Example: stock market

Concrete Mix Selector Guide - QUIKRETE

Concrete Mix Selector GuideFor SPEC DATA and Guide Specification documents on all our Commercial Grade products, please visit our On the Job section at Concrete (No. 1004-51) Concrete Mix(No. 1101) QUIKRETE 5000(No. 1007-80) Crack Resistant(No. 1006)Fast-Setting(No. 1004)ASTMASTM C 387 ASTM C 387 ASTM C 387 ASTM C 387 ASTM C 928 R-3 Structural Concrete mix Normal setAttributesConcrete 4000 PSI @ 28 days 1500 PSI @ 3 daysStrengths High early strength gain 10-12 hr walk-on time 5000 PSI @ 28 days 1500 PSI @ 1 day Crack resistant air entrained Improved workability Normal set 4000 PSI @ 28 days 1500 PSI @ 3 days Sets posts without mixing Sets in 20-40 min. 4000 PSI @ 28 days Sets in 25-45 min. 7000 PSI @ 28 days 3000 PSI @ 3 hoursPatios, Sidewalks, ApronsCold Weather UseSetting PostsSetting Posts w/o MixingStepsColumnsWallsCurbsAir Conditioner PadsFloorsDeck SupportsBridge Deck RepairsConcrete Parking LotsLoading DocksRapid Structural RepairApplicationWidespread UseHigh Strength EarlierResists Cracking& SpallingSets PostWithout MixingRapid HardeningStructural Concret

Air Entrained • Improved Workability • Normal Set • 4000 PSI @ 28 days • 1500 PSI @ 3 days • Sets Posts without Mixing • Sets in 20 to 40 Min. Patios, Sidewalks, etc. Footings Driveway Aprons Cold Weather Use Setting Posts Set Posts w/o Mixing Steps Columns Walls Curbs Air Conditioner Pads Floors Deck Supports Bridge Deck ...

Tags:

  Quikrete, Entrained, Air entrained

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Concrete Mix Selector Guide - QUIKRETE

1 Concrete Mix Selector GuideFor SPEC DATA and Guide Specification documents on all our Commercial Grade products, please visit our On the Job section at Concrete (No. 1004-51) Concrete Mix(No. 1101) QUIKRETE 5000(No. 1007-80) Crack Resistant(No. 1006)Fast-Setting(No. 1004)ASTMASTM C 387 ASTM C 387 ASTM C 387 ASTM C 387 ASTM C 928 R-3 Structural Concrete mix Normal setAttributesConcrete 4000 PSI @ 28 days 1500 PSI @ 3 daysStrengths High early strength gain 10-12 hr walk-on time 5000 PSI @ 28 days 1500 PSI @ 1 day Crack resistant air entrained Improved workability Normal set 4000 PSI @ 28 days 1500 PSI @ 3 days Sets posts without mixing Sets in 20-40 min. 4000 PSI @ 28 days Sets in 25-45 min. 7000 PSI @ 28 days 3000 PSI @ 3 hoursPatios, Sidewalks, ApronsCold Weather UseSetting PostsSetting Posts w/o MixingStepsColumnsWallsCurbsAir Conditioner PadsFloorsDeck SupportsBridge Deck RepairsConcrete Parking LotsLoading DocksRapid Structural RepairApplicationWidespread UseHigh Strength EarlierResists Cracking& SpallingSets PostWithout MixingRapid HardeningStructural Concret


Related search queries