Example: barber

COMPONENT CATALOGUE FOR - KLH: Home

C O M PO N E N T C A TA L O G U E F O R C R O S S L A M I N A T E D T I M B E R S T R U C T U R E S KLH Massivholz GmbHPublisher and responsible for the content: KLH Massivholz GmbHVersion: 01/2011, COMPONENT CATALOGUE for Cross laminated timber StructuresThe content of this brochure is intellectual property of the company and is protected by copyright. The statements are recommendations and proposals only; a liability on the part of the publisher is excluded. Any type of reproduction is strictly forbidden and only permitted after written approval of the M P R I N T0101 W a l l- C o nC r e t e C o n n eC t i o n 0 40 2 W a l l- W a l l C o n n eC t i o n , C e i l i n g - W a l l C o n n eC t i o n 0 60 3 W a l l- W a l l C o n n eC t i o n , r o o f - W a l l C o n n eC t i o n 070 4

01 WALL-CONCRETE CONNECTION 1.1 Without additional sill plate KLH wall panel according to static requirements E.g. BMF angle bracket Shear transmission and tension anchorage for

Tags:

  Component, Shares, Catalogue, Tension, Component catalogue for

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of COMPONENT CATALOGUE FOR - KLH: Home

1 C O M PO N E N T C A TA L O G U E F O R C R O S S L A M I N A T E D T I M B E R S T R U C T U R E S KLH Massivholz GmbHPublisher and responsible for the content: KLH Massivholz GmbHVersion: 01/2011, COMPONENT CATALOGUE for Cross laminated timber StructuresThe content of this brochure is intellectual property of the company and is protected by copyright. The statements are recommendations and proposals only; a liability on the part of the publisher is excluded. Any type of reproduction is strictly forbidden and only permitted after written approval of the M P R I N T0101 W a l l- C o nC r e t e C o n n eC t i o n 0 40 2 W a l l- W a l l C o n n eC t i o n , C e i l i n g - W a l l C o n n eC t i o n 0 60 3 W a l l- W a l l C o n n eC t i o n , r o o f - W a l l C o n n eC t i o n 070 4 ro o f -r o o f C o n n eC t i o n 0 80 5 C e i l i n g J o i n t o n W a l l 0 90 6 tr a n s v e r s e C e i l i n g J o i n t s.

2 F l e x i b l e a n d b e n d -r e s i s ta n t 1007 C e i l i n g /r o o f C o n n eC t i o n t o s u s p e n d e r b e a m 120 8 C e i l i n g /r o o f C o n n eC t i o n t o s t e e l g i r d e r 130 9 lo n g i t u d i n a l pa n e l J o i n t t r a n s v e r s e f o rC e C o n n eC t i o n s 14 10 su p p o r t o f s h e a r W a l l s s u s p e n s i o n o f C e i l i n g s 15 11 ai r t i g h t n e s s s e a l i n g l ay e r t h r o u g h C o n v eC t i o n b a r r i e r 1612 ai r t i g h t n e s s f l oW -t i g h t C o n s t r uC t i o n a l d e s i g n 1813 el eC t r iC a l i n s ta l l at i o n s 2 014 in s ta l l at i o n s l o t s a n d o p e n i n g s 21C O N T E N TI N T R O D U C T I O NThe suggested constructional designs with KLH solid wood panels show application details in a systematic and self-explanatory and planners will be able to easily derive project-specific details with reference to the basic depictions.

3 T he suggested detailed solutions merely represent recommendations given by the principle, KLH constructions may be combined with all constr uction mater ials available on the market. For example: you may use various different insulating materials such as soft wooden f ibres, mineral f ibres, cellulose, etc. as well as different fa ade materials on back-ventilated fa ades or rendered fa ades. The struc-tural and physical aspects such as sound insulation, heat insulation, air tightness of the building or fire protection must be assessed on the basis of the relevant KLH construction as such, as well as the required connections, must be dimensioned appropriately in ter ms of statics.

4 It may happen that the suggested standard connection types are not sufficient, if high earthquake loads require tension anchorage of KLH wall u ction02 A r c h i t e c t D i p l . I n g . H u b e r t R i e , K L HCon-str u ction01 WA LL- C O N CR E T E C O NNEC T I O N W i t h o u t a d d i t i o n a l s il l p l at eKLH wall panel according to static BMF angle bracketShear transmission and tension anchorage for the walls according to static requirementsLow -shrink mor tar bedConcrete COMPONENT (wall, ceiling, concrete slab)Caution: At least 2 dowels must be installed for each BMF angle bracket.

