Control Products Catalog CA08102001E August 2010 Relays and TimersD1 Series General Purpose RelayD96 Series Solid-State Relay Universal TR Series Timing Relay Relay Products Control Relays and Timers Comparison .. Series Terminal Block RelaysStandard, OptoCoupler and High Current Catalog Number Selection .. EZ Intelligent RelaysRelays, Modules, Power Supplies, Accessories and Software Product Overview .. General Purpose Plug-In RelaysGeneral Purpose RelaysProduct Selection Guide .. General Purpose Relays Type AA9575H Series 3000 Relay9575H Series 3000 Type AA, AC and DC .. Solid-State RelaysD93, D96 and D99 SeriesProduct Overview .. Machine Tool RelaysFreedom Multipole, Industrial Control , andMultipole with Convertible ContactsProduct Overview.. Timing RelaysUniversal TR, TR and TMR Series Product Selection Guide .. Alternating RelaysD85 SeriesProduct Description ..187 LearnOnline2 Control Products Catalog CA08102001E August 2010 Relays and TimersRelay Product OverviewRelay ProductsContentsDescriptionPageXR Series Terminal Block Relays .

Control Relays and Timers D1 Series General Purpose Relay D96 Series Solid-State Relay Universal TR Series Timing Relay 49.1 Relay Products Control Relays and Timers ...

Tags:

  Control, Early, Timer, Control relays and timers

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Control Relays and Timers - Tri-State Electrical Supply

1 Control Products Catalog CA08102001E August 2010 Relays and TimersD1 Series General Purpose RelayD96 Series Solid-State Relay Universal TR Series Timing Relay Relay Products Control Relays and Timers Comparison .. Series Terminal Block RelaysStandard, OptoCoupler and High Current Catalog Number Selection .. EZ Intelligent RelaysRelays, Modules, Power Supplies, Accessories and Software Product Overview .. General Purpose Plug-In RelaysGeneral Purpose RelaysProduct Selection Guide .. General Purpose Relays Type AA9575H Series 3000 Relay9575H Series 3000 Type AA, AC and DC .. Solid-State RelaysD93, D96 and D99 SeriesProduct Overview .. Machine Tool RelaysFreedom Multipole, Industrial Control , andMultipole with Convertible ContactsProduct Overview.. Timing RelaysUniversal TR, TR and TMR Series Product Selection Guide .. Alternating RelaysD85 SeriesProduct Description ..187 LearnOnline2 Control Products Catalog CA08102001E August 2010 Relays and TimersRelay Product OverviewRelay ProductsContentsDescriptionPageXR Series Terminal Block Relays .

2 3EZ Intelligent Relays .. 19 General Purpose Plug-In Relays .. 42 General Purpose Relays Type AA .. 116 Solid-State Relays .. 120 Machine Tool Relays .. 139 Timing Relays .. 165 Alternating Relays .. 187 Control Relays and Timers Comparison Selection Guide by Catalog Number Prefix RelaysTypeMountingContactsMaximumAmperag e(AC)ULCSACEPageNumber9575H3 General purposePanel mountFixed40A XXX117AR/ARDM achine toolPanel mountConvertible10A XX 152BF/BFDM achine toolPanel mountFixed10AX X 146D2 PFFull featured plug-inDIN rail/panel mountFixed10AX XX53D2 PRStandard plug-inDIN rail/panel mount/flangeFixed10AX XX53D3 PFFull featured plug-inDIN rail/panel mountFixed16AX XX63D3 PRStandard plug-inDIN rail/panel mountFixed16AX XX63D4 PRStandard plug-inDIN rail/panel mountFixed10AX XX72D5 PFFull featured plug-inDIN rail/panel mountFixed16AX XX77D5 PRStandard plug-inDIN rail/panel mount/PC boardFixed16AX XX77D7 PFFull featured plug-inDIN rail/panel mountFixed20AX XX87D7 PRStandard plug-inDIN rail/panel mount/flangeFixed20AX XX88D8 PRStandard plug-inDIN rail/panel mount/flangeFixed30AX XX101D9 PRStandard plug-inPanel mountingFixed25AX X 107D15 Machine toolDIN rail/panel mountFixed10A XXX141D26 Machine toolPanel or channel mountConvertible10A XX 157D85 Alternating relaysDIN rail/panel mountFixed10 AXX

