1 Made inInnovative and Powerful Deviceto aid in VAP PreventionContinuous subglottiCsuCtion RegulatoR Model PM9100 Continuous subglottiC suCtion RegulatoR Model PM9100 PM9100shown with ball DOWN in NO FLOW positionPM9100shown with ball UP in FLOW positionIt s Innovative: Only unit with the dual capacity of subglottiC and Continuous suCtion . This allows clinicians to meet VAP prevention s Unique: Flow indicator enables the clinician to rapidly assess the patency of the subglottiC suCtion s Powerful: Out performs traditional suCtion regulators at low suCtion pressures used for Continuous subglottiC s Compact: Fits into tight headwall s User Friendly: Easy to read dial & flow of Your Complete Oral Care Solution!PM9100 shown on Left sideRear View showing connection between Vacuum RegulatoR & PM9100PM9100 shown on Right sideVacuum RegulatoR SpecificationsContinuousContinuous-Inter mittentGauge Reading:Gauge Reading:PM3000 & PM31000-200 mmHg and Full Vacuum PM33000-200 mmHg and Full Vacuum Vacuum Operating Range:Vacuum Operating Range:PM3000 & PM31000-200 mmHg and Full Vacuum PM33000-200 mmHg and Full Vacuum Modes:Modes:PM3000 OFF - - OFF - INTPM3100 LINE - OFF - REGS pecifications are subject to change without prior subglottiC suCtion RegulatoR SpecificationsScaled suCtion Range:0 - 85 mmHg (0 kPa)Scale Accuracy:+/- 3 mmHg (.)
2 4 kPa)Maximum RegulatoR Vacuum Setting:85 mmHg ( kPa)Flow:13 lpm @ 20 mmHgup to 37 lpm @ Max of 85 mmHg(54 lpm in Push to Clear mode)Weight (Without Fittings):.38 lb (.17 kg) Dimensions (without fittigs):All specifications obtained using a vacuum source of 21 inHg ( kPa).Specifications are subject to change without prior scale & flows are for reference only.(Verify vacuum pressure setting with PM760 Digital VacCheck)Precision Medical, Held Drive Northampton, PA 18067 Phone: 610-262-6090 Toll-Free Phone: 800-272-7285 Fax: 610-262-6080 Toll-Free Fax: 6/10 Printed in USAO rdering InformationVACUUM SOURCE CONNECTION (on back of unit)1/8 HEXDISS (Old Style)OXEQUIP (Medstar)PURITAN- BENNETTS treet TBOTTOM CONNECTION (inlet)TUBING NIPPLEPM9101PM9102PM9103PM9104PM9105PM91 06PM9107PM9108PM9109 MUST add L or R suffix to all part numbers listed above for Right or Left Source Connection (as viewed from front of device).
3 PM9100 onlyPM9100 with Vacuum RegulatorPart numbers for Vacuum regulators are defined by the basic model number and optional suffixes:PM3 XXXD E HV DBBase ModelNumberSuffixes:Labeling Colorsee chart belowD Digital ModelE Export Model (counter clockwise rotating gauge)HV High Range Vacuum Gauge (0-300mmHg)C Canadian Color Coding of FittingsT includes VacTrap (DISS Male and Ohmeda Style Trap Bottle connections only)VL with Left mounted PM9100VR with Right mounted PM9100 (as viewed from front of device)-DB Dark Blue-Y Yellow-MG Mint Green-P Purple-G Gray-R Red-LB Light BlueVACUUM SOURCE CONNECTION (on back of unit)1/8 HEXDISS (Old Style)OXEQUIP (Medstar)PURITAN- BENNETTBOTTOM CONNECTION (inlet)TUBING NIPPLEPM3001PM3002PM3003PM3004PM3005PM30 06PM3007PM3008PM3101PM3102PM3103PM3104PM 3105PM3106PM3107PM3108PM3301PM3302PM3303 PM3304PM3305PM3306PM3307PM3308 DISS MALEPM3012PM3013PM3014PM3015PM3016PM3017 PM3018PM3019PM3112PM3113PM3114PM3115PM31 16PM3117PM3118PM3119PM3312PM3313PM3314PM 3315PM3316PM3317PM3318PM3319 OHMEDA STYLETRAP BOTTLECONNECTIONPM3023PM3024PM3025PM3026 PM3027PM3028PM3029PM3030PM3123PM3124PM31 25PM3126PM3127PM3128PM3129PM3130PM3323PM 3324PM3325PM3326PM3327PM3328PM3329PM3330