Commercial Gas Water Heaters

Page 1 of 6 AOSCG10210 Commercial Gas Water Heaters April 2017 A. O. Smith Corporation. All Rights | 800-527-1953 Toll-Free USA | A. O. Smith Corporation | 500 Tennessee Waltz Parkway | Ashland City, TN 37015 INTELLIGENT CONTROL SYSTEM WITH LCD DISPLAY AND iCOMM CONNECTIVITY Exclusive A. O. Smith designed touch display control system Provides detailed Water heater status information Precise temperature control adjustable from 90 to 180 degrees Built-in diagnostics Run history information Cyclone Mxi Modulating Water Heaters are compatible with the iCOMM remote monitoring system. Call for information. COMING SPRING 2017 Remote monitoring capability utilizing the iCOMM app. Wi-Fi connectivity kit requited for models 120-250, standard on models COMBUSTION CHAMBER, WITH HELICAL HEAT EXCHANGER COIL Positioned in center of tank, surrounded by Water to virtually eliminate radiant heat loss from chamber Direct spark ignition Spiral heat exchanger keeps hot burner gases swirling, uses centrifugal force to maximize efficiency of heat transfer to

Commercial Gas Water Heaters Electrical characteristics-120V-60Hz A.C., 5.0 A “A” in model represents ASME construction Propane gas models available Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. Model Number Approx. Capacity Dimensions lb/kg Approx. Shipping ...

Tags:

  Propane, Propane gas

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Commercial Gas Water Heaters

1 Page 1 of 6 AOSCG10210 Commercial Gas Water Heaters April 2017 A. O. Smith Corporation. All Rights | 800-527-1953 Toll-Free USA | A. O. Smith Corporation | 500 Tennessee Waltz Parkway | Ashland City, TN 37015 INTELLIGENT CONTROL SYSTEM WITH LCD DISPLAY AND iCOMM CONNECTIVITY Exclusive A. O. Smith designed touch display control system Provides detailed Water heater status information Precise temperature control adjustable from 90 to 180 degrees Built-in diagnostics Run history information Cyclone Mxi Modulating Water Heaters are compatible with the iCOMM remote monitoring system. Call for information. COMING SPRING 2017 Remote monitoring capability utilizing the iCOMM app. Wi-Fi connectivity kit requited for models 120-250, standard on models COMBUSTION CHAMBER, WITH HELICAL HEAT EXCHANGER COIL Positioned in center of tank, surrounded by Water to virtually eliminate radiant heat loss from chamber Direct spark ignition Spiral heat exchanger keeps hot burner gases swirling, uses centrifugal force to maximize efficiency of heat transfer to Water in tank Spiral heat exchanger reduces lime scale from forming on Water -side surfaces.

2 Which maintains energy efficiency over timePOWERED ANODES STANDARD ON ALL MODELS Provides long-lasting tank protection in varying Water conditions Powered anodes are non-sacrificial Automatically adjusts output needed to properly protect the tankCYCLONE Mxi MODULATINGMODULATING BURNER ADVANCES THE CYCLONE TO HIGHER LEVELS OF EFFICIENCYThe full line of A. O. Smith Cyclone Mxi condensing Water Heaters has been designed to provide years of dependable service and feature industry leading technology. Models are available from 120,000 to 500,000 Btu/h and all deliver thermal efficiencies of 95% and higher. The unique helical coil heat exchanger limits weld joints for optimal service life while maximizing heat is the industry leader in high efficiency Commercial Water heating.

3 The current Mxi modulating models adjust firing rate to the specific demand further increasing efficiency and money ULTRA COAT GLASS LINING Glass coating is applied using a liquid slush coating technique to ensure uniform coating Heat exchanger coil is glassed both externally and internally for optimum protectionMECHANICAL VENTING VERSATILITY Conventional power venting or direct venting Vents vertically or through a sidewall Front located exhaust and condensate connections allow for easy install and access Vents with low cost PVC Schedule 40 intake and exhaust pipe. Approved for optional CPVC Schedule 40, Polypropylene and AL29-4C stainless steel vent materials Direct-vent intake and exhaust pipe can terminate separately outside building or through single opening, using concentric vent assembly Canadian installations require ULC S636 PVC/CPVC, ULC S636 Polypropylene and AL29-4C stainless steel pipe for intake and exhaustHIGH EFFICIENCY MODULATING PRE-MIX POWERED BURNER Down-fired pre-mix burner provides optimum efficiency and quiet operation Top-mounted burner position prevents condensation from affecting burner operation3-YEAR LIMITED TANK / 1-YEAR LIMITED PARTS WARRANTY For complete warranty information, consult written warranty or go to (A)

