Example: bachelor of science

Components - MMG Canada Ltd.

ETD SeriesComponentsETD SeriesComponentsETD CoresETD (Economical Transformer Design) cores were developed specifically for Power Transformer coresused in Switched Mode power supplies. The combined cross-sectional area of the two outer limbsequals the cross-sectional area of the centre limb allowing an even flux distribution throughout thecore. This ensures the absence of localised hot spots that can reduce performance at highfrequencies or high flux levels. Their round centre limb provides for minimal winding resistance,leakage inductance and copper eddy current Cores are available in a range of sizes and materials together with their associated coilformers(both Horizontal and Vertical mounting) and CoreCoilformerETD CoreClipETD 2932-580-ETD 2932-580-Parameter l /AEffective LengthEffective AreaMinimum

ETD Series Components ETD Cores ETD (Economical T ransformer Design) cores were developed specifically for Power Transformer coresused in Switched Mode power supplies. The combined cross-sectional area of the two outer limbs equals the cross-sectional area of the centre limb allowing an even flux distribution throughout the

Tags:

  Series, Component, Series components

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Components - MMG Canada Ltd.

1 ETD SeriesComponentsETD SeriesComponentsETD CoresETD (Economical Transformer Design) cores were developed specifically for Power Transformer coresused in Switched Mode power supplies. The combined cross-sectional area of the two outer limbsequals the cross-sectional area of the centre limb allowing an even flux distribution throughout thecore. This ensures the absence of localised hot spots that can reduce performance at highfrequencies or high flux levels. Their round centre limb provides for minimal winding resistance,leakage inductance and copper eddy current Cores are available in a range of sizes and materials together with their associated coilformers(both Horizontal and Vertical mounting) and CoreCoilformerETD CoreClipETD 2932-580-ETD 2932-580-Parameter l /AEffective LengthEffective AreaMinimum AreaEffective Core ParametersMaterialAL ValueToleranceGap LengthEff.

2 PermeabilityPart NumberF47 1800 +30/-20% - 1332 32-580-47F44 1950 +30/-20% - 1443 32-580-44F45 2000 +30/-20% - 1480 32-580-45F5A 2350 +30/-20% - 1739 32-580-49F44 800 Approx.

3 - mm 590 32-586-44F44 460 Approx. - mm 340 32-587-44F44 220 Approx. - mm 160 32-588-44F44 125 Approx. - mm 92 32-589-44 Electrical Specification Bobbins/Coil FormersMountingNo.

4 Of SectionsPinsPart NumberHorizontal11459-580-76 Vertical11259-585-76 ClipsPart Number76-055-9576-055-95 Part numbers refer to half cores. Other material grades and gap lengths may be available on accordance with IEC Standard 1185In accordance with IEC Document 60205. Core Dimensions (mm) 3432-500-ETD 3432-500-Parameter l /AEffective LengthEffective AreaMinimum AreaEffective Core ParametersMaterialAL ValueToleranceGap LengthEff. PermeabilityPart NumberF44 2250 +30/-20% - 1450 32-500-44F45 2400 +30/-20% - 1546 32-500-45F5A 2840 +30/-20% - 1830 32-500-49F44 1000 Approx.

5 - mm 645 32-506-44F44 580 Approx. - mm 375 32-507-44F44 275 Approx. - mm 175 32-508-44F44 160 Approx. - mm 100 32-509-44 Electrical Specification Bobbins/Coil FormersMountingNo.

6 Of SectionsPinsPart NumberHorizontal11459-500-76 Vertical11459-505-76 ClipsPart Number76-050-9576-050-95 Part numbers refer to half cores. Other material grades and gap lengths may be available on accordance with IEC Standard 1185In accordance with IEC Document 60205. Core Dimensions (mm) -11. -11. minETD 3932-520-ETD 3932-520-Parameter l /AEffective LengthEffective AreaMinimum AreaEffective Core ParametersMaterialAL ValueToleranceGap LengthEff. PermeabilityPart NumberF44 2470 +30/-20% - 1455 32-520-44F5A 3210 +30/-20% - 1890 32-520-49F44 1250 Approx.

7 - mm 735 32-526-44F44 720 Approx. - mm 425 32-527-44F44 350 Approx. - mm 205 32-528-44F44 200 Approx. - mm 120 32-529-44 Electrical Specification Bobbins/Coil FormersMountingNo.

8 Of SectionsPinsPart NumberHorizontal11659-520-76 Vertical11659-525-76 ClipsPart Number76-051-9576-051-95 Part numbers refer to half cores. Other material grades and gap lengths may be available on accordance with IEC Document accordance with IEC Standard 1185 Core Dimensions (mm) minETD 4432-540-ETD 4432-540-In accordance with IEC Standard 1185 Parameter l /AEffective LengthEffective AreaMinimum AreaEffective Core ParametersMaterialAL ValueToleranceGap LengthEff. PermeabilityPart NumberF44 3100 +30/-20% - 1480 32-540-44F5A 3920 +30/-20% - 1870 32-540-49F44 1670 Approx.

9 - mm 800 32-546-44F44 970 Approx. - mm 460 32-547-44F44 470 Approx. - mm 225 32-548-44F44 270 Approx. - mm 130 32-549-44 Electrical Specification Bobbins/Coil FormersMountingNo.

10 Of SectionsPinsPart NumberHorizontal11859-540-76 Vertical11859-545-76 ClipsPart Number76-052-9576-052-95 Part numbers refer to half cores. Other material grades and gap lengths may be available on accordance with IEC Document 60205. Core Dimensions (mm) minETD 4932-560-ETD 4932-560-Parameter l /AEffective LengthEffective AreaMinimum AreaEffective Core ParametersMaterialAL ValueToleranceGap LengthEff. PermeabilityPart NumberF44 3525 +30/-20% - 1515 32-560-44F5A 4400 +30/-20% - 1890 32-560-49F44 2000 Approx.


Related search queries