Table of Contents Multi- Conductor Cables Page No. Introduction Selection Guide: Shielded Computer Cables for RS-232 Applications Unshielded Audio, Control and Instrumentation Cables 22 AWG Non-Plenum & Plenum 20 AWG Non-Plenum 18 AWG Non-Plenum & Plenum 16 AWG Non-Plenum Multi- Conductor Cables 14 AWG Non-Plenum 22 and 18 AWG Non-Plenum 20 and 16 AWG Non-Plenum Antenna Rotor Control Cables Duplex Primary Wires Power and Control Cables Overall Beldfoil Shield 4. Computer Cables for Synchronous EIA Interface Computer Cables for EIA RS-232 Applications Audio, Control and Instrumentation Cables 22 AWG Non-Plenum 20 AWG Non-Plenum 18 AWG Non-Plenum & Plenum 16 AWG Non-Plenum Overall Braid and Special Shielding Audio, Control and Instrumentation Cables Overall Braid Shield MIL-Spec Communication & Instrumentation Cables Overall Foil/Braid Shield Computer Cables for EIA RS-232 Applications 28 AWG Non-Plenum 28 AWG Non-Plenum, Low Capacitance 26 and 24 AWG Non-Plenum, IEEE 488 24 AWG Non-Plenum 22 AWG Non-Plenum Overall Shield Special Audio, Control and Instrumentation Cables Data Cables for Molex SEMMCONN and AMP SDL Connectors Direct Burial Cables Plenum-Rated cable Unshielded Overall Beldfoil Shield Overall Foil/Braid Shield High-Temperature Control & Instrumentation cable Unshielded Overall Beldfoil Shi

PVC Insulation • Chrome PVC Jacket UL AWM Style 2576 8457 NEC: 12 See 100 30.5 5.6 2.5 .010 .25 .032 .81 .272 6.91 (150V 80°C) CMG Chart 1 U-500 U-152.4 25.5 11.6

Tags:

  Cable, Belden, Conductor, Conductor cables

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Conductor Cables - Belden

1 Table of Contents Multi- Conductor Cables Page No. Introduction Selection Guide: Shielded Computer Cables for RS-232 Applications Unshielded Audio, Control and Instrumentation Cables 22 AWG Non-Plenum & Plenum 20 AWG Non-Plenum 18 AWG Non-Plenum & Plenum 16 AWG Non-Plenum Multi- Conductor Cables 14 AWG Non-Plenum 22 and 18 AWG Non-Plenum 20 and 16 AWG Non-Plenum Antenna Rotor Control Cables Duplex Primary Wires Power and Control Cables Overall Beldfoil Shield 4. Computer Cables for Synchronous EIA Interface Computer Cables for EIA RS-232 Applications Audio, Control and Instrumentation Cables 22 AWG Non-Plenum 20 AWG Non-Plenum 18 AWG Non-Plenum & Plenum 16 AWG Non-Plenum Overall Braid and Special Shielding Audio, Control and Instrumentation Cables Overall Braid Shield MIL-Spec Communication & Instrumentation Cables Overall Foil/Braid Shield Computer Cables for EIA RS-232 Applications 28 AWG Non-Plenum 28 AWG Non-Plenum, Low Capacitance 26 and 24 AWG Non-Plenum, IEEE 488 24 AWG Non-Plenum 22 AWG Non-Plenum Overall Shield Special Audio, Control and Instrumentation Cables Data Cables for Molex SEMMCONN and AMP SDL Connectors Direct Burial Cables Plenum-Rated cable Unshielded Overall Beldfoil Shield Overall Foil/Braid Shield High-Temperature Control & Instrumentation cable Unshielded Overall Beldfoil Shield Overall Braid Shield.

2 MIL-W-16878/4 (Type E) Fire Alarm cable Please refer to Terms of Use of Master Catalog on page M U L T I - C O N D U C T O R C A B L E S Introduction Selection Guide Belden multi- Conductor Cables are manufactured in a wide Shielded Multi- Conductor Computer Cables for variety of gage sizes, dimensions, insulation materials, shielding RS-232 Applications configurations, and jacketing materials including Plenum and High-Temperature versions. These Cables meet the technical cable Series*. requirements of many different types of systems. In fact, Belden Specifications 9925 9608 9533 9939. offers one of the broadest lines of UL Listed, NEC and CEC Conductor Size: 28. multi- Conductor Cables available from any single source. (AWG) 24 . Applications for multi- Conductor Cables include computers, 22 . communications, instrumentation, sound, control, audio, and 20. data transmission.