4 THROUGH BTH-500(A) MODEL SHOWN: BTH-199(A) SERIES 300/301 Page 2 of 6 AOSCG10210 Commercial Gas Water HeatersNumber of 90 Elbows Installed3 Inch Pipe4 Inch PipeMaximum Feet (Meters)Maximum Feet (Meters)One (1)45 feet ( meters)115 feet (35 meters)Two (2)40 feet ( meters)110 feet ( meters)Three (3)35 feet ( meters)105 feet (32 meters)Four (4)30 feet ( meters)100 feet ( meters)Five (5)N/A95 feet (29 meters)Six (6)N/A90 feet ( meters)Number of 90 Elbows Installed4 Inch Pipe6 Inch PipeMaximum Feet (Meters)Maximum Feet (Meters)One (1)65 feet ( meters)115 feet (35 meters)Two (2)60 feet ( meters)110 feet ( meters)Three (3)55 feet ( meters)105 feet (32 meters)Four (4)50 feet ( meters)100 feet ( meters)Five (5)45 feet ( meters)

5 95 feet (29 meters)Six (6)40 feet ( meters)90 feet ( meters)Model NumberManifold PressureMinimum Supply PressureMaximum Supply PressureNatural GasPropane GasNatural GasPropane GasNatural GasPropane GasBTH-120(A)0" (0 kPa)0" (0 kPa) " ( kPa) " ( kPa)14" ( kPa)14" ( kPa)BTH-150(A)0" (0 kPa)0" (0 kPa) " ( kPa) " ( kPa)14" ( kPa)14" ( kPa)BTH-199(A)0" (0 kPa)0" (0 kPa) " ( kPa) " ( kPa)14" ( kPa)14" ( kPa)BTH-250(A)0" (0 kPa)0" (0 kPa) " ( kPa) " ( kPa)14" ( kPa)14" ( kPa)BTH-300(A)0" (0 kPa)0" (0 kPa) " ( kPa) " ( kPa)14" ( kPa)14" ( kPa)BTH-400(A)0" (0 kPa)0" (0 kPa) " ( kPa) " ( kPa)14" ( kPa)14" ( kPa)BTH-500(A)0" (0 kPa)0" (0 kPa) " ( kPa) " ( kPa)14" ( kPa)14" ( kPa)VENT REQUIREMENTS FOR BTH 120(A) - 250(A)VENT REQUIREMENTS FOR BTH 300(A) - 500(A) GAS PRESSURE REQUIREMENTSOTHER FEATURES:SPACE-SAVING DESIGN FOR INSTALLATION FLEXIBILITY Easy-to-remove top cover for convenient access to serviceable parts 0 installation clearances on sides and rear, 1-1/2 installation clearance on top Handhole cleanout allows easy access to tank interior for cleaning 0 clearance to combustibles, approved for installation on combustible floorsCODES AND STANDARDS CSA certified and ASME rated T&P relief valve Maximum hydrostatic working pressure: 160 psi All models are design certified by Underwriters Laboratories (UL), Inc.

6 , to ANSI - CSA Standards Meets the thermal efficiency and standby loss requirements of the Department of Energy and current edition ASHRAE/IES Design Certified by Underwriters Laboratories to NSF standard 5 for 180 F (62 C) Water Complies with SCAQMD Rule and other Air Quality Management Districts with similar requirements for ultra low-NOx emissions ASME tank construction optional on 120-500 model sizesDepending on the installed equivalent length, and/or the number of appliances connected, the supply gas line size may need to be increased beyond the minimum required 3 of 6 AOSCG10210 Commercial Gas Water HeatersElectrical characteristics-120V-60Hz , A A in model represents ASME constructionPropane gas models availableDimensions and specifications subject to change without notice in accordance with our policy of continuous product NumberApprox.

7 CapacityDimensions lb/kgApprox. Shipping Weight Std Approx. Shipping Weight ASMEABCDEFGHIJBTH-120(A)Gallons6055 1/235 27 3/4 6 5/163 42 1/411 1/448 1/253 1/218 1 (A)Gallons10076 1/256 3/827 3/4 6 5/163 64 11 1/470 75 1/218 1 (A)Gallons10076 1/256 3/827 3/4 6 5/163 64 11 1/470 75 1/218 1 (A)Gallons10076 1/256 3/827 3/4 6 5/163 64 11 1/470 75 1/218 1 120-250 ALL MODELS* Center line of Water outlet on top of the Water Heaters is approximately 7 inches from the front edge of the Water VIEWFRONTVENTCONNECTION3 INCH(exhaust elbow)AT & P VALVEBGJSUPPLY GASCONNECTIONCCLEANOUT3/4 NPTDRAIN3/4 NPTRECIRCULATIONRETURN1 1/2 NPTWATERINLETLOWERTEMPERATUREPROBEINTAKE AIRCONNECTION3 INCH PVCHWATEROUTLETHEIGHTDEIF45 30 GASCLEAN OUTT&P VALVEDRAINVALVEFRONT1 " NPT WATEROUTLETEXHAUSTAIR INTAKE18 42 26 90 BACKPage 4 of 6 AOSCG10210 Commercial Gas Water HeatersElectrical characteristics-120V-60Hz , A A in model represents ASME constructionPropane gas models availableDimensions and specifications subject to change without notice in accordance with our policy of continuous product NumberApprox.

