN WALLS LOAD-BEARING WALLS JOISTS FRAMING DETAILSIN CONFORMANCE WITH: AISI S100-07 North American Specification [NASPEC] with 2010 supplement International Building Code [IBC] 2012 THE FUTURE OF STEEL FRAMINGTAKES FORM Clark Dietrich STRUCTURAL STEEL FRAMING SYSTEMS1 product information 3 General notes 4 Physical & STRUCTURAL properties 5-16 Overview 5-6 Stud/Track properties 7-16 Stud shear & track shear 17 Allowable stud shear 17 Allowable track shear 17 Allowable wall heights 18-38 Interior wall heights 19-25 Exterior curtain wall overview 26 Curtain wall heights 27-38 Allowable axial & lateral loads 39-58 Overview 40 Allowable combined axial & lateral loads 41-54 Allowable unbraced axial loads 55-59 Heavy-Duty Stud (HDS )

2 & opening FRAMING systems 60-65 Overview 61-62 RedHeader RO 63 Opening sizing sheets 65 Floor joist FRAMING 66-96 Overview 67 Floor joist span tables 68-91 Allowable web crippling loads 92-95 Overview 93 Allowable web crippling loads single members 94 Allowable web crippling loads built-up members 95 Reference 96-103 Fastening options 97 Typical construction details 98-101 Support tools 102 LEED information and requirements 103 Material certification 104 Manufacturing and sales locations 104 While this document is quite comprehensive, it does not completely cover our vast and growing lineup of PRODUCTS .

3 You will find more complete information on each member selection, as well as nonstandard PRODUCTS , at product Submittals? Use SubmittalPro at help with product selection, ordering, scheduling, delivery, or anything else? Call us at 800-543-7140, or on the West Coast at the applications are many. But when you add in the product scope, design innovations and technical expertise that a company like ClarkDietrich alone can provide, the opportunities before you take on an entirely new to our long history and core competency in steel FRAMING , we can provide an unparalleled level of in-depth knowledge not only to help you meet the codes, but to surpass expectations for cost-effective, high-performance solutions in today s commercial and residential publication is specifically designed to help you as a contractor, engineer or architect find the right steel FRAMING components for your projects. What s more, we ve worked to make this the industry s most comprehensive technical support document for COLD-FORMED steel s exactly the kind of resource you d expect from a partner like ClarkDietrich.

4 Yes, we re known as a manufacturer of extensively tested, code-compliant steel FRAMING PRODUCTS . But we also offer PRODUCTS that perform as a system, we support a range of efforts for smarter installation and design, and we provide the expertise of a versatile engineering services team and all on a nationwide the following pages, you will find ample information, data and notes to reliably guide your decisions. But please feel free to contact us at any time for additional clarity or properties of COLD-FORMED steel are impressive ,TABLE OF CONTENTSTABLE OF CONTENTS2 How to identify our has adopted standard nomenclature established by the American Iron and Steel Institute (AISI) for identifying each of its PRODUCTS . Coding of each member consists of four parts, in this order: A number which identifies the web depth of the member to two decimal places. 600 = ," 1000 = ," 550 = ," 362 = ," etc. A letter that tells you the type of member, such as S = Stud/joist, T = Track, U = U-channel, and F = Furring channel.

5 A number that defines the flange dimension in inches to two decimal places. 162 = ," 200 = ," 125 = ," etc. A number following a hyphen that denotes the minimum delivered thickness in mils (33mils = 33/1000 inches which is approximately "). Minimum delivered thickness is 95% of design thickness. 362 S 162 43 (33ksi, CP60) PunchedProtective CoatingStructural FRAMING CP60 (G90 available) PunchingPunched studs or joists will be supplied unless the customer indicates unpunched material is required at time of order. All track and channels are = STRUCTURAL stud or joistT = STRUCTURAL trackU = CRC or U-channelF = Furring channelProduct PRODUCTS manufactured by ClarkDietrich are readily available in all markets, but there can be exceptions. Please contact your ClarkDietrich Sales Representative to make sure the product you need is available in your market FRAMING PRODUCTS are available with a variety of protective coatings that meet the CP60 coating protection level requirements of AISI S200 and ASTM C955.