3 Each of these Cables is designed to protect 18. signal integrity under critical conditions by reducing hum, noise, Page No. and crosstalk. Insulation: S-R PVC . To assist you in selecting the proper cable for your application, Polyethylene both the suggested working voltages and the maximum temperature ratings are indicated for each applicable product in this section. Polypropylene Datalene . Most of our multi- Conductor Cables are available from stock. Many Shield: Overall Foil . of these are available off the shelf from distributors. If you have a new or unusual application or you cannot find a multi- Conductor Drain Wire . cable in this catalog section that meets your technical requirements, Overall Foil/Braid . contact Technical Support at 1-800- Belden -1. Braid Coverage 65% 65% 65%. Drain Wire Overall: Yes No Yes No Multi- Conductor Cables Packaging No. of Cond. Available: 1.

4 2. Belden 's unique UnReel cable dispenser is available for many of 3 . the multi- Conductor products listed in this section. The letter U . 4 . before the specified put-up length denotes UnReel packaging. 5 . 6 . 7 . 8 . 9 . 10 . 11. 12. 13. 15 . 17. 18. 19. 20 . 25 . 27. 30 . 31. 37 . 40 . 50 . Capacitance ** (pF/ft.) *All Cables are UL-listed. **Capacitance may vary on some Cables . Foam high density polyethylene. F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 w w w . b e l d e n . c o m M U L T I - C O N D U C T O R C A B L E S Unshielded Audio, Control and Instrumentation Cables Non-Plenum Standard Insulation Jacket UL NEC/ No. Standard Lengths Nominal OD. Color Unit Weight Thickness Thickness Description Part No. C(UL) CEC of Code Type Cond. Ft. m Lbs. kg Inch mm Inch mm Inch mm 22 AWG Solid Bare Copper Conductors Conductors Cabled Polyethylene Insulation Rose Gray PVC Jacket UL AWM Style 2092 8795 NEC: 2 Red, U-500.

5 018 .46 .022 .56 .168 (300V 60 C) CM Green U-1000 CEC: 1000 CM. UL AWM Style 2093 8794 NEC: 3 Green, U-1000 .018 .46 .022 .56 .178 (300V 60 C) CM Red, 1000 Yellow UL AWM Style 2094 9794 NEC: 4 Green, U-500 .018 .46 .025 .64 .200 (300V 60 C) MP, CM Red, U-1000 Yellow, 1000 Black UL AWM Style 2094 1242A NEC: 4 Green, U-1000 .018 .46 .025 .64 .154 (300V 60 C) CM Red, CEC: Yellow, CM Black 22 AWG Stranded (7x30) Tinned Copper Conductors Conductors Cabled PVC Insulation Chrome PVC Jacket 8442* NEC: 2 Black, 100 .015 .38 .025 .64 .170 CMG Red U-500 4 Multi- Conductor Cables CEC: 500 For Plenum versions of 8442, CMG FT4 U-1000 see 88442 or 82442. 1000 *Twisted pair 10000 UL AWM Style 2576 8443 NEC: 3 Black, 100 .010 .25 .032 .81 .172 (150V 80 C) CMG Red, U-500 CEC: Green 500 CMG FT4 U-1000 1000 8444 NEC: 4 See 100 .010 .25 .032 .81 .185 CMG Chart 1 U-500 CEC: (Tech Info 500 For Plenum versions of 8444, CMG FT4 Section) U-1000 see 88444 or 82444.

6 1000 8445 NEC: 5 See 100 .010 .25 .032 .81 .194 CMG Chart 1 U-500 CEC: (Tech Info 500 CMG FT4 Section) U-1000 1000 9430 NEC: 7 See U-500 .010 .25 .032 .81 .214 CMG Chart 1 500 CEC: (Tech Info U-1000 CMG FT4 Section) 1000 9421 NEC: 8 See 100 .010 .25 .032 .81 .229 CMG Chart 1 U-500 CEC: (Tech Info 500 CMG FT4 Section) U-1000 1000 9423 NEC: 9 See 100 .010 .25 .032 .81 .244 CMG Chart 1 U-500 CEC: (Tech Info 500 CMG FT4 Section) U-1000 1000 8456 NEC: 10 See 100 .010 .25 .032 .81 .264 CMG Chart 1 U-500 CEC: (Tech Info 500 CMG FT4 Section) U-1000 1000 . Final put-up may vary -10% to +20%. May contain two pieces, minimum length of any one piece is 1500 ft. F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 w w w . b e l d e n . c o m M U L T I - C O N D U C T O R C A B L E S Unshielded Audio, Control and Instrumentation Cables Plenum-Rated and Non-Plenum Standard Insulation Jacket UL NEC/ No.