3 X188D1 PFFull featured plug-inDIN rail/panel mountFixed20AX XX47D1 PRStandard plug-inDIN rail/panel mountFixed20AX XX47 EZIntelligent relayDIN railFixed8AX XX21 TMR5 Timing relay (non-programmable)DIN rail/panel mountFixed10 AXX X178 TMR6 Timing relay (non-programmable)DIN rail/panel mountFixed10 AXX X182 TRTiming relay (programmable)DIN rail/panel mountFixed10A XX 175 Universal TRTiming relay (programmable)DIN railFixed8A XXX171 XRTerminal block relayDIN railFixed6A, 10AX X5 Control Products Catalog CA08102001E August 2010 Relays and TimersRelay Product OverviewXR Series Terminal Block Relays ContentsDescriptionPageXR Series Terminal Block Relays Standard Terminal Block Relays .. 4 OptoCoupler Terminal Block Relays .. 12 High Current Terminal Block Relays .. 15XR Series Accessories .. 18 Catalog Number Selection XR Series Overview DescriptionXR =XR terminal block relayXRU1D12 GPoles1 = 1 PDT2 = 2 PDTC onnection TypeU = ScrewP = SpringR = Replacement relayGold-Flashed ContactsBlank= NoG = YesTypeD = Standard Relays = Octocoupler (solid-state)H = High currentVoltage12 = 12 Vdc24 = 24 Vdc24U = 24 Vac/Vdc120U = 120 Vac/110 Vdc230U = 230 Vac/220 Vdc4 Control Products Catalog CA08102001E August 2010 Relays and TimersXR Series Terminal Block RelaysStandard Terminal Block RelayContentsDescriptionPageStandard Terminal Block RelaysProduct Selection.

4 5 Technical Data and Specifications .. 6 Electrical Schematics .. 11 Dimensions .. 11 OptoCoupler Terminal Block Relays .. 12 High Current Terminal Block Relays .. 15XR Series Accessories .. 18 Standard Terminal Block RelaysProduct DescriptionThe XR Series Terminal Block Relays are ideal for applications that require a high switching capacity and long Electrical service life. The Relays are plug-in interfaces that connect to basic terminal blocks. The XR Series uses screw or spring-cage technology, as well as offers quick system wiring, superior safety features, clear labeling and a high level of modularity. Application DescriptionUsed in automation systems, electromechanical Relays guarantee a safe connection between process I/O and electronic controls. The following functions are covered by relay coupling elements: Electrical isolation between the input and output circuits Independence of the type of switching current (AC and DC) High short-term overload resistance in the event of short circuits or voltage peaks Low switching losses Ease of operationFeatures Pluggable relay allows for field replacement Functional plug-in bridges Choice of screw connections or spring-cage connection LED status indication DIN rail mount Only mm wide for single-pole versions, 14 mm wide for double-pole All common input voltages between 12 Vdc to 120 Vac Gold-plated contacts available Equipped with a robust, miniature relay.

5 IP67 protection Environmentally friendly, cadmium-free contact material Easy, cost-effective installation and replacement using the engagement leverStandards and Certifications cULus listed CE Control Products Catalog CA08102001E August 2010 Relays and TimersXR Series Terminal Block RelaysProduct SelectionStandard Terminal Block Relays Standard Replacement Relays Gold-Plated ContactsRatedCurrentSupplyVoltageStandar dPackCatalogNumber1 PDT Screw ConnectionNo6A12 Vdc10 XRU1D12No6A120 Vac/110 Vdc10 XRU1D120 UYes6A120 Vac/110 Vdc10 XRU1D120 UGNo6A24 Vdc10 XRU1D24No6A24 Vac/Vdc10 XRU1D24 UYes6A24 Vac/Vdc10 XRU1D24 UGNo6A230 Vac/220 Vdc10 XRU1D230U1 PDT Spring Cage ConnectionNo6A12 Vdc10 XRP1D12No6A120 Vac/110 Vdc10 XRP1D120 UNo6A24 Vdc10 XRP1D24No6A24 Vac/Vdc10 XRP1D24 UNo6A230 Vac/220 Vdc10 XRP1D230 UDPDT Screw ConnectionNo6A12 Vdc10 XRU2D12No6A120 Vac/110 Vdc10 XRU2D120 UNo6A24 Vdc10 XRU2D24No6A24 Vac/Vdc10 XRU2D24 UNo6A230 Vac/220 Vdc10 XRU2D230 UGold-Plated ContactsRatedCurrentSupplyVoltageStandar dPackCatalogNumber1 PDTNo6A12 Vdc10

