Catalog #ProjectCommentsPrepared byTypeDate* Additional Warranty Details Upon RequestABCH eightWidthDepthABC47"30"25" lifeway IISINGLE PHASE CSERIESS pecifications and dimensions subject to change without your representative for additional options and LIGHTING - SURE-LITES The SURE-LITES lifeway II C Series is a single phase inverter that providesuninterrupted power. This pulse width modulated inverter utilizes IGBT technology and has a 2 millisecond transfer time. The unit's operatingefficiency is 98%, well above a typical fast transfer inverter. The C Seriesinverter is UL 924 listed and meets NFPA 101 requirements by providing90 minutes of illumination for emergency egress LIGHTING .

Catalog # Project Comments Prepared by Type Date *AdditionalWarranty Details Upon Request A B C Height Width Depth ABC 47" 30" 25" LIFEWAY II SINGLE PHASE C

Tags:

  User, Ielts, Sure lites, Lifeway

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of COOPER LIGHTING - SURE-LITES

1 Catalog #ProjectCommentsPrepared byTypeDate* Additional Warranty Details Upon RequestABCH eightWidthDepthABC47"30"25" lifeway IISINGLE PHASE CSERIESS pecifications and dimensions subject to change without your representative for additional options and LIGHTING - SURE-LITES The SURE-LITES lifeway II C Series is a single phase inverter that providesuninterrupted power. This pulse width modulated inverter utilizes IGBT technology and has a 2 millisecond transfer time. The unit's operatingefficiency is 98%, well above a typical fast transfer inverter. The C Seriesinverter is UL 924 listed and meets NFPA 101 requirements by providing90 minutes of illumination for emergency egress LIGHTING .

2 Other runtimes and voltages are available. Please consult your COOPER FEATURESE lectrical- Input 120 or 277 VAC 1 phase 2 wire- Output 120 or 277 VAC1 phase- Output load power factor lag to lead- Electronic and magnetic ballast compatible- Output distortion lessthan 3% THD for linear loads- Forced air cooling only during emergency operation, no filters required- Generator compatibility- 90 minute runtime standard; other runtimes available upon request- Custom voltages available- Supports LED and HID LightingStandard Features- 98% efficient- PWM/IGBT technology- Micro-processor control- user programmable with password protection- Self Testing and Self Diagnostic with Event, Test and Alarm Logs (includes 5 minute monthly test and 90 minute annual test)- RS232 communications port- Input circuit breaker- Modular design- Low audible noiseCode Compliance- UL 924 Listed Application - HID, Fluorescent and Incandescent LightingWarranty- Limited Manufacturer's One(1)

3 Year Warranty On All Electronics*- Limited Manufacturer's Two (2) Year Warranty On All Electronics with Start-Up Service*- Limited Manufacturer's Battery Warranty: One (1) Year Full Value Warranty/9 Years Pro-RataDESCRIPTIONS ingle Phase, UPSHIDF luorescentIncandescentSchoolsCollegesPri sonsIndustrialCasinosOfficesShopping MallsMilitary ComplexesAirportsRailway & TransitSports FacilitiesFAA911 FacilitiesHotels & MotelsHospitalsRace TracksADX052052 pc2010-08-19 17:00 - KVAHIDFLUORESCENTINCANDESCENT2010-08-09 14:08:49 ORDERING INFORMATION Voltage Input120277 Voltage Output120277 SeriesISCS ingle Pase C=KVA *See Optional Features on.