5 Other wise the ef fect of the angle bracket is highly reduced (preferably use the t wo holes directly nex t to the wall or the sill plate)Caution: At least 2 dowels must be installed for each BMF angle bracket; other wise the ef fect of the angle bracket is highly reduced (preferably use the t wo holes directly nex t to the wall or the sill plate)The walls must rest on the base over their entire leng th if the walls only rest on the base in some places, static verification is required1. 2 W i t h t hin s il l p l at eInstall joint tape, if necessar yProtection against rising moistureConcrete COMPONENT (wall, ceiling, concrete slab)

6 KLH wall panel according to static BMF angle bracket for shear and tensile forces special solutions are required for high tensile forcesOak or larch sill laid in mor tar bed with the entire sur face resting on the base557766443311225566644331122W A L L - C O N C R E T E C O N N E C T I O N 0 W i t h hi g h s il l p l at eKLH wall panel according to static requirementsConcrete COMPONENT (wall, ceiling, concrete slab)2 x sealing tape along longitudinal panel C o nneCt i o n o f t hiCKe r e x t e r i o r Wa l l sOak or larch sill laid in mor tar bed with the entire sur face resting on the baseDiagonal fully threaded screws to absorb higher horizontal forcesInstall joint tape.

7 If necessar BMF perforated plate for shear connection bet ween KLH wall and sillSill plate laid in mor tar bed and dowelled to concreteConcrete screws for shear force transmission bet ween sill and concreteDowel connection bet ween sill andconcrete55664444333311112222W A L L - C O N C R E T E C O N N E C T I O N 0502 WALL-WALL CONNECTION, CEILING -WALL CONNECTIONS hear force transmission along the joint and tension anchorage of walls BMF angle bracket t ype, distance according to static BMF angle bracket for the statically effective connection between wall and ceiling.

8 Shear forces in the direction of the wall, tension and pressure normal to the wall (wind forces)Install joint tape for all panel joints, unless a vapour barrier or windproof layer is installed on the outsideCeiling /walls screw connection with self- drilling wood screws t ype, diameter and distance according to static require-mentsCorner joint screw connection of wall corners according to static requirements or for the compression of joint tapesScrew connection of ceiling with walls according to static requirementsCross wall connection screw connection from the insideCross wall connection screw connection from the outsideKLH panel according to static e x t e r i o r Wa l l in t e r i o r Wa l l - Ce il in g2.

9 2 e x t e r i o r Wa l l e x t e r i o r Wa l l - Ce il in g4445533112243112223W A L L - W A L L C O N N E C T I O N , C E I L I N G - W A L L C O N N E C T I O N0 603 WA LL- WA LL C O NNEC T I O N , R O O F - WA LL C O NNEC T I O NThe screws only transfer shear forces in the direction of the joints; mind the reduced bedding leng thsBevelled panel edges can only be easily produced up to approx. 20 cm of bevelled leng thScrews absorb shear forces parallel to bearing or wind suction forcesUse fully threaded screws for high forces towards theinsideThe bearing sur face must be set at a normal angle in the direction of the main loadsIf the main bearing direction of the panel is parallel to the bearing, any lateral projections are only possible subject to cross - bearing capacities (middle layers)

10 Static verification requiredRequired edge distances for the screwsShiplap design if high shear forces must be C o nneCt i o ns o f Wa l l s at a n a n g l e toWa r d s e aCh ot he r3. 2 e av e s d e s i g n Wi t h C a n o p y o r in t e r me d i at e b e a r in g ( mid d l e Wa l l) e av e s d e s i g n Wi t h o u t C a n o p y (ind e p e nd e n t o f pa ne l b e a r in g d ir eCt i o n)For ver y shallow angles, the ef fectiveness of screw connections is quite limited; special measures might become necessar y5312544433311112224W A L L - W A L L C O N N E C T I O N , R O O F - W A L L C O N N E C T I O N0 70 4 R O O F - R O O F C O NNEC T I O NMain bearing direction of the panelMain bearing direction of the panelTransverse forcesScrew connection mainly transfers shear forces in a longitudinal direction, only minor transverse forcesThe transverse forces of this joint design are higher than for bevelled panel edgesIf panels are thinner, it may not be possible to transfer forces with screws (cross tension )


Related search queries