6 XRR1D12No6A120 Vac/110 Vdc10 XRR1D120 UYes6A120 Vac/110 Vdc10 XRR1D120 UGNo6A24 Vdc10 XRR1D24 Yes6A24 Vdc10 XRR1D24 GNo6A230 Vac/220 Vdc10 XRR1D230 UDPDTNo6A12 Vdc10 XRR2D12No6A120 Vac/110 Vdc10 XRR2D120 UNo6A24 Vdc10 XRR2D24No6A230 Vac/220 Vdc10 XRR2D230 UXRU1D 24U6 Control Products Catalog CA08102001E August 2010 Relays and TimersXR Series Terminal Block RelaysTechnical Data and SpecificationsStandard 1 PDT Screw Connection Terminal Block Relays Note The separating plate, XRAPLCESK, should be installed for voltages greater than 250V (L1, L2, L3) between identical terminal points of adjacent modules. Potential bridging is then possible with the XRAFBST bridge NumberXRU1D12 XRU1D24 XRU1D24 UXRU1D120 UReplacement RelayXRR1D12 XRR1D24 XRR1D24 XRR1D120 UInput voltage12 Vdc24 Vdc24 Vac/Vdc120 Vac/110 VdcConnection DataRigid solid AWG (mm2)26 14 ( )26 14 ( )26 14 ( )26 14 ( )Flexible stranded AWG (mm2)26 14 ( )26 14 ( )26 14 ( )26 14 ( )Input Data for 1 PDT Screw Connection VersionsInput voltage12 Vdc24 Vdc24 Vac/Vdc120 Vac/110 VdcPermissible range See Page 10 See Page 10 See Page 10 See Page 10 Typical input mA9 mA11 mA (24 Vac) mA (24 Vdc) mA (120 Vac)/3 mA (110 Vdc)Typical response time5 ms5 ms6 ms6 msTypical release time8 ms8 ms15 ms15 msInput protectionPolarity protection diode, free-wheeling diodePolarity protection diode, free-wheeling diodeBridge rectifierBridge rectifierOutput DataContact type1 PDT1 PDT1 PDT1 PDTC ontact materialAgSnOAgSnOAgSnOAgSnOMax.

7 Switching voltage250 Vac/Vdc 250 Vac/Vdc 250 Vac/Vdc 250 Vac/Vdc Min. switching voltage12 Vac/Vdc12 Vac/Vdc12 Vac/Vdc12 Vac/VdcLimiting continuous current6A6A6A6 AMin. switching current10 mA10 mA10 mA10 mAMin. switching power120 mW120 mW120 mW120 mWMiscellaneous DataAmbient temp range 4 to 140 F ( 20 to 60 C) 4 to 140 F ( 20 to 60 C) 4 to 140 F ( 20 to 60 C) 4 to 140 F ( 20 to 60 C)Rated operating mode100% operating factor100% operating factor100% operating factor100% operating factorInflammability classV0, in accordance with UL 94V0, in accordance with UL 94V0, in accordance with UL 94V0, in accordance with UL 94 Mechanical service life2 x 107 cycles2 x 107 cycles2 x 107 cycles2 x 107 cyclesControl Products Catalog CA08102001E August 2010 Relays and TimersXR Series Terminal Block RelaysStandard 1 PDT Screw Connection Terminal Block Relays with Gold Contacts Notes The separating plate, XRAPLCESK, should be installed for voltages greater than 250V (L1, L2, L3) between identical terminal points of adjacent modules.

