Transcription of ControlLogix Digital I/O Modules User Manual
1 ControlLogix Digital I/O ModulesCatalog Numbers 1756-IA8D, 1756-IA16, 1756-IA16I, 1756-IA32, 1756-IB16, 1756-IB16D, 1756-IB16I, 1756-IB16IF,1756-IB32, 1756-IC16, 1756-IG16, 1756-IH16I, 1756-IM16I, 1756-IN16, 1756-IV16, 1756-IV32, 1756-OA8, 1756-OA8D, 1756-OA8E, 1756-OA16, 1756-OA16I, 1756-OB8, 1756-OB8EI, 1756-OB8I, 1756-OB16D, 1756-OB16E, 1756-OB16I,1756-OB16 IEF, 1756-OB16 IEFS, 1756-OB16IS, 1756-OB32, 1756-OC8, 1756-OG16, 1756-OH8I, 1756-ON8, 1756-OV16E, 1756-OV32E, 1756-OW16I, 1756-OX8 IUser ManualOriginal InstructionsImportant User InformationRead this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product.
2 Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this examples and diagrams in this Manual are included solely for illustrative purposes.
3 Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this of the contents of this Manual , in whole or in part, without written permission of Rockwell Automation, Inc., is prohibitedThroughout this Manual , when necessary, we use notes to make you aware of safety may also be on or inside the equipment to provide specific precautions.
4 WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic : Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the information that is critical for successful application and understanding of the HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous voltage may be HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may reach dangerous FLASH HAZARD.
5 Labels may be on or inside the equipment, for example, a motor control center, to alert people to potential Arc Flash. Arc Flash will cause severe injury or death. Wear proper Personal Protective Equipment (PPE). Follow ALL Regulatory requirements for safe work practices and for Personal Protective Equipment (PPE).Rockwell Automation Publication 1756-UM058I-EN-P - December 20173 Table of ContentsPreface ..9 Summary of Changes .. 9 Product Compatibility and Download Center .. 9 Additional Resources .. 10 Chapter 1 What Are ControlLogix Digital I/O Modules ?
6 Available Features .. 11I/O Modules in the ControlLogix System .. 12 module Identification and Status Information.. 15 Chapter 2 Digital I/O Operation in the ControlLogix SystemOwnership .. 181756-OB16 IEF Redundant Owner .. 18 Internal module Operation .. 18 Input Modules .. 19 Output Modules .. 20 Connections .. 21 Direct Connections.. 21 Rack-optimized Connections.. 22 Suggestions for Rack-optimized Connections .. 23 Input module Operation .. 23 Input Modules in a Local Chassis .. 24 RPI.. 24 COS .. 24 Trigger Event Tasks.
7 25 Input Modules in a Remote Chassis.. 25 Remote Input Modules Connected via the ControlNet Network .. 26 Remote Input Modules Connected via the EtherNet/IP Network.. 27 Output module Operation.. 28 Output Modules in a Local Chassis .. 28 Output Modules in a Remote Chassis .. 29 Remote Output Modules Connected via the ControlNet Network .. 29 Remote Output Modules Connected via the EtherNet/IP Network.. 30 Listen-only Mode .. 31 Multiple Owner-Controllers of Input Modules .. 31 Configuration Changes in an Input module with Multiple Owners.
8 324 Rockwell Automation Publication 1756-UM058I-EN-P - December 2017 Table of ContentsChapter 3 Common module FeaturesInput module Compatibility .. 35 Output module Compatibility .. 36 Common Features .. 37 Removal and Insertion Under Power .. 37 module Fault Reporting .. 37 Software Configurable .. 38 Electronic Keying.. 38 module Inhibiting .. 39 Use the System Clock to Timestamp Inputs and Schedule Outputs .. 40 Producer/Consumer Communication .. 44 Status Indicator Information .. 44 Common Features Specific to Input Modules .
9 44 Data Transfer on Either Cyclic Time or Change of State.. 45 Set RPI .. 45 Enable Change of State .. 46 Software Configurable Filter Times .. 47 Isolated and Nonisolated Varieties of Input Modules .. 47 Multiple Input Point Densities .. 48 Common Features Specific to Output Modules .. 48 Configurable Point-level Output States .. 49 Output Data Echo.. 50 Isolated and Nonisolated Varieties of Output Modules .. 50 Multiple Output Point Densities .. 51 Electronic Fusing .. 51 Field Power Loss Detection.. 54 Diagnostic Latch of Information.
10 55 Time-scheduled Output Control .. 57 Fault and Status Reporting between Input Modules and Controllers .. 58 Fault and Status Reporting between Output Modules and Controllers .. 59 Fuse Blown Bit per Point.. 60 Rockwell Automation Publication 1756-UM058I-EN-P - December 20175 Table of ContentsChapter 4 Diagnostic module FeaturesDiagnostic Input module Compatibility .. 61 Diagnostic Output module Compatibility .. 62 Diagnostic Features .. 62 Diagnostic Latch of Information.. 62 Diagnostic Timestamp .. 638-Point AC/16-Point DC.