7 Standard Lengths Nominal OD. Color Unit Weight Thickness Thickness Description Part No. C(UL) CEC of Code Type Cond. Ft. m Lbs. kg Inch mm Inch mm Inch mm 22 AWG Stranded (7x30) Tinned Copper Conductors Conductors Cabled (continued). PVC Insulation Chrome PVC Jacket UL AWM Style 2576 8457 NEC: 12 See 100 .010 .25 .032 .81 .272 (150V 80 C) CMG Chart 1 U-500 CEC: (Tech Info 500 CMG FT4 Section) U-1000 1000 NEC: 15 8458 See 100 .010 .25 .040 .315 CMG Chart 2R 500 CEC: (Tech Info 1000 CMG FT4 Section). 9431 NEC: 20 See 100 .010 .25 .040 .345 CMG Chart 2R 500 CEC: (Tech Info 1000 CMG FT4 Section). 8459 NEC: 25 See 100 .010 .25 .040 .387 CMG Chart 2R 500 CEC: (Tech Info 1000 CMG FT4 Section). 9432 NEC: 30 See 100 .010 .25 .040 .400 CMG Chart 2R 500 CEC: (Tech Info 1000 CMG FT4 Section). 9433 NEC: 40 See 100 .010 .25 .040 .455 CMG Chart 2R 500 CEC: (Tech Info 1000 CMG FT4 Section).

8 9434 NEC: 50 See 500 .010 .25 .045 .500 CMG Chart 2R 1000 CEC: (Tech Info CMG FT4 Section). Plenum FEP Insulation Red FEP Jacket 300V RMS, Non-conduit 88442* NEC: 2 Black, 100 .006 .15 .012 .30 .102 CMP Red 500 CEC: 1000 CMP FT6. 300V RMS, Non-conduit 88444 NEC: 4 Black, 100 .006 .15 .010 .25 .121 CMP White, 500 CEC: Red, 1000 CMP FT6 Green Suitable for Outdoor and Direct Burial applications. Plenum FEP Insulation Natural Flamarrest Jacket 300V RMS, Non-conduit 82442* NEC: 2 Black, U-1000 .006 .15 .015 .38 .113 CMP Red 1000 CEC: CMP FT6. 300V RMS, Non-conduit 82444 NEC: 4 Black, U-500 .006 .15 .015 .38 .134 CMP White, U-1000 CEC: Red, 1000 CMP FT6 Green * Twisted Pair Spools and/or UnReel cartons are one piece, but length may vary 10% for spools and 5% for UnReel from length shown. F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 w w w.

9 B e l d e n . c o m M U L T I - C O N D U C T O R C A B L E S Unshielded Audio, Control and Instrumentation Cables Non-Plenum Standard Insulation Jacket UL NEC/ No. Standard Lengths Nominal OD. Color Unit Weight Thickness Thickness Description Part No. C(UL) CEC of Code Type Cond. Ft. m Lbs. kg Inch mm Inch mm Inch mm 20 AWG Stranded (7x28) Tinned Copper Conductors Conductors Cabled PVC Insulation Chrome PVC Jacket UL AWM Style 2464 9444 NEC: 4 See 100 .013 .33 .032 .81 .217 (300V 80 C) CMG Chart 1 U-500 CEC: (Tech Info 500 CMG FT4 Section) U-1000 1000 9445 NEC: 5 See 100 .013 .33 .032 .81 .239 CMG Chart 1 U-500 CEC: (Tech Info 500 CMG FT4 Section) U-1000 1000 9439 NEC: 7 See 100 .013 .33 .032 .81 .260 CMG Chart 1 U-500 CEC: (Tech Info 500 CMG FT4 Section) U-1000 1000 9455 NEC: 9 See 100 .013 .33 .035 .89 .317 CMG Chart 1 500 CEC: (Tech Info 1000 CMG FT4 Section). 9457 NEC: 12 See 100.

10 013 .33 .035 .89 .338 CMG Chart 1 500 CEC: (Tech Info 1000 CMG FT4 Section). 9458 NEC: 15 See 100 .013 .33 .040 .389 CMG Chart 2R 500 4 Multi- Conductor Cables CEC: (Tech Info 1000 CMG FT4 Section). 18 AWG Stranded (19x30) Tinned Copper Conductors Conductors Cabled PVC Insulation Chrome PVC Jacket UL AWM Style 2598 8489 NEC: 4 See 100 .017 .43 .032 .81 .257 (300V 60 C) CMG Chart 1 250 CEC: (Tech Info U-500 For Plenum versions of 8489, CMG FT4 Section) 500 see 88489 or 82489. U-1000 1000 8465 NEC: 5 See 100 .017 .43 .033 .84 .282 CMG Chart 1 U-500 CEC: (Tech Info 500 CMG FT4 Section) U-1000 1000 8467 NEC: 7 See 100 .017 .43 .037 .94 .314 CMG Chart 1 250 CEC: (Tech Info 500 CMG FT4 Section) 1000 8469 NEC: 9 See 100 .017 .43 .037 .94 .364 CMG Chart 1 250 CEC: (Tech Info 500 CMG FT4 Section) 1000 8466 NEC: 12 See 100 .017 .43 .040 .412 CMG Chart 2R 250 CEC: (Tech Info 500 CMG FT4 Section) 1000 8468 NEC: 15 See 100.