6 These coatings may include G60, A60, AZ50 or GF30, all of which satisfy the above referenced standards. G90 coatings are an enhanced option that can be requested for highly corrosive environments. ClarkDietrich can supply a specific or enhanced coating to meet specific project requirements when requested. The buyer is solely responsible to assure that product is ordered to properly satisfy the applicable code or INFORMATION3 Example: 362S162-43 (33ksi, CP60) punchedClarkDietrich thickness identification and color codingClarkDietrich STRUCTURAL member depths, flanges & available thicknessMember Flange Mils Gaugedepths widths range range range (250) 2-1/2" 1-3/8," 1-5/8," 2" & 2-1/2" 33 68 20 14 ga(350) 3-1/2" 1-3/8," 1-5/8," 2" & 2-1/2" 33 68 20 14 ga(362) 3-5/8" 1-3/8," 1-5/8," 2" & 2-1/2" 33 97 20 12 ga(400) 4" 1-3/8," 1-5/8," 2" & 2-1/2" 33 97 20 12 ga(550) 5-1/2" 1-5/8," 2" & 2-1/2" 33 97 20 12 ga(600) 6" 1-3/8," 1-5/8," 2," 2-1/2" & 3" 33 97 20 12 ga(800) 8" 1-3/8," 1-5/8," 2," 2-1/2" & 3" 33 97 20 12 ga(925) 9-1/4" 1-5/8," 2" & 2-1/2" 43 97 18 12 ga(1000) 10" 1-5/8," 2," 2-1/2" & 3" 43 97 18 12 ga(1200) 12" 1-5/8," 2," 2-1/2" & 3" 54 97 16 12 ga(1400)

7 14" 1-5/8," 2," 2-1/2" & 3" 54 97 16 12 gaOld stud/track designationsOld designation Type Flange/leg CWN Stud 1-3/8"CSJ Stud 1-5/8"CSW Stud 2"CSE Stud 2-1/2"CSS Stud 3"TSB Track 1-1/4"TSC Track 2"TSE Track 3"2-1/2" widestuds3-5/8" andwider3/4"1-1/2"4"2"C-StudFlangeWebLip /returnClarkDietrich is a proud member of the Steel FRAMING Industry Association (SFIA).1 Minimum thickness represents 95% of the design thickness and is the minimum acceptable thickness delivered to the jobsite based on section of AISI S100-2007 with 2010 33mil (20ga) and 43mil (18ga) FRAMING PRODUCTS are produced with 33ksi steel. 54mil (16ga), 68mil (14ga) and 97mil (12ga) PRODUCTS are produced with 50ksi steel unless otherwise noted. Designation thickness (mils)Thickness (gauge)Design thickness (in)Minimum thickness1 (in)Color return lip dimensionsFlange Return Member width lip depths 137 (1-3/8") 3/8" 3-5/8" 8"162 (1-5/8") 1/2" 2-1/2" 14"200 (2") 5/8" 3-5/8" 14"250 (2-1/2") 5/8" 3-5/8" 14"300 (3") 5/8" 6" 14"Yield Strength (Fy)33ksi or 50ksi steel (See note 2 below)Support toolsCatalog notesTechnical Service is the most important way we serve our present and prospective customers.

8 After all, your experience with our PRODUCTS will only be a good one if you are satisfied that the material is right for the job and that it is being installed correctly. That s why we have provided four ways to make sure you can get the technical Service you support contains information on the company, its PRODUCTS and a wealth of other information related to the steel FRAMING industry. This website also provides you with more detailed information about all of the company s PRODUCTS , including load and limiting heights tables for member sizes and configurations not contained in this printed manual. Please visit this site to familiarize yourself with what we have to software To make sure you design structures successfully, we provide engineering software FREE to customers, engineers, architects and students. This state-of-the-art and user-friendly software helps configure exterior curtain wall FRAMING for wind loads, load-bearing FRAMING for combined loads, joists for required spans and anticipated load configurations, etc.

9 A download is available from our Engineering Services A full-service design and engineering firm that provides certified engineering shop drawing packages. ClarkDietrich Engineering Services is licensed throughout the United States and can be reached by calling technical Services For general technical service on PRODUCTS , member sizing, industry standards, FRAMING details or information on engineering software, please call technical services at specification time, project specifications can become outdated. For suggestions on how to improve the performance of your specifications, contact us about a complimentary review at 330-372-5564, ext. NOTES4 Standards and members comply with ASTM standards shown in the Material Certification at the back of this catalog. All STRUCTURAL properties are developed in accordance with the American Iron and Steel Institute s Specification for the Design of COLD-FORMED Steel STRUCTURAL Members, S100-07 with 2010 supplement.

10 General data contained in this catalog is intended to be used as a general guideline only and does not replace the judgment and designs of a qualified architect and/or engineer. product , application renderings and photographs are provided as a tool to show the general intent of the FRAMING or finishing application only. These renderings or photographs may or may not be applicable to a specific project. They do not replace or supercede the architect or engineer of record, ASTM guidelines, national or local building codes, or approved industry reserves the right to change or modify the information contained in this catalog without prior notice or obligation. The information in this catalog supercedes all previously published data. PRODUCTS and systems may be improved and/or changed after this catalog is PRODUCTS described here may not be available in all geographic markets. Consult your local sales office for ClarkDietrich warrants that all PRODUCTS are free from defect at time of shipment, and are manufactured in accordance with company and/or industry standards as applicable.