Example: bachelor of science

COOPER LIGHTING - METALUX

LAMP CONFIGURATIONSCOOPER LIGHTING - METALUX Catalog #TypeDateProjectCommentsPrepared byLAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL,STATE OR FEDERAL LAWSSafe and convenient means ofdisconnecting " [603mm]3-1/4"[83mm] COOPER LIGHTINGDESCRIPTIONThe GR8-IC is a T8-dedicated lensed troffer designed to offer premiumperformance in a low profile housing. T8 dedication and optimizedlamp to lens spacing provides the best in energy efficiency and opticalcontrol. The GR8-IC s shallow, low profile housing is compatible witheven highly restrictive plenums. Luminaires are compatible with today spopular ceiling GR8-IC offers great performance and great quality.

LAMP CONFIGURATIONS COOPER LIGHTING - METALUX® Catalog # Type Date Project Comments Prepared by LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS

Tags:

  Lighting, Cooper, Cooper lighting

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of COOPER LIGHTING - METALUX

1 LAMP CONFIGURATIONSCOOPER LIGHTING - METALUX Catalog #TypeDateProjectCommentsPrepared byLAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL,STATE OR FEDERAL LAWSSafe and convenient means ofdisconnecting " [603mm]3-1/4"[83mm] COOPER LIGHTINGDESCRIPTIONThe GR8-IC is a T8-dedicated lensed troffer designed to offer premiumperformance in a low profile housing. T8 dedication and optimizedlamp to lens spacing provides the best in energy efficiency and opticalcontrol. The GR8-IC s shallow, low profile housing is compatible witheven highly restrictive plenums. Luminaires are compatible with today spopular ceiling GR8-IC offers great performance and great quality.

2 The series is anexcellent choice for commercial offices, schools, hospitals, retailmerchandising and many other Ballast & STD Lamps228T8 (49), 232 (61)428T8 (98), 432 (122)Luminaire Efficacy RatingLER = FL-82 Catalog Number:2GR8-232 AYearly Cost of 1000 lumens,3000 hrs at .08 KWH = $ Number:2GR8-432 ALER = FL-76 Yearly Cost of 1000 lumens,3000 hrs at .08 KWH= $ *Standard G (Grid) Type Fixtures can befield converted by adding trim kits. SeeCompatibility Section or Consult Factory.**Reference the lamp/ballast data in theTechnical Section for specific lamp/ballastrequirements.**When ordering Flange Kit forinstallation in drywall ceilings, see optionsand accessories compatibility section andordering logic.

3 2GR8-IC228T8, 232428T8, 4322' X 4' TROFFER2 OR 4 LAMPG eneral Purpose T8 Commercial TrofferFor Use in Insulated Ceiliings ADF122070 ENERGY DATA Input Watts:SPECIFICATION FEATURESC onstructionUnitized low profile recessedhousing is die formed of codegauge prime cold rolled steel withfull length stiffeners and unibodyendplate for added cover is easily removedwithout tools. Die formed captivelampholder bracket fully encloseslampholder wiring for easylampholder replacement. AmpleKOs are provided for continuousrow wiring. Built-in grid-lockfeature for safety and convenience. Electrical**Ballasts are CBM/ETL Class P and are positively secured bymounting bolts.

4 Rotor-locklampholders. UL/CUL listed. ICrecessed luminaire for directcontact with insulation. Suitablefor damp , iron phosphatepretreatment ensures maximumbonding and rust grade baked whiteenamel finish with premiumreflectance for high spring loaded steellatches and safety lock T-hingesprovide secure, high quality doorfit and allow hinging and latchingfrom either "[603mm]47-15/16" [1218mm]3-1/2"[89mm]1"[26mm]1-1/2"[38mm] 1-1/2" [38mm]3-1/8"[80mm]Location of StandardAccess Opening23-3/4" [603mm]3-1/4" [83mm]10-3/4" [274mm]2 LAMP4 LAMP23-3/4" [603mm]3-1/4" [83mm]X=4-3/16" [107mm]Y=4-3/4" [121mm]XYXMOUNTING DATAF rame/ShieldingHeavy gauge flat steel door is dieformed with reinforced miteredcorners.