8 CapacityDimensions lb/kgApprox. Shipping Weight Std Approx. Shipping Weight ASMEABCDEFGHIJBTH-300(A)Gallons11975 3/452 33 1/84 3/44 3/463 1/812 3/469 1/474 1/223 (A)Gallons11975 3/452 33 1/84 3/44 3/463 1/812 3/469 1/474 1/223 (A)Gallons11975 3/452 33 1/84 3/44 3/463 1/812 3/469 1/474 1/223 300-500 GASINTAKECLEANOUTT&PDRAINEXHAUST1 1/2" NPTWATEROUTLETFRONT 18 30 45 42 70 20 TOPRECIRC RETURNCLEANOUT3/4" NPTT&P3/4" NPT DRAIN1 1/2" NPT Water INLET 75-3 " EXHAUST VENTCONNECTIONCONNECTION1 1/2" SUPPLY GASBACK4" PVC AIR INTAKECONNECTION74-1/2 in33-1 -1 1/2" NPTWATEROUTLETFRONT 18 30 45 42 70 20 TOPRECIRC RETURNCLEANOUT3/4" NPTT&P3/4" NPT DRAIN1 1/2" NPT Water INLET 75-3 " EXHAUST VENTCONNECTIONCONNECTION1 1/2" SUPPLY GASBACK4" PVC AIR INTAKECONNECTION74-1/2 in33-1 -1 Gas Water HeatersPage 5 of 6 AOSCG10210 GAS LINE CONNECTION SIZESTORAGE CAPACITYRECOVERY CAPACITYM odel SeriesNatural GasPropane GasBTH

9 120300/3013/4" NPT 3/4" NPT BTH 150300/3013/4" NPT 3/4" NPT BTH 199300/3013/4" NPT 3/4" NPT BTH 250300/3013/4" NPT 3/4" NPT BTH 300300/3011-1/2" NPT1-1/2" NPTBTH 400300/3011-1/2" NPT1-1/2" NPTBTH 500300/3011-1/2" NPT1-1/2" NPTM odel NumberType of GasInput Thermal EfficiencyBTU/HRkWBTH-120(A)Natural/Prop ane120,0003595%BTH-150(A)Natural/ propane 150,0004498%BTH-199(A)Natural/Propane199 ,9005897%BTH-250(A)Natural/Propane250,00 07396%BTH-300(A)Natural/Propane300,00088 96%BTH-400(A)Natural/Propane399,90011795 %BTH-500(A)Natural/Propane499,90014695%M odel GALLONS/HR AND LITRES/HR AT TEMPERATURE RISE INDICTATED Approx. Capacity F30 F40 F50 F60 F70 F80 F90 F100 F110 F120 F130 F140 F C17 C22 C28 C33 C39 C44 C50 C56 C61 C67 C72 C78 CBTH-120(A)60 LitresLPH1743130810468727476545815234754 36402374 BTH-150(A)100 LitresLPH2248168613491124963843749674613 562519482 BTH-199(A)100 LitresLPH2965222417791483127111129888908 09741684635 BTH-250(A)100 LitresLPH3670275322021835157313761223110 11001918847786 BTH-300(A)119 LitresLPH4405330426432202188816521468132 1120111011017944 BTH-400(A)119 LitresLPH5810435834862905249021791937174 31585145313411245 BTH-500(A)

10 119 LitresLPH7263544843583632311327242421217 91981181616761556 Model GallonsLitersBTH 12060227 BTH 150100379 BTH 199100379 BTH 250100379 BTH capacities are based on AHRI rated thermal ASME Construction add an A to the end of the model number ex: Technical Information, call 800-527-1953. A. O. Smith Corporation reserves the right to make product changes or improvements without prior Gas Water HeatersPage 6 of 6 AOSCG10210 April A. O. Smith Corporation. All Rights | 800-527-1953 Toll-Free USA | A. O. Smith Corporation | 500 Tennessee Waltz Parkway | Ashland City, TN 37015 SPECIFICATION(Natural or propane ) gas Water heater(s) shall be A. O. Smith Cyclone Mxi model # _____ or equal, minimum 95% thermal efficiency, a storage capacity of _____ gallons, an input rating of _____ BTUs per hour, a recovery rating of _____ gallons per hour (gph) at 100 F rise and a maximum hydrostatic working pressure of 160 psi.