4 Specifications and dimensions subject to change without Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 TEL FAX Electronics ModuleBattery ModuleAC InputPower Rating(kVA)Power Rating(kW)Efficiency (@ full load)Voltage (VDC)Audible Noise(dBA @ 1m)1 Number ofCurrent (Amperes)Number ofHeat Loss(BTU)BatteriesRun Time (mins)Battery CabinetsCabinet DimensionsCabinet DimensionsthgieWhtpeDthgieHhtdiWthgieWla toTthgieWhtpeDthgieHhtdiWmumixaMgninnuRm umixaMgninnuRgk/sblmc/nimc/nimc/nigk/sbl gk/sblmc/nimc/ 457530/7747/120 25/64250/114296/13544839 45 100 30/7747/120 25/64 265/121444/20267238 45 160 30/7747/120 25/64 295/134592/26989638 45 200 30/7747/120 25/64 305/139740/33610 120 37 45 245 30/7747/120 25/64 315/143888/40312 144 40 47/120 25/64210 25/64232/106130/7747/120 25/64420/191230/77

5 47/120 25/64420/191230/77 47/120 25/64464 #ISC015 ISC022 ISC030 ISC037 ISC048 ISC060 ISC080 ISC100 ISC125 ISC167 Input:Voltage120 or 277 VAC 1-phase 2-wire +10% - 15%. Contact factory for all other PowerWalk-in Limiting inrush current to less than 125%, 10 times for 1 line cycleInput Frequency60Hz, +/-3%Synchronizing Slew Rate1Hz per second nominalProtectionInput Circuit BreakerHarmonic Distortion<10%Power lag/leadOutput:Voltage120 or 277 VAC 1-phase 2-wire. Contact factory for all other VoltageLoad current change +/-2%, battery discharge + Voltage+/-2% for +/-25% load step change, +/-3% for a 50% load step change, recovery within 3 cyclesHarmonic Distortion<3% THD for linear loadOverloadFuse protectedOutput Frequency60Hz +/- during emergency modeLoad Power lag to leadInverter Overload125% for 5 minutesProtectionOptional Distribution Circuit BreakersBattery:TypeValve-regulated sealed lead calcium (standard).

6 ChargerMicroprocessor controlled for various battery types and temperature compensating (recharge per UL924 spec)ProtectionAutomatic low-battery disconnect; automatic restart upon utility RuntimesExtended runtimes available. Environmental:Altitude<10,000 feet (above sea level) without de-ratingOperating TemperatureSystem operates safely from 0 to 40 C (32 to 104 F) up to 95% humidity. UL rating, 20 to 30 C (68 to 86 F)includes battery performance which can be affected by temperature. Contact factory for Temperature-20 to 70 Celsius (electronics only)Relative Humidity<95% (non-condensing)General:DesignStandy-by no break.

7 PWM inverter type utilizing IGBT technology with 2mS transfer InputCompatible with generatorsControl InputMicroprocessor controlled 2 x 20-character display with touch pad controls & functions5 LED indicators & alarm with ring-back featureMeteringInput & Output Voltage, Battery Voltage, Battery & Output Current, Output VA, Temperature, Inverter WattageAlarmsHigh/Low Battery Charger Fault, Near Low Battery, Low Battery, Load Reduction Fault, Output Overload,High/Low AC Input Volts, High Ambient Temperature, Inverter Fault, Output Fault, Optional Circuit Breaker TripCommunicationsRS-232 port (DB9) Manual Maintenance BypassOptional internal or optional external without internal distribution ContactsOptional Summary Form C ContactsWarranty1 year standard warranty includes all parts, labor, & travel expenses within 48 contiguous states.

8 Up to 10 yearsprorated warranty on Start-upPurchase factory start-up & receive 1 additional year of Features:Auto Dialer, Battery Charger Upgrade, Dimming Bypass Relay, Extended Factory Warranty, Factory Startup andTraining, Fax/Modem, Maintenance Bypass Switch, Normally Off Output, Output Circuit Breakers, Output Trip Alarms,Remote Meter Panel, Remote Summary Alarm Panel, Seismic Mounting, Summary Alarm Dry Contact, SummaryForm C Contacts, and Variable Time :CabinetFreestanding NEMA Type 1 CoolingForced Air, during emergency modeCable EntryTop or sideAccessFrontBatteriesSPECIFICATION DATAADX052052 pc2010-08-19 17:00:03 lifeway II SINGLE PHASE C SERIES2010-08-09 14:08:49