5 Housing and door frameassemblies incorporate full widthmechanical light traps. Lightstabilized, acrylic prismatic Light ballast options areoffered for both 0-10 Vcontinuous dimming and DALI applications. Combine withenergy-saving products likeoccupancy sensors, daylightingcontrols, and LIGHTING relaypanels from COOPER Controls( ) tomaximize energy COMPATIBILITYGGrid/Lay-inStandardGConcea led TGSlot GridFFlange TrimWith SupportingSwing GatesCeilingTrimTypeTypeExposed GridGConcealed TGSlot GridGFlangeG**DOOR FRAMES2GR8F lat, White St eel ( W h i t e Latches)2GR8-ICADF122070 Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 4/13 Visit our web site at of UtilizationEffective floor cavity reflectance20%rc80%70%50%30%10%0%rw70 50 30 1070 50 30 1050 30 1050 30 1050 30 100 RCR012345678910 Typical VCP PercentagesHeight AlongHeight AcrossRoom Size (Ft.)

6 20 x 2030 x 3030 x 6060 x 3060 x 60 Zonal Lumen SummaryZoneLumens%Lamp%Fixture0-300-400- 600-900-180 CandelaAngleAlong II45 Across 0510152025303540455055606570758085902GR8 IC-232 AElectronic BallastF32T8/35K lamps2800 lumensSpacing criterion:(II) x mountingheight, ( ) xmounting heightEfficiency = FL-67 Yearly Cost of 1000lumens, 3000 hrs KWH = $ 095 95 95 9593 93 93 9389 89 8985 85 8581 81 818088 85 82 7986 83 80 7879 77 7576 74 7373 72 716981 75 70 6679 74 69 6671 67 6468 65 6366 64 616075 67 62 5773 66 61 5664 59 5562 58 5560 56 545269 60 54 4967 59 53 4957 52 4856 51 4754 50 474563 54 47 4262 53 47 4251 46 4250 45 4148 44 413958 48 42 3757 48 41 3746 41 3645 40 3644 39 363454 44 37 3253 43 37 3242 36 3241 35 3240 35

7 313050 39 32 2848 39 32 2838 32 2837 31 2836 31 272646 35 29 2445 35 28 2434 28 2433 28 2432 27 242242 32 26 2141 31 25 2131 25 2130 25 2129 24 2120 First Center 1121 Highway 74 South Peachtree City, GA 30269 4/13 Visit our web site at :(1)An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required perfixture. (2)Products also available in non-US voltages and frequencies for international markets.(3)Not available when specifying emergencies, voltage must be specific. (4)Ballast Factor is for4 lamp 32W T8 fixtures.

8 (5)For a complete listing of Fifthlight Technology products and other solutionsfrom COOPER Controls, visit (6)0-10V ballast do not include DALI select DALI ballast for use with Fifth Light system. (7)Specification grade 0-10V dimming ballastare NEMA premium and CEE listed. They are compatible with low mercury and energy saving lamps.(8)Specification Grade 0-10V ballast not offered in 3 or 4-lamp versions. (9)Standard 0-10V ballast notavailable for 28W T8 lamps. (10)Voltage must be specified for Standard 0-10V 32W 3 and 4-lamp ballast versions must be complete product data, reference the Fluorescent Specification binder.

9 Specifications &dimensions subject to change without notice. Consult your COOPER LIGHTING Representative foravailability and ordering INFORMATIONSAMPLE NUMBER: 2GR8-IC-232A-UNV-EB81-UNumber ofLamps2=2 Lamps4=4 Lamps(Not included)Wattage28T8=28W T8 (48")32=32W T8 (48")(4)ShieldingA=#12 Acrylic PatternA125=#12 PatternAcrylic (.125" Thick)A19/156=#19 PatternAcrylic (.156" Thick)PB1S=Silver ParabolicLouver (1/2" x 1/2" x 1/2")OptionsGL=Single Element FuseGM=Double Element FuseFlex=Flex Installed(Reference Flex orderinginformation)EL=Emergency InstalledPackagingU=Unit PackWidth2=2' WidthSeriesR8=General PurposeT8 CommercialTroffer(1)Trim TypeG=Grid/Lay-in(Standard)Voltage (2)347V=347 VoltUNV=UniversalVoltage 120-277(3)2GR8-IC-228T8A20 lbs.

10 SHIPPING INFORMATIONC atalog Safety Earthquake Clips(1)FCTKA-24W-U=Field Installed Flange KitTrim KitFieldConvertibleAluminumFCTKA 22=2' x 2'24=2' x 4'24 Blank=SingleR=In RowE=End RowRWN=NaturalW=White UU=Unit PackBallast TypeEB8 =T8 Electronic Start. Total Harmonic Distortion < 10%EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10%.High Ballast Factor > = T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%High Performance T8 BallastsHB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 .88HB8 L=T8 Electronic Instant Start.


Related search queries