Example: dental hygienist

CompactLogix 5370 L3 Controllers Quick Start

CompactLogix 5370 L3 ControllersCatalog Numbers 1769-L30ER, 1769-L30 ERM, 1769-L30ER-NSE, 1769-L33ER, 1769-L33 ERM, 1769-L36 ERMQ uick StartImportant User InformationSolid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication available from your local rockwell automation sales office or online at ) describes some important differences between solid-state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the wide variety of uses for solid-state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is no event will rockwell automation , Inc.

6 Rockwell Automation Publication IASIMP-QS023B-EN-P - December 2012 Where to Start Sample Panel Layout The sample panel layout shows the orientation of an example CompactLogix 5370 L3 control system using EtherNet/IP …

Tags:

  Controller, System, Control, Automation, Rockwell automation, Rockwell, 7350, Control system, Compactlogix, Compactlogix 5370 l3 controllers

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of CompactLogix 5370 L3 Controllers Quick Start

1 CompactLogix 5370 L3 ControllersCatalog Numbers 1769-L30ER, 1769-L30 ERM, 1769-L30ER-NSE, 1769-L33ER, 1769-L33 ERM, 1769-L36 ERMQ uick StartImportant User InformationSolid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication available from your local rockwell automation sales office or online at ) describes some important differences between solid-state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the wide variety of uses for solid-state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is no event will rockwell automation , Inc.

2 Be responsible or liable for indirect or consequential damages resulting from the use or application of this examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, rockwell automation , Inc. cannot assume responsibility or liability for actual use based on the examples and patent liability is assumed by rockwell automation , Inc. with respect to use of information, circuits, equipment, or software described in this of the contents of this manual, in whole or in part, without written permission of rockwell automation , Inc.

3 , is this manual, when necessary, we use notes to make you aware of safety , CompactLogix , ControlFLASH, Kinetix, Logix5000, PanelView, POINT I/O, PowerFlex, rockwell Software, rockwell automation , RSLinx, RSNetWorxStratix 6000, Studio 5000, and TechConnect are trademarks of rockwell automation , not belonging to rockwell automation are property of their respective : Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic : Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss.

4 Attentions help you identify a hazard, avoid a hazard, and recognize the HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous voltage may be HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may reach dangerous information that is critical for successful application and understanding of the automation Publication IASIMP-QS023B-EN-P - December 20123 Where to StartFollow the path that matches your hardware and network BNET ASTSC reate a Logix Designer ProjectPrepare the CompactLogix 5370 L3 controller HardwarePrepare the Computer and Load controller FirmwareConfigure the EtherNet/IP NetworkConfigure the DeviceNet NetworkRequiredRequiredOptionalRequiredp age 17page 33page 49page 53page 63 OptionalPOINT I/O ModulesKinetix 350 DrivePowerFlex 40 DrivePowerFlex 70

5 DrivePanelView Plus TerminalFor more information on using each optional device, see Table 1 on page automation Publication IASIMP-QS023B-EN-P - December 2012 Where to StartHow Hardware Is ConnectedThis Quick Start , in use with the additional Quick starts listed in Ta b l e 1 o n p a g e 1 2, describes possible control systems shown in Figure 1 and Figure 2. Figure 1 - CompactLogix 5370 L3 controller in a Star Network TopologyPORTMODNET BNET ASTS1 (Front)1 (Front)1 (Front)2 (Rear)12345678 Kinetix 350 DriveStratix 6000 SwitchCompactLogix 5370 L3 control SystemPowerFlex 70 Drive with 20-COMM-E AdapterPowerFlex 40 Drive with 22-COMM-E AdapterPanelView Plus Terminal with Built-in EtherNet/IP PortComputerDistributed POINT I/O Modules with 1734-AENT AdapterStar Network TopologyApplication ConfigurationRockwell automation Publication IASIMP-QS023B-EN-P - December 20125 Where to StartFigure 2 - CompactLogix 5370 L3 Controllers Using a DeviceNet Network1 (Front)2 (Rear)

6 PowerFlex 70 Drive with 20-COMM-D AdapterPowerFlex 40 Drive with 22-COMM-D AdapterComputer with 1784-U2DN CableDistributed POINT I/O Modules with 1734-ADN Adapter1606-XLDNET4 DeviceNet Power SupplyCompactLogix 5370 L3 control system with 1769-SDN ModuleApplication ConfigurationRSNetWorx for DeviceNet Software Configuration6 rockwell automation Publication IASIMP-QS023B-EN-P - December 2012 Where to StartSample Panel LayoutThe sample panel layout shows the orientation of an example CompactLogix 5370 L3 control system using EtherNet/IP networks and DeviceNet specific layout of CompactLogix 5370 L3 control systems varies by application.

7 The following graphic is an example panel layout. The graphic shows a PowerFlex 40 drive used on a DeviceNet network. You can also use a PowerFlex 40 drive on an EtherNet/IP network. 1 (Front)1 (Front)1 (Front)2 (Rear)AC Line FilterPowerFlex 70 DrivePowerFlex 40 DriveKinetix 350 DriveLine Interface ModuleDeviceNet Power SupplyDeviceNet KwikLink SystemCompactLogix 5370 L3 control SystemEthernet SwitchDistributed POINT I/O ModulesThrough-the-door DisconnectPanelView Plus TerminalE-Stop Push ButtonRockwell automation Publication IASIMP-QS023B-EN-P - December 20127 Table of ContentsPrefaceAbout the CompactLogix L3 Controllers .

8 10 Choose to Integrate Optional Devices .. 12 Studio 5000 Environment .. 13 Required Software .. 14 Parts List .. 15 Additional Resources .. 16 Chapter 1 Prepare the CompactLogix 5370 L3 controller HardwareBefore You Begin .. 17 What You Need .. 18 Follow These Steps .. 19 Install the Networks .. 20 Install the Secure Digital Card .. 21 Assemble the system .. 23 Make Network Connections .. 26 Make USB Connection .. 27 Make an EtherNet/IP Network Connection.. 28 Make a DeviceNet Network Connection (Optional) .. 29 Wire Power.. 32 Chapter 2 Prepare the Computer and Load controller FirmwareBefore You Begin.

9 33 What You Need .. 34 Follow These Steps .. 35 Install the Studio 5000 Environment .. 36 Automatic Installation of ControlFLASH Software.. 38 Configure an EtherNet/IP Driver in RSLinx Classic Software .. 38 Set the IP Address for the Computer.. 41 Load the controller Firmware .. 44 Install Additional Software .. 48 Chapter 3 Configure the EtherNet/IP NetworkBefore You Begin .. 50 What You Need .. 51 Assign an IP Address to the controller Over a USB Connection .. 518 rockwell automation Publication IASIMP-QS023B-EN-P - December 2012 Table of ContentsChapter 4 Configure the DeviceNet NetworkBefore You Begin.

10 53 What You Need .. 54 Follow These Steps .. 55 Apply Power to the DeviceNet Network .. 56 Set the 1769-SDN Module s Node Address .. 57 Create a DeviceNet Configuration File .. 59 Chapter 5 Create a Logix Designer ProjectBefore You Begin .. 64 What You Need .. 64 Follow These Steps .. 65 Create a Project .. 66 Configure the controller .. 68 Add Local I/O Module .. 70 Add the 1769-SDN to the Project .. 71 Add Ladder Logic to Test the Local 1769-OB16 Module .. 73 Download to the controller and Test the Logic .. 76 Appendix AUnderstanding Other Application OptionsDLR Network Topology .. 80 Follow These Steps.