8 Potential bridging is then possible with the XRAFBST bridge system. If the maximum values are exceeded, the gold layer is destroyed and the values in parentheses NumberXRU1D24 UGXRU1D120 UGReplacement RelayXRR1D24 GXRR1D120 UGInput voltage24 Vac/Vdc120 Vac/110 VdcConnection DataRigid solid AWG (mm2)26 14 ( )26 14 ( )Flexible stranded AWG (mm2)26 14 ( )26 14 ( )Input Data for 1 PDT Screw Connection Versions with Gold ContactsInput voltage24 Vac/Vdc120 Vac/110 VdcPermissible range See Page 10 See Page 10 Typical input current11 mA (24 Vac) mA (24 Vdc) mA (120 Vac)/3 mA (110 Vdc)Typical response time6 ms6 msTypical release time15 ms15 msInput protectionBridge rectifierBridge rectifierOutput DataContact type1 PDT1 PDTC ontact materialAgSnO, gold plated AgSnO, gold plated Max. switching voltage30 Vac/36 Vdc (250 Vac/Vdc) 30 Vac/36 Vdc (250 Vac/Vdc) Min. switching voltage100 mV (12 Vac/Vdc) 100 mV (12 Vac/Vdc) Limiting continuous current50 mA (6A) 50 mA (6A) Min.

9 Switching current1 mA (10 mA) 1 mA (10 mA) Min. switching power100 mW (120 mW) 100 mW (120 mW) Miscellaneous DataAmbient temp range 4 to 140 F ( 20 to 60 C) 40 to 131 F ( 20 to 55 C)Rated operating mode100% operating factor100% operating factorInflammability classV0, in accordance with UL 94V0, in accordance with UL 94 Mechanical service life2 x 107 cycles2 x 107 cycles8 Control Products Catalog CA08102001E August 2010 Relays and TimersXR Series Terminal Block RelaysStandard 1 PDT Spring Cage Terminal Block Relays Note The separating plate, XRAPLCESK, should be installed for voltages greater than 250V (L1, L2, L3) between identical terminal points of adjacent modules. Potential bridging is then possible with the XRAFBST bridge NumberXRP1D12 XRP1D24 XRP1D24 UXRP1D120 UReplacement RelayXRR1D12 XRR1D24 XRR1D24 XRR1D120 UInput voltage12 Vdc24 Vdc24 Vac/Vdc120 Vac/110 VdcConnection DataRigid solid AWG (mm2)26 14 ( )26 14 ( )26 14 ( )26 14 ( )Flexible stranded AWG (mm2)26 14 ( )26 14 ( )26 14 ( )26 14 ( )Input Data for 1 PDT Spring Cage VersionsInput voltage12 Vdc24 Vdc24 Vac/Vdc120 Vac/110 VdcPermissible range See Page 10 See Page 10 See Page 10 See Page 10 Typical input mA9 mA11 mA (24 Vac) mA (24 Vdc) mA (120 Vac)/3 mA (110 Vdc)Typical response time5 ms5 ms6 ms6 msTypical release time8 ms8 ms15 ms15 msInput protectionPolarity protection diode, free-wheeling diodePolarity protection diode, free-wheeling diodeBridge rectifierBridge rectifierOutput DataContact type1 PDT1 PDT1 PDT1 PDTC ontact materialAgSnOAgSnOAgSnOAgSnOMax.

10 Switching voltage250 Vac/Vdc 250 Vac/Vdc 250 Vac/Vdc 250 Vac/Vdc Min. switching voltage12 Vac/Vdc12 Vac/Vdc12 Vac/Vdc12 Vac/VdcLimiting continuous current6A6A6A6 AMin. switching current10 mA10 mA10 mA10 mAMin. switching power120 mW120 mW120 mW120 mWMiscellaneous DataAmbient temp range 4 to 140 F ( 20 to 60 C) 4 to 140 F ( 20 to 60 C) 4 to 140 F ( 20 to 60 C) 4 to 131 F ( 20 to 55 C)Rated operating mode100% operating factor100% operating factor100% operating factor100% operating factorInflammability classV0, in accordance with UL 94V0, in accordance with UL 94V0, in accordance with UL 94V0, in accordance with UL 94 Mechanical service life2 x 107 cycles2 x 107 cycles2 x 107 cycles2 x 107 cyclesControl Products Catalog CA08102001E August 2010 Relays and TimersXR Series Terminal Block RelaysStandard DPDT Screw Connection Terminal Block Relays Note The separating plate, XRAPLCESK, should be installed for voltages greater than 250V (L1, L2, L3) between identical terminal points of adjacent modules.